• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BJ07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BJ07-5AV0 WinCC flexible 2007

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BJ07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BJ07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing human-machine interface (HMI) applications used in conjunction with Siemens SIMATIC HMI panels. It belongs to the WinCC flexible 2007 generation, which represents a key milestone in Siemens' HMI engineering platform evolution.

    WinCC flexible 2007 offers a comprehensive set of engineering tools for creating HMI visualizations, including drag-and-drop screen design, tag management, alarm logging, and trend displays. The software supports a wide range of Siemens HMI hardware targets, including the OP, TP, MP, and Mobile Panel series. It provides communication drivers for SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). The platform also supports recipe management, user administration, and multi-language project configuration.

    WinCC flexible 2007 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, water treatment, and process industries. It is particularly suited for machine-level HMI applications where operators require real-time process visualization, alarm management, and data logging. The software is typically deployed on engineering workstations running Windows XP or Windows Vista for project configuration and download to target HMI devices.

    Technical Specifications

    Software Version WinCC flexible 2007
    Software Type Engineering Software / HMI Configuration Tool
    Supported HMI Devices SIMATIC OP, TP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (PROFINET)
    Operating System Windows XP, Windows Vista
    License Type Single-user software license
    Series/Product Family WinCC flexible
    Language Support Multi-language project configuration
    Alarm Management Integrated alarm logging and display
    Data Logging Trend display and recipe management supported
    User Administration Integrated user and role management

    Common Error Codes & System Events

    Error 1
    License not found or invalid license key detected during startup
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall the license if necessary.
    Error 2
    Communication error between engineering PC and HMI target device during project download
    Check the physical connection (MPI cable, PROFIBUS connector, or Ethernet cable). Verify correct communication parameters (baud rate, station address) in the project settings.
    Error 3
    Incompatible project version detected when opening an existing WinCC flexible project
    Check the software version used to create the project. Use the project migration wizard within WinCC flexible to convert the project to the 2007 version format.
    Error 4
    HMI device type mismatch — project configured for a different panel than the connected target
    Open the project properties and verify the selected HMI device type matches the physical hardware. Use 'Change Device Type' function if migration is required.
    Error 5
    Runtime download failed due to insufficient memory on the target HMI device
    Reduce the project size by optimizing graphics, reducing the number of tags, or compressing images. Check available flash memory on the target panel.
    Error 6
    Tag limit exceeded for the selected runtime license tier
    Verify the number of configured tags against the licensed tag count for the installed runtime version. Upgrade the runtime license if additional tags are required.
    Error 7
    Compilation error during project build due to invalid or missing tag references
    Open the cross-reference list in WinCC flexible to identify all invalid tag references. Correct or reassign the affected tags before recompiling the project.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of Siemens SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel 177 series, among others. The exact list of supported devices is specified in the WinCC flexible 2007 compatibility documentation.

    Which PLCs can communicate with HMI projects configured in WinCC flexible 2007?

    WinCC flexible 2007 supports communication with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). Third-party PLC communication may be possible via OPC or specific driver packages.

    Is WinCC flexible 2007 compatible with Windows 10?

    WinCC flexible 2007 was designed for Windows XP and Windows Vista and is not officially supported on Windows 10. For modern operating systems, Siemens recommends migrating to TIA Portal with WinCC.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, manual adjustments are typically required after migration due to differences in functionality and device support.

    What is the Automation License Manager (ALM) and is it required?

    The Siemens Automation License Manager is a tool used to manage software licenses for Siemens engineering software, including WinCC flexible. It must be installed and a valid license must be present for WinCC flexible 2007 to operate in full engineering mode.

    Troubleshooting

    WinCC flexible 2007 fails to start and displays a license error

    Check the Automation License Manager (ALM) to verify whether a valid license for WinCC flexible 2007 is present and correctly assigned to the local machine or USB dongle.

    Reinstall the license using the ALM tool. If using a USB license key, ensure it is properly connected. Contact Siemens support if the license appears valid but the error persists.

    Project download to HMI panel fails or times out

    Verify the physical communication link between the engineering PC and the HMI panel. Check that the correct communication interface (MPI, PROFIBUS, or Ethernet) and parameters are configured in both the project and the panel settings.

    Correct any mismatched communication parameters such as baud rate or station address. Replace the communication cable if faulty. Ensure the HMI panel is in transfer mode before initiating the download.

    Compiled project size exceeds available memory on the target HMI panel

    Review the project compilation report for memory usage details. Identify large graphic files, excessive tag counts, or redundant screens contributing to the project size.

    Optimize images by reducing resolution or color depth, remove unused tags and screens, and compress graphic resources. Consider upgrading to a higher-memory HMI panel if the project requirements cannot be reduced.

    Tags are not updating on the HMI runtime display

    Check the communication status indicator on the HMI panel runtime. Verify that the PLC is in RUN mode and that the configured tag addresses match the actual PLC data block or memory addresses.

    Correct any mismatched tag addresses in the WinCC flexible project, recompile, and re-download to the panel. Check network or bus connections and ensure the PLC communication driver is correctly configured.

    WinCC flexible 2007 crashes or becomes unstable during project editing

    Check the engineering PC for compatibility issues, including operating system version, available RAM, and installed software conflicts. Review the Windows Event Viewer for application error logs related to WinCC flexible.

    Ensure the PC meets the minimum system requirements for WinCC flexible 2007. Apply all available Siemens service packs and patches for the software. Reinstall the application if instability persists after updates.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart