
Siemens 6AV6381-2BJ07-5AH0 WinCC flexible 2007
€ 1.995,00
The Siemens 6AV6381-2BJ07-5AH0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is designed for use with the full range of Siemens operator panels and touch screens.
WinCC flexible 2007 offers a comprehensive engineering environment with tag-based licensing, structured project management, and support for a wide range of Siemens HMI hardware targets including the TP, OP, MP, and Mobile Panel series. The software supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, enabling integration with SIMATIC S7-200, S7-300, S7-400, and other PLC families. It includes features such as alarm management, trend displays, recipe management, user administration, and multi-language project support.
WinCC flexible 2007 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, chemical processing, and building automation. It is particularly suited for machine-level HMI applications where a standardized engineering tool is required to configure operator panels for process visualization, machine control, and data logging. The software's scalability allows it to serve both small standalone machine applications and larger networked production environments.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| License Type | Full software license |
| Compatible HMI Hardware | SIMATIC TP, OP, MP, Mobile Panel series |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 (via legacy support) |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, Ethernet |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Engineering Environment | Tag-based project configuration |
| Alarm Management | Included |
| Recipe Management | Included |
| Multi-language Support | Yes, multiple project languages supported |
| User Administration | Included |
| Trend Display | Included |
| Series/Product Family | SIMATIC WinCC flexible |
Common Error Codes & System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible runtime failed to initialize correctly on the target device.
Check that the correct runtime version is installed on the HMI panel and that the project was compiled without errors before transfer. - Event ID: 2010
- Communication connection lost — the HMI has lost communication with the configured PLC.
Verify network cabling, check PLC address settings, confirm MPI/PROFIBUS/Ethernet parameters match between the HMI project and the PLC configuration. - Event ID: 2020
- Tag read/write error — a configured tag could not be read from or written to the PLC.
Check that the tag address exists in the PLC program, verify data type compatibility, and confirm the PLC is in RUN mode. - Event ID: 3010
- Project transfer error — project download to the HMI panel failed.
Check the transfer cable or network connection, ensure the HMI panel is in transfer mode, and verify that the PC and panel are using compatible WinCC flexible versions. - Event ID: 4000
- License error — no valid license found for WinCC flexible engineering or runtime.
Verify that the license key (dongle or software license) is correctly installed using the Siemens Automation License Manager (ALM). - Event ID: 5010
- Memory overflow — the HMI project exceeds the available memory on the target panel.
Reduce the number of screens, images, or tags in the project, or upgrade to a panel with greater memory capacity. - Event ID: 6001
- Script execution error — a configured VB script within the project encountered a runtime error.
Review the VB script logic in the WinCC flexible engineering environment, check for invalid variable references or syntax errors, and recompile the project.
Frequently Asked Questions
Which Siemens HMI panels are supported by WinCC flexible 2007?
WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific panel firmware version.
Which PLCs can communicate with HMI projects created in WinCC flexible 2007?
WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, WinAC, and several third-party PLCs via OPC or dedicated drivers. MPI, PROFIBUS DP, and Ethernet/PROFINET connections are supported.
What operating systems are compatible with WinCC flexible 2007 engineering software?
WinCC flexible 2007 is compatible with Windows XP Professional and Windows Vista. Windows 7 (32-bit) may be supported with appropriate service packs and patches applied.
Is a hardware dongle required to run WinCC flexible 2007?
WinCC flexible 2007 requires a valid Siemens license managed through the Automation License Manager (ALM). Depending on the license variant, this may be a software-based license or a USB hardware dongle.
Can WinCC flexible 2007 projects be migrated to TIA Portal (WinCC)?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects, though some manual rework may be required depending on the complexity of the original project.
Troubleshooting
Project cannot be transferred to the HMI panel
Check whether the HMI panel is set to transfer mode. Verify the communication interface settings (Ethernet IP address or MPI/PROFIBUS address) match those configured in the WinCC flexible project transfer settings.
Set the panel to transfer mode via the Start Center or loader menu. Ensure the PC and panel are on the same network subnet for Ethernet transfers, or use the correct MPI address and baud rate for serial transfers.
WinCC flexible engineering software fails to start or crashes on launch
Check the Windows Event Viewer for application errors. Verify that the Automation License Manager (ALM) service is running and that a valid license is present.
Reinstall the Automation License Manager and confirm the license is correctly activated. Ensure the PC meets the minimum hardware and OS requirements for WinCC flexible 2007.
HMI panel shows communication error to PLC at runtime
Check the physical connection (cable, switch, or PROFIBUS connector). Verify PLC address, baud rate, and protocol settings in both the WinCC flexible project and the PLC hardware configuration.
Correct any mismatched communication parameters, replace faulty cables or connectors, and ensure the PLC is powered and in RUN mode. Re-download the project after making corrections.
Tags are not updating on the HMI screen during runtime
Check the tag connection settings in the WinCC flexible project. Confirm that the PLC data block or memory address referenced by the tag exists and is accessible.
Verify tag addresses against the current PLC program, ensure the correct data types are assigned, and recompile and re-transfer the project to the panel.
License error displayed when opening WinCC flexible 2007
The Automation License Manager cannot find a valid license for the installed version of WinCC flexible. This may occur after a Windows reinstallation or hardware change.
Open the Automation License Manager, locate the license, and transfer it to the correct drive or reactivate it. If using a USB dongle, ensure it is connected and recognized by Windows.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page



