• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BH07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BH07-5AV0 WinCC flexible 2007

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BH07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BH07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is designed to work in conjunction with Siemens' range of operator panels and visualization systems.

    WinCC flexible 2007 offers a scalable engineering environment supporting the full range of Siemens SIMATIC HMI panels, from Micro Panels to Multi Panels and PC-based runtime systems. The software includes features such as tag management, alarm logging, trend displays, recipe management, and script-based automation. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and integrates directly with STEP 7 for seamless PLC-HMI project coordination. The platform supports multilingual project development and provides a library of pre-built faceplates and objects to accelerate engineering.

    WinCC flexible 2007 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, pharmaceuticals, and energy. It is particularly suited for projects requiring centralized HMI engineering across multiple panel types and PLC families within the Siemens SIMATIC ecosystem. The software enables consistent visualization and operator control across distributed production environments.

    Technical Specifications

    Software Version WinCC flexible 2007
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single-user license
    Compatible HMI Panels SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels
    PLC Integration SIMATIC S7-200, S7-300, S7-400, STEP 7 integration
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet, USB
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Runtime Support WinCC flexible Runtime included
    Language Support Multilingual project development
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE
    Tag Management Supported
    Alarm Logging Supported
    Recipe Management Supported

    Common Error Codes & System Events

    Event ID: 1000000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly.
    Check that the correct Runtime version is installed and that the project file is not corrupted. Reinstall Runtime if necessary.
    Event ID: 1000003
    Communication connection to PLC lost or could not be established.
    Verify network/PROFIBUS/MPI cabling and connection settings. Check PLC address configuration in the HMI project matches the physical setup.
    Event ID: 1000010
    Tag read/write error — a configured tag could not be accessed on the controller.
    Check tag address mapping in the WinCC flexible project. Confirm the PLC data block or memory address exists and is accessible.
    Event ID: 1000020
    License not found or invalid license for WinCC flexible Runtime.
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Transfer or repair the license as required.
    Event ID: 1000030
    Recipe data error — recipe record could not be read from or written to the controller.
    Check recipe configuration and ensure the associated PLC data areas are correctly defined and accessible.
    Event ID: 1000050
    Alarm logging overflow — the alarm buffer has reached its maximum capacity.
    Archive or clear existing alarm logs. Review alarm configuration to reduce unnecessary alarm generation.
    Event ID: 1000060
    Script execution error — a configured VB script encountered a runtime error.
    Review the script in the WinCC flexible engineering environment for syntax or logic errors. Check that all referenced tags and objects exist.

    Frequently Asked Questions

    Which Siemens HMI panels are compatible with WinCC flexible 2007?

    WinCC flexible 2007 supports the full range of SIMATIC HMI panels including Micro Panels (TP 170 Micro, OP 73 Micro), Mobile Panels, Operator Panels (OP 77, TP 177), and Multi Panels (MP 277, MP 377). It also supports PC-based Runtime on compatible Windows operating systems.

    Can WinCC flexible 2007 be integrated with STEP 7?

    Yes, WinCC flexible 2007 integrates directly with SIMATIC STEP 7, allowing shared tag databases and coordinated project engineering between the PLC and HMI environments. This reduces configuration effort and minimizes errors in tag addressing.

    What communication protocols does WinCC flexible 2007 support?

    WinCC flexible 2007 supports PROFIBUS DP, PROFINET, MPI, Ethernet TCP/IP, and USB connections, enabling communication with a wide range of Siemens and third-party controllers.

    Is a separate Runtime license required for WinCC flexible 2007?

    The 6AV6381-2BH07-5AV0 package includes WinCC flexible Runtime. However, the Runtime license is tied to the specific panel or PC on which it is deployed, and additional Runtime licenses may be required for multi-device installations.

    Which Windows operating systems are supported by WinCC flexible 2007?

    WinCC flexible 2007 is compatible with Windows XP (SP2 or higher), Windows Vista, and Windows 7 (32-bit editions). 64-bit operating systems are not natively supported for this version.

    Troubleshooting

    WinCC flexible Runtime fails to start after project download

    Check the Automation License Manager (ALM) to confirm a valid Runtime license is present and not corrupted. Review the Windows Event Viewer for related error entries.

    Transfer a valid WinCC flexible Runtime license using the ALM tool. If the license is corrupted, contact Siemens support for license recovery. Ensure the correct Runtime version matching the project is installed.

    Communication between HMI panel and PLC is not established

    Verify the physical connection (MPI cable, PROFIBUS cable, or Ethernet cable). Check the PLC station address and baud rate settings in the WinCC flexible project match the actual PLC configuration.

    Correct any address or baud rate mismatches in the project connection settings. Replace faulty cables if signal integrity is poor. Ensure the PLC is in RUN mode and accessible on the network.

    Tags show '#####' or invalid values on the HMI screen

    This typically indicates a communication error or an incorrect tag address. Check the tag configuration in the WinCC flexible project and verify the corresponding PLC data block or memory area exists.

    Correct the tag address in the engineering software and re-download the project to the panel. Ensure the PLC program contains the referenced data blocks and that they are not write-protected.

    Project cannot be compiled due to consistency errors in WinCC flexible

    Open the project in WinCC flexible engineering software and run the consistency check (Project > Compile). Review the error list for missing connections, undefined tags, or invalid screen references.

    Resolve each reported error individually — delete or reassign broken tag references, correct screen navigation links, and ensure all communication connections are fully configured before recompiling.

    Alarm messages are not displayed on the HMI panel at runtime

    Check that the alarm view or alarm window object is correctly placed on the relevant screen. Verify that the alarm tags are correctly mapped to PLC bit addresses and that the PLC is actively setting those bits.

    Reconfigure the alarm view object and ensure alarm classes are correctly assigned. Confirm PLC logic is triggering the alarm bits as expected by monitoring the PLC program online.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart