Siemens 6AV6381-2BF07-5AV0 WinCC flexible 2007
€ 1.995,00
The Siemens 6AV6381-2BF07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure, program, and commission Siemens HMI panels, including the OP, TP, MP, and Mobile Panel series. It is a full-featured SCADA and HMI configuration package distributed on physical media with a corresponding license key.
WinCC flexible 2007 supports a wide range of Siemens HMI hardware targets and integrates tightly with the SIMATIC automation environment. The software includes tools for screen design, tag management, alarm logging, recipe management, trend displays, and scripting via VBScript. It supports communication with SIMATIC S7-200, S7-300, S7-400, and other controllers via MPI, PROFIBUS DP, and Ethernet interfaces, and is compatible with Windows XP and Windows Vista operating systems.
This software is used across a broad range of industrial automation applications wherever Siemens HMI panels require engineering and configuration. Typical deployment environments include manufacturing plants, process industries, water treatment facilities, and machine building, where operators need to create and maintain visualization projects for SIMATIC-based control systems. The 2007 edition was widely adopted in machine-level HMI projects requiring reliable panel configuration tools compatible with the SIMATIC hardware portfolio of that era.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| License Type | Full software license |
| Compatible HMI Families | OP, TP, MP, Mobile Panel series (SIMATIC HMI) |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400 |
| Communication Interfaces Supported | MPI, PROFIBUS DP, Industrial Ethernet |
| Scripting Support | VBScript |
| Operating System Compatibility | Windows XP, Windows Vista |
| Series/Product Family | WinCC flexible |
| Alarm Logging | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
| Tag Management | Supported |
Common Error Codes and Software Events
- Compiler Error 1
- Project compilation failed due to invalid or missing tag configuration
Review tag definitions in the project editor, ensure all referenced tags have valid data types and controller addresses assigned, then recompile. - Compiler Error 2
- Screen object references a non-existent tag or variable
Open the affected screen, identify unresolved tag links highlighted by the compiler, reassign or create the missing tags, and recompile the project. - Transfer Error
- Project transfer to HMI panel failed or was interrupted
Verify the communication cable and interface settings match the panel's transfer configuration. Ensure the panel is in transfer mode and retry the download. - License Error
- Software license not found or invalid license key detected
Check that the USB license key (dongle) is properly connected or that the software license is correctly installed via the Automation License Manager. Reactivate if necessary. - Runtime Version Mismatch
- The WinCC flexible Runtime version on the HMI panel does not match the engineering software version
Update the HMI panel's Runtime software to the version compatible with WinCC flexible 2007 using the ProSave tool or via the transfer dialog. - Consistency Check Warning
- Project consistency check detected configuration conflicts or deprecated objects
Run the full consistency check from the project menu, review all warnings listed, correct deprecated object references, and recompile before transferring. - Communication Configuration Error
- No communication connection established between engineering PC and target controller during simulation
Verify the controller connection parameters (IP address, MPI address, or PROFIBUS address) in the project connections editor and ensure the PC adapter or network interface is correctly configured.
Frequently Asked Questions
Which Siemens HMI panels can be configured with WinCC flexible 2007?
WinCC flexible 2007 supports the full range of SIMATIC HMI panels available at the time, including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel 177 series, among others.
Is WinCC flexible 2007 compatible with TIA Portal projects?
No, WinCC flexible 2007 is not compatible with TIA Portal. Projects created in WinCC flexible 2007 must be migrated using the TIA Portal migration tool if a transition to TIA Portal is required.
What operating systems does WinCC flexible 2007 support?
WinCC flexible 2007 is compatible with Windows XP and Windows Vista. It is not officially supported on Windows 7 or later without compatibility workarounds.
Does this license include WinCC flexible Runtime?
The engineering software license (6AV6381-2BF07-5AV0) covers the configuration environment only. WinCC flexible Runtime for PC-based applications is a separate product and requires its own license.
Can WinCC flexible 2007 communicate with S7-1200 or S7-1500 controllers?
WinCC flexible 2007 does not natively support S7-1200 or S7-1500 controllers, as those platforms were introduced with TIA Portal. Communication with these controllers is not supported in this software version.
Troubleshooting
Software fails to install or installation aborts partway through
Check Windows user account permissions and verify that the installation media is not corrupted. Review the installation log file generated in the temp directory for specific error messages.
Run the installer as Administrator, disable antivirus software temporarily during installation, and ensure all prerequisites such as Microsoft .NET Framework and SIMATIC automation components are installed before retrying.
Project transfer to HMI panel fails with a communication error
Verify the physical connection between the PC and the HMI panel using the appropriate cable (PC/PPI, MPI adapter, or Ethernet). Check that the panel is set to transfer mode and that the correct interface is selected in the transfer settings.
Reconfigure the transfer interface in WinCC flexible to match the panel's communication port and address settings. Replace the communication cable if continuity testing reveals a fault, and retry the transfer.
Compiled project generates multiple tag or screen consistency errors
Open the output window after compilation to review the list of errors. Identify screens or tags flagged with unresolved references or data type mismatches.
Correct each flagged tag by reassigning valid controller addresses and data types. Delete and recreate any corrupted screen objects, then perform a full project consistency check before recompiling.
WinCC flexible 2007 does not start or crashes on launch
Check whether the Automation License Manager detects a valid license. Verify that the operating system meets the minimum requirements and that no conflicting software versions are installed.
Reinstall the Automation License Manager and reactivate the license. If the issue persists, perform a repair installation of WinCC flexible 2007 from the original installation media.
Runtime simulation on PC does not connect to the S7 controller
Check the PC adapter configuration in SIMATIC NET or the Set PG/PC Interface dialog. Verify that the correct communication driver is selected and that the controller address matches the project connection settings.
Reconfigure the PG/PC interface to use the correct adapter and protocol (MPI, PROFIBUS, or TCP/IP). Ensure the S7 controller is powered and reachable, then restart the simulation from WinCC flexible.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page