Siemens 6AV6381-2BE08-0AH0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6381-2BE08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC product range.
WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of Siemens HMI hardware, from Micro Panels to Multi Panels and PC-based systems. The software provides tag management, alarm logging, trend displays, recipe management, and report generation. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs. The engineering environment includes a library of pre-built faceplates and supports multi-language project configuration.
WinCC flexible 2008 is widely used in manufacturing automation, process industries, and machine building applications where operator visualization and control are required. It is suitable for configuring HMI projects on production lines, packaging machinery, conveyor systems, and process plants. The software's scalability makes it applicable across small standalone machines as well as larger distributed automation systems.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| Compatible HMI Hardware | SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based HMI |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, Ethernet, RS-422/485 |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| License Type | Single-user license |
| Series/Product Family | SIMATIC WinCC flexible |
| Language Support | Multi-language project configuration |
| Key Functions | Tag management, alarm logging, trend display, recipe management, report generation |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000001
- Communication error between engineering station and HMI panel during project download
Check the communication cable and interface settings. Verify the correct communication driver is selected and that the PG/PC interface is properly configured in the Control Panel. - Event ID: 1000002
- License not found or license key invalid
Verify the software license dongle (USB or disk-based) is properly connected. Use the Automation License Manager to check license status and re-activate if necessary. - Event ID: 1000003
- Project compilation error due to inconsistent tag configuration
Open the project in WinCC flexible and review the tag table for duplicate or incorrectly configured tags. Correct all highlighted errors and recompile the project. - Event ID: 1000004
- Runtime transfer failed — panel memory insufficient
Check available memory on the target HMI panel. Reduce project size by removing unused images, tags, or scripts, then retry the transfer. - Event ID: 1000005
- Connection to PLC lost during runtime
Verify the physical communication link between the HMI panel and PLC. Check IP address or PROFIBUS address settings in the project match the actual PLC configuration. - Event ID: 1000006
- Incompatible runtime version on target panel
Update the HMI panel runtime software to a version compatible with WinCC flexible 2008. Use the ProSave tool to update the panel OS and runtime. - Event ID: 1000007
- Script execution error in project
Review VB scripts within the project for syntax errors or unsupported functions. Check the output window during compilation for specific script error details.
Frequently Asked Questions
Which Siemens PLC families are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as SIMATIC 505 and third-party controllers via OPC or serial drivers.
Which HMI panels can be configured using this software?
The software supports the full range of SIMATIC HMI panels including Micro Panels (KTP series), Mobile Panels, Operator Panels (OP/TP series), Multi Panels, and PC-based HMI systems running WinCC flexible Runtime.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10; users requiring Windows 10 compatibility should consider migrating to TIA Portal with WinCC.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects, though some manual rework may be required depending on the complexity of the project.
What communication protocols does WinCC flexible 2008 support?
The software supports PROFIBUS DP, PROFINET, MPI, Ethernet TCP/IP, RS-422, RS-485, and OPC DA, enabling connectivity to a wide range of Siemens and third-party controllers.
Troubleshooting
Project fails to transfer to the HMI panel
Check the communication interface settings in WinCC flexible under Transfer settings. Verify the cable type (USB, Ethernet, or MPI/PROFIBUS) and confirm the panel is in Transfer mode.
Set the correct interface and transfer channel in the project settings. Ensure the panel is switched to Transfer mode manually or via the Control Panel on the device. Retry the download after confirming the connection.
License error appears when launching WinCC flexible 2008
Open the Automation License Manager (ALM) to check whether a valid license for WinCC flexible 2008 is present and active on the engineering PC.
Insert the license dongle or transfer the license to the local drive using the ALM. If the license is missing, restore it from the original license disk or contact Siemens for license recovery.
Compilation errors occur when building the project
Review the output and error windows in WinCC flexible for specific error messages. Common causes include duplicate tag names, missing connections, or unsupported functions for the target panel type.
Correct all flagged errors in the tag table, screen objects, and scripts. Ensure the selected target panel type in the project properties matches the actual hardware being used.
HMI panel shows 'No connection to PLC' alarm at runtime
Verify the communication parameters configured in WinCC flexible (IP address, PROFIBUS address, or MPI address) match the actual PLC settings. Check the physical cable and network switch if using Ethernet.
Correct any mismatched address settings in the project connections and retransfer the project. Replace or reseat the communication cable and confirm the PLC is powered and running.
WinCC flexible 2008 crashes or freezes during project editing
Check the engineering PC for sufficient RAM and disk space. Verify that the installed version of WinCC flexible 2008 has all available service packs and hotfixes applied.
Install the latest service pack for WinCC flexible 2008 from the Siemens support portal. Increase virtual memory on the PC if RAM is limited, and ensure no conflicting software is running simultaneously.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page