• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BK07-5AH0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BK07-5AH0 WinCC flexible 2007

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BK07-5AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BK07-5AH0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure, program, and commission Siemens HMI panels across the SIMATIC HMI product range. It is designed for use on standard engineering PCs running compatible Windows operating systems.

    WinCC flexible 2007 offers a project-oriented engineering framework with a tag-based communication model, supporting a wide range of Siemens HMI hardware including Micro Panels, Mobile Panels, Operator Panels (OP), Touch Panels (TP), and Multi Panels (MP). The software supports communication via PROFIBUS, MPI, PROFINET/Ethernet, and serial interfaces, enabling integration with SIMATIC S7-200, S7-300, S7-400, and other compatible controllers. It includes features such as faceplates, scripting via VBScript, alarm management, trend displays, recipe management, and multi-language project support.

    WinCC flexible 2007 is used in manufacturing automation, process control, and machine building applications where Siemens SIMATIC HMI panels are deployed. It is suitable for industries including automotive, food and beverage, chemical processing, and general machine manufacturing. The software serves as the central engineering tool for creating operator interfaces that monitor and control industrial processes.

    Technical Specifications

    Software Version WinCC flexible 2007
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single-user license
    Compatible HMI Hardware SIMATIC Micro Panels, OP, TP, MP, Mobile Panels
    Controller Compatibility SIMATIC S7-200, S7-300, S7-400, WinAC
    Communication Interfaces Supported PROFIBUS, MPI, PROFINET, Ethernet, Serial
    Scripting Support VBScript
    Multi-language Support Yes, multi-language project capability
    Operating System Windows XP, Windows 2000 (Professional)
    Series/Product Family WinCC flexible
    Alarm Management Yes
    Recipe Management Yes
    Trend Display Yes

    Common Error Codes & System Events

    Event ID: 1000001
    License not found or invalid license key detected during software startup
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary.
    Event ID: 1000002
    Project compilation error due to inconsistent tag configuration
    Open the project in WinCC flexible, review the output window for specific tag errors, correct tag addressing or data type mismatches, and recompile the project.
    Event ID: 1000003
    Communication error between engineering PC and HMI panel during download
    Check the physical connection (MPI, PROFIBUS, or Ethernet cable). Verify the correct interface and baud rate are configured in the transfer settings. Ensure the HMI panel is in transfer mode.
    Event ID: 1000004
    Incompatible project version detected when opening an existing project
    Use the project migration function within WinCC flexible to convert the project to the current version. Back up the original project before migration.
    Event ID: 1000005
    Runtime simulation failure on engineering PC
    Verify that the WinCC flexible Runtime component is installed. Check that no firewall or antivirus software is blocking the simulation process. Restart the engineering PC if the issue persists.
    Event ID: 1000006
    Insufficient disk space warning during project save or compilation
    Free up disk space on the engineering PC. Move project archives to an external storage location and ensure the installation drive has adequate free space (minimum 2 GB recommended).
    Event ID: 1000007
    Tag limit exceeded for the selected HMI device type
    Review the tag count in the project against the maximum supported by the target HMI hardware. Reduce the number of tags or upgrade to an HMI panel that supports a higher tag count.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports the full range of SIMATIC HMI panels including Micro Panels, Operator Panels (OP), Touch Panels (TP), Multi Panels (MP), and Mobile Panels. Compatibility depends on the specific edition (Micro, Compact, Standard, or Advanced) of the software.

    What controllers can be integrated with WinCC flexible 2007 projects?

    WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, and WinAC controllers via MPI, PROFIBUS, and PROFINET/Ethernet interfaces. Third-party controllers may also be integrated via OPC or serial drivers.

    Is a separate runtime license required to run projects on HMI panels?

    The engineering license (6AV6381-2BK07-5AH0) covers project creation and download. The runtime software is embedded in the HMI panel firmware and does not require a separate runtime license for SIMATIC HMI hardware.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, manual adjustments are typically required after migration due to differences in functionality and hardware support.

    What operating systems are compatible with WinCC flexible 2007?

    WinCC flexible 2007 is compatible with Windows XP Professional and Windows 2000 Professional. It is not natively supported on Windows 7 or later without compatibility configurations, and Siemens recommends using TIA Portal for newer operating systems.

    Troubleshooting

    Software fails to start after installation and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2007 license is present and assigned to the local machine.

    Transfer or reinstall the license using the ALM tool. Ensure the license matches the installed edition (Micro, Compact, Standard, or Advanced). If the license dongle is used, verify it is properly connected.

    Project download to HMI panel fails with a connection timeout error

    Check the physical communication cable between the PC and the HMI panel. Verify the interface type (MPI, PROFIBUS, or Ethernet) and settings in WinCC flexible Transfer dialog match the panel configuration.

    Set the HMI panel to Transfer mode manually. Correct the baud rate and interface settings in the Transfer dialog. Replace the communication cable if a hardware fault is suspected.

    Compiled project generates warnings about unsupported functions for the target device

    Review the output/compilation log in WinCC flexible to identify which functions or objects are flagged as unsupported for the selected HMI device type.

    Replace or remove unsupported objects and functions. Verify that the correct HMI device type and firmware version are selected in the project device settings.

    WinCC flexible 2007 crashes or freezes during project editing on the engineering PC

    Check the engineering PC for adequate RAM and CPU resources. Review Windows Event Viewer for application error logs related to the WinCC flexible process.

    Ensure the PC meets the minimum hardware requirements. Apply all available Siemens service packs and patches for WinCC flexible 2007. Reinstall the software if crashes persist after patching.

    Tags on the HMI panel show incorrect or no values at runtime after download

    Verify the tag addresses in the WinCC flexible project against the actual PLC data block or memory addresses. Check the communication connection status on the HMI panel runtime screen.

    Correct any address mismatches in the tag editor. Ensure the PLC program is running and the communication link between the HMI and PLC is active. Redownload the corrected project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart