• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BH08-0AH0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BH08-0AH0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BH08-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BH08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens operator panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of Siemens HMI hardware targets.

    WinCC flexible 2008 offers a scalable engineering environment supporting project creation for the full range of SIMATIC HMI panels, from Micro Panels up to Multi Panels and PC-based systems. The software includes features such as tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 controller families. The platform provides migration tools for converting projects from earlier ProTool and WinCC flexible versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, and machine building industries where Siemens SIMATIC HMI panels are deployed. It is suitable for applications in automotive production lines, food and beverage processing, packaging machinery, and water treatment facilities. The software's scalability makes it applicable to both small standalone machine HMIs and larger distributed visualization systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    Compatible HMI Hardware SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels, Panel PCs
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet, USB
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7
    License Type Single-user software license
    Series/Product Family SIMATIC WinCC flexible
    Migration Support ProTool and WinCC flexible earlier versions
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
    Check that the correct runtime version is installed on the HMI panel and that the project was compiled without errors in the engineering software.
    Event ID: 1000003
    Communication connection to the PLC could not be established.
    Verify the communication settings (IP address, MPI address, or PROFIBUS address) in the project match the PLC configuration. Check physical cabling and interface settings.
    Event ID: 1000010
    Tag read/write error — a configured tag could not be accessed on the controller.
    Confirm the tag address exists in the PLC program and that the data type in the HMI project matches the PLC variable type.
    Event ID: 1000020
    License not found — no valid WinCC flexible license detected on the engineering PC.
    Install or transfer a valid software license using the Siemens Automation License Manager (ALM). Ensure the license matches the installed software version.
    Event ID: 1000030
    Project transfer error — download of the project to the HMI panel failed.
    Check the transfer cable or network connection between the engineering PC and the HMI panel. Ensure the panel is in transfer mode and the correct transfer channel is selected.
    Event ID: 1000040
    Compilation error — the project could not be compiled due to configuration inconsistencies.
    Review the error list in the WinCC flexible compiler output. Correct invalid tag references, missing screen objects, or unsupported functions for the target HMI device.
    Event ID: 1000050
    Alarm buffer overflow — the alarm log has exceeded its configured capacity.
    Increase the alarm buffer size in the project settings or implement alarm archiving to an external storage medium. Clear the alarm buffer on the HMI device.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (TP 170 Micro, OP 73 Micro), Mobile Panels, Operator Panels (OP 77, TP 177, OP 177), Multi Panels, and Panel PCs. The specific feature set available depends on the target panel selected during project creation.

    Is WinCC flexible 2008 compatible with SIMATIC S7-1200 controllers?

    Yes, WinCC flexible 2008 with the appropriate service pack supports communication with SIMATIC S7-1200 controllers via Ethernet/PROFINET. Tag addressing follows the standard S7 communication conventions.

    Can existing ProTool projects be migrated to WinCC flexible 2008?

    Yes, WinCC flexible 2008 includes a migration wizard that converts ProTool projects and earlier WinCC flexible project versions. Some manual adjustments may be required after migration due to differences in functionality between software generations.

    What operating systems are supported for running the WinCC flexible 2008 engineering software?

    WinCC flexible 2008 is supported on Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not natively supported on Windows 10 or Windows 11 without compatibility measures.

    What is the Automation License Manager (ALM) and is it required?

    The Siemens Automation License Manager is a license management tool required to install, transfer, and manage WinCC flexible software licenses. It must be installed on the engineering PC before activating the WinCC flexible 2008 license.

    Troubleshooting

    WinCC flexible 2008 will not install or reports a license error after installation

    Check whether the Automation License Manager (ALM) is installed and detects a valid license. Open ALM and verify the license status for WinCC flexible 2008.

    Install the Automation License Manager if not present, then transfer or activate the license supplied with the 6AV6381-2BH08-0AH0 package. Ensure the license matches the exact software version installed.

    Project cannot be transferred to the HMI panel

    Verify the transfer channel settings in WinCC flexible match the physical connection (USB, Ethernet, or MPI/PROFIBUS). Confirm the HMI panel is set to transfer mode via its Control Panel or Start Center.

    Correct the transfer channel configuration in the project transfer dialog. Restart the HMI panel in transfer mode and retry the download. Check and replace the transfer cable if a physical connection fault is suspected.

    HMI panel shows 'No connection to PLC' at runtime

    Check the communication parameters configured in the WinCC flexible project (PLC IP address, MPI node address, or PROFIBUS address) against the actual PLC settings. Inspect the physical network or bus cable for faults.

    Correct the communication parameters in the WinCC flexible project and retransfer to the panel. Replace or reseat the communication cable. Verify the PLC is powered and its communication interface is active.

    Compilation fails with errors referencing unsupported functions

    Review the compiler error list to identify which functions or objects are flagged. Compare the functions used in the project against the feature set supported by the selected target HMI device.

    Replace unsupported functions with alternatives compatible with the target panel, or change the target device to one that supports the required features. Recompile the project after making corrections.

    WinCC flexible 2008 engineering software crashes or becomes unstable on the PC

    Check the PC operating system version and installed service packs for compatibility. Review the Windows Event Viewer for application error logs related to the WinCC flexible process.

    Ensure the PC meets the minimum system requirements and runs a supported OS (Windows XP SP2, Vista, or Windows 7). Install all recommended Siemens service packs and patches for WinCC flexible 2008. Repair or reinstall the software if instability persists.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart