Siemens 6AV6381-2BH08-0AV0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6381-2BH08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC product range.
WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based runtime systems. The software includes features such as tag management, alarm logging, trend displays, recipe management, and multi-language project support. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 controller families. The 2008 version introduced enhanced usability features, improved library management, and expanded device support compared to earlier releases.
WinCC flexible 2008 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, pharmaceuticals, and packaging. It is particularly suited for projects requiring centralized HMI engineering across multiple panel types within a single software environment. The software enables engineers to configure, simulate, and commission operator interfaces without requiring separate tools for different panel variants.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Product Family | SIMATIC WinCC flexible |
| License Type | Engineering Software License |
| Compatible HMI Devices | SIMATIC Micro Panels, OP/TP series, Multi Panels, PC-based HMI |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, Ethernet |
| Operating System | Windows XP, Windows Vista, Windows 7 (32/64-bit) |
| Project Simulation | Integrated software simulation (without hardware) |
| Language Support | Multi-language project configuration |
| Alarm Management | Integrated alarm logging and display |
| Recipe Management | Supported |
| Trend Display | Supported |
| Certifications | CE |
Common Error Codes and System Events
- Error 1920
- Storage device not accessible during project transfer or runtime startup
Verify the target storage path is accessible and that the correct drive or memory card is connected and formatted properly - Error 2562
- License not found or license key missing for WinCC flexible runtime or engineering
Check that the software license (dongle or software key) is correctly installed; use the Automation License Manager to verify license status - Communication Error
- No connection established between engineering PC and HMI panel during project download
Verify network or MPI/PROFIBUS cable connections, check IP address or bus address settings, and confirm the correct communication driver is selected in the project - Compilation Error
- Project compilation fails due to inconsistent tag references or unsupported device configuration
Review the output log for specific tag or screen references, correct invalid tag connections, and ensure the selected target device matches the physical panel - Transfer Error
- Project transfer to HMI panel aborted or fails to complete
Check that the panel is in transfer mode, verify the communication interface settings match on both PC and panel, and ensure sufficient free memory on the target device - Runtime Startup Error
- WinCC flexible Runtime fails to start on PC-based system
Confirm that the correct runtime license is installed via Automation License Manager, check Windows user permissions, and verify that no conflicting software versions are installed - Device Mismatch Warning
- Configured HMI device type in project does not match the connected physical device
Open the project in the engineering software, navigate to device settings, and update the target device type to match the actual hardware before retransferring
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports a wide range of SIMATIC HMI devices including Micro Panels (KTP series), Operator Panels (OP 77, OP 170), Touch Panels (TP 177, TP 270), Multi Panels (MP 277, MP 377), and PC-based runtime systems. The specific edition of the software (Micro, Compact, Standard, or Advanced) determines the range of supported devices.
What editions of WinCC flexible 2008 are available?
WinCC flexible 2008 is available in four editions: Micro, Compact, Standard, and Advanced. Each edition supports a progressively larger range of HMI devices and project complexity, with the Advanced edition supporting the full device portfolio including Multi Panels and PC runtime.
Is WinCC flexible 2008 compatible with TIA Portal projects?
WinCC flexible 2008 is not natively compatible with TIA Portal (which uses WinCC in the TIA engineering framework). However, Siemens provides a migration tool to convert WinCC flexible projects for use within TIA Portal when upgrading to newer platforms.
What operating systems are supported for installing WinCC flexible 2008?
WinCC flexible 2008 supports installation on Windows XP (SP2 or later), Windows Vista, and Windows 7 in both 32-bit and 64-bit variants. It is not officially supported on Windows 8, Windows 10, or later operating systems.
Can WinCC flexible 2008 simulate projects without a physical HMI panel?
Yes, WinCC flexible 2008 includes an integrated simulation function that allows engineers to test and validate HMI projects on the engineering PC without requiring a physical panel, which is useful for offline commissioning and testing.
Troubleshooting
Automation License Manager does not detect the WinCC flexible 2008 license
Open the Automation License Manager and check whether the license key appears under the installed licenses list. Verify whether a hardware dongle is required or if a software-based license was purchased.
Ensure the USB license dongle is connected if applicable, or re-run the license installation using the original license media. If the license was transferred, use the Automation License Manager transfer function to restore it to the current machine.
Project compilation fails with tag limit exceeded error
Check the total number of configured tags in the project against the maximum tag count permitted by the installed WinCC flexible edition (Micro, Compact, Standard, or Advanced).
Reduce the number of tags in the project, remove unused tags, or upgrade to a higher edition of WinCC flexible 2008 that supports a larger tag count.
Project transfer to HMI panel fails repeatedly
Verify the communication settings in the project transfer dialog, including the interface type (Ethernet, USB, MPI), IP address or bus address, and that the panel is set to transfer mode (accessible via the panel's Start Center or Control Panel).
Correct any mismatched communication parameters, ensure the panel is in transfer mode, and check that no firewall or antivirus software is blocking the transfer process on the engineering PC.
WinCC flexible 2008 crashes or freezes during project editing on Windows 7
Check Windows Event Viewer for application error logs referencing WinCC flexible processes. Verify that all required service packs and patches for both Windows 7 and WinCC flexible 2008 are installed.
Install the latest WinCC flexible 2008 service pack (SP5 or later), ensure the PC meets the minimum hardware requirements, and disable any unnecessary background applications that may conflict with the software.
Imported project from an older WinCC flexible version displays device compatibility warnings
When opening a project created in an earlier version of WinCC flexible, the software may flag device type or tag incompatibilities due to changes in device support between versions.
Use the built-in project upgrade wizard to migrate the project to WinCC flexible 2008 format, review all flagged warnings in the output log, and manually correct any device-specific settings that could not be automatically converted.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page