• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0HH0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-2DF07-0HH0 SIMATIC WinCC

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0HH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0HH0 is a WinCC (Windows Control Center) SCADA/HMI software package belonging to Siemens' SIMATIC automation software family. This part number corresponds to a WinCC runtime or configuration license, designed to provide supervisory control and data acquisition capabilities for industrial process visualization on standard PC-based hardware. It is part of Siemens' broader SIMATIC HMI software portfolio, which integrates tightly with SIMATIC S7 PLCs and the TIA Portal engineering framework.

    The 6AV6372-2DF07-0HH0 license provides process visualization, alarm management, trending, and reporting functionality within the WinCC environment. It supports communication via PROFIBUS, PROFINET, MPI, and OPC/OPC UA interfaces, enabling connectivity to a wide range of Siemens and third-party controllers. The software includes tag-based licensing, historical data archiving, and a scripting environment based on ANSI C and VBScript for custom automation logic and screen control.

    WinCC is widely deployed in industries such as automotive manufacturing, chemical processing, water and wastewater treatment, power generation, and building automation. Its PC-based architecture allows integration with enterprise-level IT systems, MES, and ERP platforms, making it suitable for applications requiring both plant-floor control and higher-level data management. The scalable licensing model allows it to be used in standalone single-station configurations as well as multi-client/server architectures for large distributed installations.

    Technical Specifications

    Software Family SIMATIC WinCC
    Software Type SCADA / HMI Visualization Software
    Platform PC-based (Windows OS)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC, OPC UA
    Scripting Support ANSI C, VBScript
    Alarm Management Included
    Historical Data Archiving Included
    Trending / Reporting Included
    License Type Runtime / Configuration License
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Engineering Integration TIA Portal compatible
    Series / Product Family SIMATIC WinCC

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure — the runtime could not be initialized due to a configuration or licensing error.
    Verify that the WinCC license is correctly installed and activated. Check the Windows Event Viewer and WinCC diagnostic log for detailed error messages.
    Event ID: 1001
    Communication channel to PLC lost — the configured communication driver cannot establish or maintain a connection to the target controller.
    Check network cabling and PROFIBUS/PROFINET connections. Verify PLC address settings in the WinCC tag management and confirm the PLC is in RUN mode.
    Event ID: 2501
    Tag archiving error — the archive database cannot write process values due to a disk space or database integrity issue.
    Check available disk space on the archive drive. Run the WinCC database consistency check tool and clear old archive data if necessary.
    Event ID: 112
    License not found or license count exceeded — the number of configured tags or clients exceeds the licensed quantity.
    Verify the installed license using the Siemens Automation License Manager (ALM). Upgrade the license to the required tag count or client count.
    Event ID: 10000
    OPC server connection failure — WinCC OPC client cannot connect to the specified OPC server.
    Confirm the OPC server is running and accessible on the network. Check DCOM security settings and firewall rules on both the WinCC station and the OPC server host.
    Event ID: 3001
    Redundancy switchover event — WinCC has detected a failure on the primary server and switched to the redundant server.
    Investigate the cause of the primary server failure (hardware, OS, or network). Restore the primary server and perform a manual synchronization to re-establish redundancy.
    Event ID: 6001
    Script runtime error — a configured ANSI C or VBScript action has encountered an execution error.
    Open the WinCC Script Debugger and review the error log for the affected script. Correct syntax or logic errors in the script editor and re-activate the runtime.

    Frequently Asked Questions

    What type of license does the 6AV6372-2DF07-0HH0 provide?

    This part number corresponds to a WinCC software license within the SIMATIC WinCC product family. The specific license tier (e.g., Runtime 128 tags, 2048 tags, or full configuration) should be confirmed against the Siemens order documentation for this exact part number.

    Which Siemens PLCs are compatible with this WinCC software?

    WinCC is compatible with the full range of SIMATIC S7 controllers including S7-300, S7-400, S7-1200, and S7-1500 series PLCs, communicating via MPI, PROFIBUS, or PROFINET depending on the controller type.

    Can WinCC communicate with third-party PLCs or controllers?

    Yes, WinCC supports OPC and OPC UA communication standards, allowing connectivity to third-party PLCs and automation systems that provide an OPC server interface.

    Is this software compatible with the TIA Portal engineering environment?

    WinCC integrates with the Siemens TIA Portal, allowing unified engineering of PLC and HMI projects. Depending on the WinCC version, it may be used as a standalone application or within the TIA Portal framework.

    What operating system is required to run WinCC?

    WinCC requires a Windows-based PC operating system; supported versions depend on the WinCC release version. Siemens typically supports Windows 10 (64-bit) and Windows Server editions for current WinCC releases.

    Troubleshooting

    WinCC Runtime fails to start after installation

    Check the Siemens Automation License Manager (ALM) to confirm the license is present and valid. Review the Windows Event Viewer Application log and the WinCC diagnostic files located in the WinCC installation directory for specific error messages.

    Reinstall or transfer the correct WinCC license using the ALM tool. Ensure the PC meets the minimum hardware and OS requirements for the installed WinCC version and that all required Microsoft components (SQL Server, .NET Framework) are correctly installed.

    No communication between WinCC and the SIMATIC S7 PLC

    Verify the network connection physically and check the IP address or PROFIBUS address configured in the WinCC channel settings matches the PLC configuration. Use Siemens communication diagnostic tools (e.g., STEP 7 or TIA Portal online diagnostics) to confirm the PLC is reachable.

    Correct the communication channel settings in WinCC Tag Management. Ensure the correct communication driver is installed and activated. Check firewall and antivirus software that may be blocking the communication port.

    Process values are not updating on WinCC screens

    Check whether the affected tags show a quality status of 'Bad' or 'Uncertain' in the WinCC Tag Management or runtime diagnostics. Determine if the issue is isolated to specific tags or affects all tags on a communication channel.

    Restart the affected communication channel in WinCC Channel Diagnostics. Verify tag addresses match the actual PLC data block or memory addresses. If the issue persists, restart the WinCC Runtime and check for database or driver errors in the diagnostic log.

    WinCC archive database grows excessively large and causes disk space warnings

    Review the configured archive cycle times and retention periods in WinCC Archive Manager. Identify which process value or alarm archives are consuming the most space using the WinCC database tools.

    Reduce archive cycle times or shorten the data retention period for non-critical tags. Use the WinCC backup and segmentation functions to offload older archive data. Schedule regular archive maintenance tasks to prevent uncontrolled database growth.

    WinCC displays a license warning or enters demonstration mode unexpectedly

    Open the Siemens Automation License Manager (ALM) and check the status of the installed WinCC license. Confirm the license has not expired and that the licensed tag count has not been exceeded by the current project configuration.

    Transfer a valid license to the WinCC station using the ALM tool. If the tag count is exceeded, reduce the number of configured tags or upgrade to a higher-tier license. Ensure the license dongle (if applicable) is securely connected to the PC.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart