• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0GX0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6372-2DF07-0GX0 WinCC flexible 2007

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0GX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0GX0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of operator panels.

    WinCC flexible 2007 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a library of pre-built faceplates and symbols, and supports multi-language project configuration for international deployments. The software is compatible with Windows XP and Windows Vista operating systems as per its release generation.

    WinCC flexible 2007 is widely used in manufacturing, process automation, and machine building industries where SIMATIC HMI panels such as the TP, OP, MP, and Mobile Panel series are deployed. It is particularly suited for applications requiring structured visualization of machine states, process data logging, and operator interaction. The software enables engineers to configure projects offline and download them directly to compatible Siemens HMI hardware targets.

    Technical Specifications

    Software Version WinCC flexible 2007
    Series/Product Family SIMATIC WinCC flexible
    License Type Single-user engineering license
    Compatible PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Compatible HMI Panels SIMATIC TP, OP, MP, Mobile Panel series
    Operating System Windows XP, Windows Vista
    Project Languages Multi-language support
    Certifications CE
    Software Type Engineering and Runtime configuration software
    Alarm Logging Supported
    Recipe Management Supported
    Trend Display Supported
    Script Support VB Script-based automation

    Common Error Codes and System Events

    Event ID: 1000
    Project compilation error — one or more tags or screens contain invalid configurations preventing successful project build.
    Open the validation log in the WinCC flexible editor, identify the flagged objects, and correct tag addresses or screen references before recompiling.
    Event ID: 1010
    Communication connection to PLC failed — the HMI runtime cannot establish a connection to the configured SIMATIC controller.
    Verify PLC address settings, check MPI or PROFIBUS cable connections, confirm the PLC is in RUN mode, and ensure the correct communication driver is selected in the project.
    Event ID: 1020
    Tag limit exceeded — the number of configured tags in the project exceeds the licensed tag count for the installed runtime version.
    Reduce the number of configured tags or upgrade the WinCC flexible runtime license to a higher tag class.
    Event ID: 1030
    License not found — the software cannot detect a valid license for WinCC flexible engineering or runtime on the host system.
    Insert the valid license key or USB dongle, or use the Automation License Manager to transfer the license to the engineering PC.
    Event ID: 1040
    Project transfer failed — download of the project to the target HMI panel was interrupted or unsuccessful.
    Check the transfer cable or Ethernet connection, ensure the HMI panel is in transfer mode, and verify that the target panel type matches the project configuration.
    Event ID: 1050
    Runtime startup error — WinCC flexible runtime failed to initialize on the target panel or PC.
    Check available memory on the target device, verify the runtime version is compatible with the project version, and restart the device after clearing temporary runtime files.
    Event ID: 1060
    Alarm server error — the alarm logging system failed to record or display alarms due to a configuration or storage issue.
    Check the alarm log storage path, verify sufficient disk or flash memory is available, and review alarm group configuration in the project editor.

    Frequently Asked Questions

    Which SIMATIC HMI panels are compatible with WinCC flexible 2007?

    WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific panel firmware version and the project configuration.

    Which PLC families can communicate with projects created in WinCC flexible 2007?

    WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs using MPI, PROFIBUS DP, and Industrial Ethernet protocols. Third-party PLC communication is also possible via OPC.

    What operating systems are supported by WinCC flexible 2007?

    WinCC flexible 2007 is designed for use on Windows XP and Windows Vista. It is not natively supported on Windows 7 or later without compatibility workarounds.

    Does WinCC flexible 2007 support multi-language project configuration?

    Yes, WinCC flexible 2007 includes multi-language support, allowing engineers to configure HMI projects in multiple languages and switch between them at runtime on the operator panel.

    Is a hardware dongle or software license key required to run WinCC flexible 2007?

    Yes, a valid license managed through the Siemens Automation License Manager (ALM) is required. The license can be stored on a USB dongle or transferred to the engineering PC's hard drive.

    Troubleshooting

    WinCC flexible 2007 software fails to start after installation

    Check the Automation License Manager to confirm a valid license is present and active. Verify that the operating system version is compatible (Windows XP or Vista).

    Transfer or activate the correct license using the Automation License Manager. If the OS is incompatible, install the software on a supported Windows XP or Vista environment or use a virtual machine.

    Project cannot be compiled due to multiple validation errors

    Open the output window in the WinCC flexible editor and review the error list. Common causes include invalid PLC tag addresses, missing screen references, or unsupported object properties for the selected target panel.

    Correct each flagged error in the project editor, ensuring all tag addresses match the PLC data block structure and all screen navigation references point to existing screens. Recompile after each correction.

    Project transfer to HMI panel fails repeatedly

    Verify the transfer connection type (USB, Ethernet, or MPI) and confirm the panel is set to transfer mode. Check that the target panel model selected in the project matches the physical hardware.

    Switch the HMI panel to transfer mode manually via the panel's start center, confirm the correct IP address or COM port is configured in the transfer settings, and retry the download.

    Runtime alarms are not displayed on the HMI panel after project download

    Check the alarm configuration in the project, including alarm classes, trigger tags, and display settings. Verify that the alarm view object is correctly placed on the relevant screen.

    Review and correct the alarm class assignments and tag trigger conditions in the WinCC flexible editor. Ensure the alarm view control is added to the appropriate screen and that the runtime alarm server is enabled in the project settings.

    Communication between HMI panel and S7 PLC drops intermittently

    Check the physical MPI or PROFIBUS cable for damage or loose connectors. Verify the bus termination resistors are correctly placed at both ends of the network. Review the configured communication timeout values in the project.

    Replace damaged cables, ensure proper bus termination, and increase the communication timeout values in the WinCC flexible connection settings. For Ethernet connections, check network switch configuration and IP address conflicts.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart