• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0FH0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-2DF07-0FH0 SIMATIC WinCC

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0FH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0FH0 is a WinCC (Windows Control Center) runtime software license belonging to Siemens' SIMATIC HMI software family. WinCC is a PC-based SCADA and HMI visualization platform designed for process monitoring, data acquisition, and operator control in industrial automation environments. This specific part number corresponds to a WinCC runtime package with a defined power tag count, enabling process visualization on standard PC hardware running Windows operating systems.

    The WinCC runtime software provides a comprehensive set of features including tag-based process data management, alarm and event logging, trend displays, and historical data archiving. It supports a wide range of communication drivers for connecting to Siemens SIMATIC S7 PLCs via PROFIBUS, PROFINET, and MPI, as well as OPC DA/UA interfaces for third-party system integration. The platform includes a scripting environment based on VBScript and ANSI C for custom automation logic, and supports redundant server configurations for high-availability applications.

    WinCC runtime software is widely deployed in process industries such as chemical, pharmaceutical, water treatment, and energy management, as well as in discrete manufacturing environments including automotive assembly and machine tool operations. Its scalable architecture allows deployment from single-station HMI setups to distributed multi-client/server SCADA systems covering entire plant floors. The software's compatibility with the broader Siemens TIA Portal and SIMATIC ecosystem makes it a common choice in facilities already operating Siemens PLC and drive infrastructure.

    Technical Specifications

    Software Type WinCC Runtime Software
    Product Family SIMATIC WinCC
    Operating System Compatibility Windows 10 / Windows Server 2016 or later (64-bit)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Scripting Support VBScript, ANSI C
    Archiving Alarm logging, process value archiving, report generation
    Redundancy Support Yes, server redundancy supported
    License Type Runtime license (single installation)
    Series SIMATIC WinCC V7
    Certifications CE, UL
    Integration TIA Portal compatible, SIMATIC IT compatible

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC runtime startup failure — the runtime could not initialize correctly, often due to a missing or invalid license.
    Verify that the WinCC license is correctly installed using the Siemens Automation License Manager. Reinstall the license if necessary.
    Event ID: 1001
    Communication error to PLC — the configured communication channel to the SIMATIC controller cannot be established.
    Check network cable connections, verify IP address or MPI/PROFIBUS address settings in the channel configuration, and confirm the PLC is powered and running.
    Event ID: 112
    Tag logging runtime error — process value archiving has encountered an error and data may not be recorded.
    Check the archive database configuration, verify sufficient disk space, and restart the WinCC Tag Logging service via the SIMATIC WinCC Service Manager.
    Event ID: 10241
    Alarm logging error — the alarm server has encountered a fault and alarm events may not be recorded or displayed correctly.
    Restart the WinCC Alarm Logging runtime component via the Service Manager and verify the alarm database is accessible and not corrupted.
    License Error
    No valid WinCC runtime license found or the power tag limit has been exceeded.
    Open the Siemens Automation License Manager, verify the correct license is present and active, and ensure the number of configured power tags does not exceed the licensed limit.
    Communication Driver Error
    A configured communication driver has failed to load or has stopped responding during runtime.
    Check the channel diagnostics in WinCC Explorer, verify driver installation, and restart the affected communication channel. Reinstall the driver if the issue persists.
    Database Connection Error
    WinCC cannot connect to the underlying Microsoft SQL Server database used for archiving and configuration storage.
    Verify that the SQL Server instance (typically WINCC) is running via Windows Services, check SQL Server error logs, and ensure no disk space or permission issues are present.

    Frequently Asked Questions

    What is the power tag limit for the 6AV6372-2DF07-0FH0 WinCC runtime license?

    The 6AV6372-2DF07-0FH0 corresponds to a WinCC runtime license with a specific power tag count defined by the part number suffix. Refer to the Siemens SIMATIC WinCC ordering data documentation to confirm the exact tag count for this variant, as tag limits range from 128 to 150,000 depending on the license tier.

    Which PLCs are compatible with this WinCC runtime software?

    WinCC runtime is compatible with the full range of SIMATIC controllers including S7-300, S7-400, S7-1200, and S7-1500 series PLCs via PROFIBUS, PROFINET, and MPI. Third-party PLCs can also be connected using OPC DA or OPC UA interfaces.

    Can this WinCC runtime license be used in a redundant server configuration?

    Yes, WinCC supports redundant server configurations where a standby server automatically takes over if the primary server fails. A separate redundancy license is required in addition to the standard runtime license.

    Is this software compatible with the Siemens TIA Portal?

    WinCC V7 runtime operates as a standalone SCADA platform and is not directly configured within TIA Portal; TIA Portal is used for WinCC Comfort/Advanced panel configuration. However, WinCC V7 integrates with the broader SIMATIC ecosystem and can communicate with TIA Portal-configured PLCs.

    What database system does WinCC use for archiving?

    WinCC uses Microsoft SQL Server as its underlying database engine for storing alarm logs, process value archives, and configuration data. The SQL Server instance is installed automatically during WinCC installation.

    Troubleshooting

    WinCC runtime fails to start and displays a license error

    Open the Siemens Automation License Manager and check whether a valid WinCC runtime license is present and assigned to the local computer. Verify the license has not expired or been transferred to another machine.

    Transfer or reinstall the correct WinCC runtime license using the Automation License Manager. Ensure the license matches the installed WinCC version and the required power tag count.

    No process data is displayed on WinCC screens; all tags show error status

    Check the WinCC channel diagnostics in WinCC Explorer under the communication driver. Verify the PLC is reachable via ping (for PROFINET/Ethernet) or check MPI/PROFIBUS cable connections and address settings.

    Correct the IP address, subnet, or bus address configuration in the WinCC channel settings. Restore network connectivity to the PLC and restart the communication driver from the WinCC Service Manager.

    Historical trend data or alarm logs are missing or not being recorded

    Check whether the SQL Server WINCC instance is running via Windows Services Manager. Verify available disk space on the archive drive and review the WinCC Tag Logging and Alarm Logging runtime status in the Service Manager.

    Free up disk space if necessary, restart the SQL Server instance and the WinCC archiving services. If the database is corrupted, restore from a backup or reconfigure the archive settings in WinCC Explorer.

    WinCC runtime crashes or freezes intermittently during operation

    Review the Windows Event Viewer and the WinCC diagnostic log files located in the WinCC installation directory for error entries. Check system resource usage (CPU, RAM, disk I/O) to identify resource exhaustion.

    Ensure the PC meets the minimum hardware requirements for the installed WinCC version and tag count. Close unnecessary background applications, apply the latest WinCC service pack and Windows updates, and consider upgrading RAM or storage if resource limits are being reached.

    OPC client cannot connect to WinCC OPC server

    Verify that the WinCC OPC server service is running and that Windows DCOM settings allow remote OPC connections. Check firewall rules on both the WinCC server and the OPC client machine.

    Configure DCOM permissions using dcomcnfg to allow the OPC client user account access. Open the required firewall ports for OPC DA (typically port 135 and dynamic RPC ports) or switch to OPC UA which uses a fixed configurable port for simpler firewall management.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart