Siemens 6AV6372-2DF07-0EX0 SIMATIC WinCC
€ 1.995,00
The Siemens 6AV6372-2DF07-0EX0 is a WinCC (Windows Control Center) software package from Siemens' SIMATIC HMI product family. WinCC is a supervisory control and data acquisition (SCADA) and human-machine interface (HMI) software platform designed for process visualization and control in industrial automation environments. This specific part number corresponds to a WinCC runtime or configuration license within the SIMATIC WinCC V7 series.
The WinCC software provides a comprehensive set of features including process visualization, alarm management, trend display, reporting, and historical data archiving. It supports a wide range of communication interfaces and drivers, enabling connectivity to SIMATIC S7 PLCs via PROFIBUS and Industrial Ethernet, as well as third-party controllers via OPC DA/UA. The platform supports redundant server configurations, multi-client architectures, and web-based client access, making it suitable for both standalone and distributed SCADA installations. WinCC integrates with the SIMATIC PCS 7 process control system and supports scripting via VBScript and ANSI-C for custom automation logic.
WinCC is widely deployed in industries such as automotive manufacturing, chemical processing, water and wastewater treatment, food and beverage production, and energy management. Its scalable architecture allows it to serve applications ranging from single-station HMI panels to large-scale distributed control systems with multiple servers and hundreds of clients. The software's robust data logging, reporting, and alarm handling capabilities make it particularly suitable for regulated industries requiring comprehensive process documentation and audit trails.
Technical Specifications
| Software Platform | Microsoft Windows (32/64-bit) |
|---|---|
| Product Family | SIMATIC WinCC V7 |
| Software Type | SCADA / HMI Visualization Software |
| Communication Interfaces | PROFIBUS, Industrial Ethernet, OPC DA, OPC UA |
| PLC Compatibility | SIMATIC S7-300, S7-400, S7-1200, S7-1500, third-party via OPC |
| Architecture Support | Single-station, Client/Server, Redundant Server |
| Scripting Languages | VBScript, ANSI-C |
| Web Access | Supported via WinCC Web Navigator |
| Certifications | CE |
| Integration | SIMATIC PCS 7 compatible |
Common Error Codes & System Events
- Event ID: 1000000
- WinCC runtime startup error — the runtime system failed to initialize correctly.
Check Windows Event Viewer for detailed error messages. Verify that all required WinCC services are running and that the license is valid and properly installed. - Event ID: 1000001
- License not found or invalid — WinCC cannot find a valid runtime license.
Verify that the SIMATIC license (via Automation License Manager) is correctly installed and not expired. Transfer or repair the license using the Automation License Manager tool. - Event ID: 112
- Database connection error — WinCC cannot connect to the SQL Server database used for archiving.
Check that Microsoft SQL Server is running. Verify SQL Server instance name and credentials in the WinCC project settings. Restart SQL Server service if necessary. - Event ID: 1000003
- Communication driver error — a configured channel driver has failed to load or connect to the target PLC.
Check the channel configuration in WinCC Explorer. Verify network connectivity to the PLC, confirm correct IP address or PROFIBUS address, and ensure the appropriate communication driver is installed. - Event ID: 1000010
- Archive backup failure — the cyclic archive backup process could not complete.
Check available disk space on the archive target drive. Verify backup path permissions and ensure the WinCC archive service is running without errors. - Event ID: 1000020
- Tag logging overflow — the tag logging buffer has exceeded its capacity.
Reduce the number of logged tags or increase the logging cycle time. Check disk performance and ensure the SQL Server archive database is not full. - Event ID: 1000030
- Alarm logging error — alarm events could not be written to the alarm archive.
Check SQL Server status and available disk space. Verify alarm logging configuration in WinCC and restart the alarm logging runtime if necessary.
Frequently Asked Questions
What type of license does the 6AV6372-2DF07-0EX0 provide?
The 6AV6372-2DF07-0EX0 is a WinCC software license within the SIMATIC WinCC V7 family. The specific license type (e.g., runtime with a defined number of power tags or a full configuration license) should be confirmed against the Siemens product catalog, as the suffix codes define the exact scope.
Which operating systems are supported by this WinCC version?
SIMATIC WinCC V7 supports Microsoft Windows 7 (64-bit), Windows 10 (64-bit), and Windows Server 2012/2016 R2 depending on the specific service pack version. It is not compatible with 32-bit operating systems in later releases.
Can WinCC communicate with non-Siemens PLCs?
Yes, WinCC supports OPC DA and OPC UA interfaces, allowing communication with third-party PLCs and automation systems that provide OPC-compatible servers. Dedicated channel drivers for some third-party systems may also be available.
Does WinCC support redundant server configurations?
Yes, WinCC supports a redundant server architecture where two WinCC servers operate in parallel. In the event of a primary server failure, clients automatically switch to the standby server, ensuring continuous process visualization.
How is the WinCC license managed?
WinCC licenses are managed using the Siemens Automation License Manager (ALM) software. Licenses can be stored on a USB dongle or on the hard drive of the engineering or runtime PC, and can be transferred between systems using the ALM tool.
Troubleshooting
WinCC Runtime fails to start after project is opened
Check the Windows Event Viewer under Application and System logs for WinCC-related errors. Verify that all WinCC services (Tag Logging, Alarm Logging, etc.) are running in Windows Services. Confirm that the SQL Server instance required by WinCC is active.
Restart the SQL Server service and all WinCC-related Windows services. If a license error is reported, use the Automation License Manager to verify and repair the license. Reinstall WinCC runtime components if service entries are missing.
No communication between WinCC and the SIMATIC S7 PLC
Check the channel driver configuration in WinCC Explorer under 'Tag Management'. Verify the PLC IP address or PROFIBUS address. Use SIMATIC NET diagnostic tools or a ping test to confirm network connectivity to the PLC.
Correct the connection parameters in the WinCC channel configuration. Ensure the correct communication driver (e.g., SIMATIC S7 Protocol Suite) is installed and active. Check firewall settings on the WinCC PC that may be blocking industrial communication ports.
Historical trend data is not being recorded or is missing
Check the Tag Logging configuration to confirm that the relevant tags are assigned to a logging group with an appropriate cycle time. Verify that the SQL Server archive database has sufficient free disk space and that the Tag Logging runtime is active.
Increase available disk space on the archive drive. Restart the Tag Logging runtime from WinCC Explorer. If the database is corrupted, use the WinCC database tools to repair or recreate the archive database.
WinCC web clients cannot connect to the WinCC server
Verify that the WinCC Web Navigator server component is installed and the IIS (Internet Information Services) web server is running. Check that the correct port (typically TCP 80 or 443) is open in the Windows Firewall. Confirm that web client licenses are available in the Automation License Manager.
Restart the IIS service and the WinCC Web Navigator service. Ensure sufficient Web Navigator client licenses are installed. Verify that the WinCC project is published for web access and that the correct server hostname or IP address is used by the clients.
Alarm messages are displayed but not being archived
Check the Alarm Logging runtime status in WinCC Explorer. Verify that the alarm archive database in SQL Server is accessible and not full. Review the alarm logging configuration to confirm that archiving is enabled for the relevant alarm classes.
Free up disk space on the SQL Server database drive. Restart the Alarm Logging runtime. If the alarm database is corrupted, back up existing data and recreate the alarm archive using the WinCC configuration tools.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page