
Siemens 6AV6372-2DF07-0DH0 SIMATIC WinCC flexible
€ 3.137,00
The Siemens 6AV6372-2DF07-0DH0 is a software license for SIMATIC WinCC flexible 2007, Siemens' scalable HMI engineering software platform designed for configuring and commissioning operator panels and visualization systems within the SIMATIC automation environment. This part number corresponds to a specific edition of WinCC flexible 2007, used to create HMI projects for the full range of SIMATIC HMI panels including the OP, TP, MP, and Mobile Panel series. The software runs on standard engineering PCs under Windows and integrates tightly with the SIMATIC TIA and STEP 7 engineering environments.
WinCC flexible 2007 provides a comprehensive set of engineering tools including a graphical editor, tag management, alarm logging, trend displays, recipe management, and report generation. The software supports multiple communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and third-party controllers via PROFIBUS, MPI, PROFINET, and Ethernet interfaces. It offers a library of pre-built faceplates and symbols, multi-language project support, and simulation capabilities that allow project testing without physical hardware. The platform supports scalable licensing editions (Micro, Compact, Standard, Advanced) to match project complexity.
SIMATIC WinCC flexible is widely used in manufacturing, process automation, machine building, and plant engineering applications where operator interface configuration is required. It is particularly suited for OEMs and system integrators developing HMI solutions for packaging machinery, conveyor systems, press lines, and general-purpose industrial machines. The software's tight integration with Siemens controller hardware and its structured project management tools make it a standard choice for SIMATIC-based automation projects across industries including automotive, food and beverage, and chemical processing.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| Series/Product Family | SIMATIC WinCC flexible |
| License Type | Single-user engineering license |
| Supported Operating Systems | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Compatible HMI Panels | SIMATIC OP, TP, MP, Mobile Panel series |
| Controller Compatibility | SIMATIC S7-200, S7-300, S7-400, and third-party controllers |
| Communication Interfaces | MPI, PROFIBUS DP, PROFINET, Industrial Ethernet |
| Language Support | Multi-language project configuration |
| Integration | SIMATIC STEP 7, SIMATIC TIA environment |
| Simulation | Integrated HMI simulator for offline project testing |
| Certifications | CE |
| Delivery Format | Software license with installation media |
Common Error Codes & System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target panel.
Check that the correct Runtime version is installed on the HMI panel. Reload the project via ProSave or the Transfer function and restart the panel. - Event ID: 1003
- Communication error — No connection established between HMI panel and PLC.
Verify MPI/PROFIBUS address settings in the project match the physical network configuration. Check cable connections and confirm the PLC is in RUN mode. - Event ID: 1004
- Tag read/write error — A configured tag could not be read from or written to the controller.
Check that the tag address in the HMI project matches the actual data block or memory address in the PLC program. Verify data type consistency. - Event ID: 1010
- Transfer error — Project transfer to the HMI panel was interrupted or failed.
Ensure the panel is in Transfer mode before initiating download. Check the communication cable or Ethernet connection and retry the transfer using SIMATIC ProSave. - Event ID: 1020
- License error — No valid license found for WinCC flexible engineering software.
Use the Siemens Automation License Manager (ALM) to verify the license is correctly installed and assigned. Reinstall or transfer the license if necessary. - Event ID: 1030
- Project version mismatch — The project was created with a different version of WinCC flexible than the one installed.
Open the project in the correct version of WinCC flexible or use the migration wizard to upgrade the project to the installed software version. - Event ID: 1050
- Runtime memory overflow — Insufficient memory on the HMI panel to load the project.
Reduce the number of screens, images, or logged tags in the project. Check panel memory specifications and optimize project resources accordingly.
Frequently Asked Questions
Which edition of WinCC flexible does the 6AV6372-2DF07-0DH0 license correspond to?
The 6AV6372-2DF07-0DH0 is a license for SIMATIC WinCC flexible 2007. The specific edition (Micro, Compact, Standard, or Advanced) should be confirmed against the Siemens order documentation, as the part number suffix encodes the edition variant.
Is WinCC flexible 2007 compatible with TIA Portal projects?
WinCC flexible 2007 is not natively compatible with TIA Portal (WinCC Basic/Comfort/Advanced). Projects created in WinCC flexible can be migrated to TIA Portal using the integrated migration tool, but the two engineering environments are separate platforms.
Which SIMATIC HMI panels can be configured with this software?
WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, Mobile Panel 177, and other panels in the SIMATIC HMI family. It does not support Basic Panels, which require TIA Portal.
What communication protocols are supported for PLC connectivity?
WinCC flexible 2007 supports MPI, PROFIBUS DP, PROFINET IO, and Industrial Ethernet communication protocols, as well as drivers for third-party controllers from Allen-Bradley, Mitsubishi, Omron, and others.
Can WinCC flexible 2007 be installed on Windows 10?
WinCC flexible 2007 was qualified for Windows XP, Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10. For modern operating systems, Siemens recommends migrating to TIA Portal WinCC.
Troubleshooting
Project transfer to HMI panel fails repeatedly
Check whether the panel is correctly set to Transfer mode. Verify the communication interface settings (Ethernet IP address or MPI/PROFIBUS address) match those configured in the WinCC flexible project transfer settings.
Set the HMI panel to Transfer mode via the Start Center or Control Panel. Confirm IP address or bus address alignment between the engineering PC and the panel. Use SIMATIC ProSave as an alternative transfer tool if the WinCC flexible integrated transfer continues to fail.
WinCC flexible software does not start after installation
Check the Windows Event Viewer for application errors related to WinCC flexible startup. Verify that the Automation License Manager (ALM) service is running and that a valid license is present.
Restart the Automation License Manager service via Windows Services. If no valid license is detected, use ALM to reinstall or recover the license. Ensure the installation was performed with administrator privileges and that all prerequisite components (SQL Server, .NET Framework) are correctly installed.
Communication between HMI panel and S7 PLC is intermittent or drops frequently
Check the physical PROFIBUS or MPI cable for damage, correct termination resistors at both ends of the bus, and correct bus address assignments. For Ethernet connections, verify network switch configuration and IP addressing.
Replace damaged cables and ensure bus terminators are installed only at the physical ends of the PROFIBUS segment. Confirm that no two devices share the same bus address. For Ethernet, assign static IP addresses to both the PLC and HMI panel to avoid DHCP-related connectivity issues.
Alarm messages are not displayed on the HMI panel at runtime
Verify that alarm tags in the WinCC flexible project are correctly linked to the corresponding PLC bit addresses. Check that the alarm view or alarm window object is present and enabled on the relevant project screens.
Review the alarm configuration in WinCC flexible and confirm that each discrete alarm is mapped to the correct PLC tag and bit. Ensure the alarm view control is added to the screen and that its visibility property is not conditionally hidden. Retransfer the corrected project to the panel.
WinCC flexible project simulation fails or crashes on the engineering PC
Check available RAM and CPU resources on the engineering PC during simulation. Verify that no firewall or antivirus software is blocking the internal simulation communication ports used by WinCC flexible Runtime.
Close unnecessary applications to free system resources before starting the simulation. Add WinCC flexible and its Runtime components to the antivirus and firewall exception lists. If the issue persists, reinstall the WinCC flexible Runtime component using the original installation media.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page



