• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0DH4 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-2DF07-0DH4 SIMATIC WinCC

    € 1.761,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0DH4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0DH4 is a WinCC (Windows Control Center) runtime software license belonging to Siemens' SIMATIC HMI software family. WinCC is a supervisory control and data acquisition (SCADA) and human-machine interface (HMI) software platform designed for process visualization, monitoring, and control in industrial automation environments. This specific part number corresponds to a WinCC runtime package with a defined number of PowerTags, enabling process data visualization on standard PC-based hardware running Microsoft Windows.

    The WinCC runtime software supports a wide range of communication interfaces and drivers, including PROFIBUS, PROFINET, MPI, and OPC/OPC UA, enabling seamless integration with Siemens SIMATIC S7 PLCs and third-party controllers. It provides features such as alarm management, trend logging, historical data archiving, report generation, and user access control. The software supports redundant server configurations for high-availability applications and includes scripting capabilities via VBScript and C-Script for custom automation logic and screen interactions.

    WinCC runtime software is widely deployed in manufacturing, process industries, water and wastewater treatment, energy management, and building automation. Its scalable architecture makes it suitable for both standalone single-station installations and large distributed multi-client/server SCADA systems. The PC-based platform allows integration with enterprise-level IT systems, databases such as Microsoft SQL Server, and standard office applications for reporting and data analysis.

    Technical Specifications

    Software Type SCADA / HMI Runtime Software
    Product Family SIMATIC WinCC
    Platform PC-based (Microsoft Windows)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC, OPC UA
    PLC Compatibility Siemens SIMATIC S7-300, S7-400, S7-1200, S7-1500 and third-party via OPC
    Scripting Support VBScript, C-Script
    Database Microsoft SQL Server
    Redundancy Server redundancy supported
    Alarm Management Integrated alarm logging and archiving
    Trend Logging Historical and online trend display
    User Access Control Role-based user administration
    Certifications CE
    License Type Runtime license with defined PowerTag count
    Operating System Microsoft Windows (Server/Client editions)

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC runtime startup failure — the runtime could not initialize correctly, often due to missing or corrupt project files.
    Verify the WinCC project path is accessible, check Windows Event Viewer for detailed error messages, and ensure all required WinCC components are properly installed.
    Event ID: 1001
    Communication channel error — the configured communication driver cannot establish a connection to the target PLC or device.
    Check physical network connections, verify PLC address and communication parameters in the channel configuration, and confirm the PLC is powered and reachable.
    Event ID: 112
    Tag logging database error — WinCC cannot write to the SQL Server archive database.
    Verify that the Microsoft SQL Server service is running, check available disk space, and review SQL Server error logs for permission or connectivity issues.
    Event ID: 10241
    License not found — no valid WinCC runtime license was detected on the system.
    Insert the Siemens license key (USB dongle or software license), use Siemens Automation License Manager (ALM) to verify license status, and ensure the correct PowerTag count license is installed.
    Event ID: 10000
    Redundancy switchover event — the active WinCC server has failed and the standby server has taken over.
    Investigate the cause of the primary server failure, check network connectivity between redundant servers, and restore the primary server before performing a manual switchback.
    Communication Error
    OPC server connection lost — WinCC OPC client cannot reach the configured OPC server.
    Verify the OPC server is running, check DCOM security settings on both client and server machines, and confirm firewall rules allow OPC communication.
    Alarm: @System
    System alarm indicating WinCC internal process or service has stopped unexpectedly.
    Restart the affected WinCC service via the SIMATIC Shell or Windows Services manager, review the WinCC diagnostic log files for root cause, and apply any pending software patches.

    Frequently Asked Questions

    What is the PowerTag count for the 6AV6372-2DF07-0DH4 license?

    The 6AV6372-2DF07-0DH4 is a WinCC runtime license; the specific PowerTag count is encoded in the part number variant. Consult the Siemens WinCC ordering data or the Automation License Manager to confirm the exact tag count associated with this license key.

    Which Siemens PLCs are compatible with this WinCC runtime software?

    WinCC runtime is compatible with the full range of Siemens SIMATIC S7 PLCs including S7-300, S7-400, S7-1200, and S7-1500 via PROFIBUS, PROFINET, or MPI. Third-party PLCs and devices can be integrated using OPC or OPC UA communication channels.

    Does this WinCC runtime support redundant server configurations?

    Yes, WinCC supports server redundancy where a standby server automatically takes over if the active server fails, ensuring high availability for critical process monitoring applications.

    What operating system is required to run WinCC runtime?

    WinCC runtime requires a compatible version of Microsoft Windows, typically Windows 10 or Windows Server editions as specified in the Siemens WinCC system requirements for the installed software version.

    Can WinCC runtime be used with third-party SCADA or MES systems?

    Yes, WinCC supports OPC and OPC UA interfaces, as well as Microsoft SQL Server database connectivity, enabling integration with third-party MES, ERP, and SCADA systems.

    Troubleshooting

    WinCC runtime fails to start and displays a license error message

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC runtime license with sufficient PowerTags is present and not expired or transferred.

    Insert the correct USB license dongle or transfer the software license to the local machine using ALM. Ensure the license PowerTag count matches or exceeds the number of tags configured in the project.

    No communication between WinCC and the connected S7 PLC

    Check the channel diagnostics in WinCC Channel Diagnosis tool. Verify the IP address or MPI/PROFIBUS address configured in the WinCC tag management matches the actual PLC settings.

    Correct the communication parameters in WinCC tag management, verify physical network connections and switch/hub status, and confirm the PLC is in RUN mode and reachable via a ping test or STEP 7/TIA Portal online connection.

    Historical trend data or alarm archives are not being recorded

    Check whether the Microsoft SQL Server service is running via Windows Services. Review WinCC diagnostic logs for database write errors or disk space warnings.

    Restart the SQL Server service if stopped, free up disk space if the archive drive is full, and verify that the WinCC service account has sufficient permissions to write to the SQL Server database.

    WinCC screens load slowly or the runtime becomes unresponsive

    Monitor CPU and RAM usage on the PC using Windows Task Manager. Check the number of active tags and logging cycles configured in the project, as excessive polling rates can overload the system.

    Optimize tag update cycles by reducing unnecessary fast-cycle tags, increase PC RAM if below recommended specifications, and ensure no other resource-intensive applications are running concurrently on the WinCC server.

    User cannot log in to WinCC runtime — access denied error

    Check the WinCC User Administrator configuration to verify the user account exists, is enabled, and is assigned to the correct user group with the required authorizations.

    Re-create or unlock the user account in WinCC User Administrator, assign the appropriate authorization levels, and ensure the Windows user account running WinCC has the necessary local administrator or service permissions.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart