• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0CX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-2DF07-0CX0 SIMATIC WinCC

    € 1.865,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0CX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0CX0 is a WinCC (Windows Control Center) SCADA/HMI software package from Siemens, part of the SIMATIC HMI software family. This part number corresponds to a WinCC runtime or configuration software license, designed to run on standard industrial PCs and panel PCs for supervisory control and data acquisition applications. It belongs to the broader SIMATIC WinCC product line, which is one of the most widely deployed HMI/SCADA software platforms in industrial automation.

    The 6AV6372-2DF07-0CX0 provides a comprehensive engineering and runtime environment for creating and operating process visualization screens, alarm management, trend displays, and reporting functions. It supports communication with SIMATIC S7 PLCs via MPI, PROFIBUS, and Industrial Ethernet (PROFINET), as well as OPC DA/UA interfaces for third-party system integration. The software includes tag-based licensing, historical data archiving, user administration with access level control, and supports redundant server configurations for high-availability installations.

    This WinCC software package is used extensively in process industries such as chemical, pharmaceutical, water and wastewater treatment, food and beverage, and energy management. It is also deployed in discrete manufacturing environments for machine monitoring, production line visualization, and quality data acquisition. Its compatibility with the broader Siemens TIA Portal ecosystem and SIMATIC controller range makes it a natural choice for plants already operating Siemens automation infrastructure.

    Technical Specifications

    Software Platform SIMATIC WinCC
    Software Type HMI/SCADA Runtime and Configuration Software
    Operating System Compatibility Windows (Industrial PC / Panel PC)
    Communication Interfaces MPI, PROFIBUS, Industrial Ethernet (PROFINET), OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Redundancy Support Server redundancy supported
    Alarm Management Integrated alarm logging and archiving
    Trend/Archiving Process value archiving and trend display
    User Administration Multi-level user access control
    Reporting Integrated report generation
    Series/Product Family SIMATIC WinCC
    License Type Software license (tag-based)
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000000
    WinCC Runtime startup failure — the runtime system could not be started, often due to a missing or invalid license.
    Verify that a valid WinCC license is installed using the Siemens Automation License Manager. Reinstall the license if necessary.
    Event ID: 1001
    Communication error to PLC — the configured communication channel to the SIMATIC controller cannot be established.
    Check network or bus connections, verify the PLC address settings in WinCC Tag Management, and confirm the PLC is in RUN mode.
    Event ID: 10000
    Tag acquisition error — one or more process tags cannot be read from the connected controller.
    Check the tag configuration in WinCC Tag Management, verify PLC program variable addresses, and confirm communication driver status.
    Event ID: 100001
    Archive database error — the WinCC archive (process value or alarm archive) cannot be accessed or written to.
    Check available disk space, verify SQL Server service is running, and check database file integrity using WinCC diagnostics tools.
    Event ID: 2000
    User administration error — login failure or user rights configuration issue detected.
    Verify user account configuration in WinCC User Administrator. Reset user credentials if necessary and check access level assignments.
    Event ID: 3000
    OPC server connection failure — WinCC OPC DA or OPC UA server cannot be reached by the OPC client application.
    Verify OPC server configuration, check DCOM settings for OPC DA connections, and confirm firewall rules allow OPC communication on the required ports.
    Event ID: 5000
    Redundancy switchover event — WinCC has detected a failure on the primary server and switched to the redundant server.
    Investigate the cause of the primary server failure, restore the primary server to operational status, and perform a manual switchback if required.

    Frequently Asked Questions

    What type of license does the 6AV6372-2DF07-0CX0 provide?

    This part number corresponds to a WinCC software license, which is tag-based and managed via the Siemens Automation License Manager. The specific tag count and runtime scope are defined by the license variant encoded in the part number.

    Which SIMATIC PLCs are compatible with this WinCC software?

    WinCC is compatible with SIMATIC S7-300, S7-400, S7-1200, and S7-1500 controllers via MPI, PROFIBUS, or Industrial Ethernet (PROFINET). Third-party PLCs can also be integrated via OPC DA or OPC UA interfaces.

    Can WinCC 6AV6372-2DF07-0CX0 be used in a redundant server configuration?

    Yes, WinCC supports server redundancy configurations where a standby server automatically takes over if the primary server fails, ensuring high availability for critical process visualization applications.

    What operating system is required to run this WinCC software?

    WinCC requires a Windows-based operating system, typically Windows 10 or Windows Server, running on an industrial PC or Siemens panel PC that meets the minimum hardware requirements specified in the WinCC release notes.

    Does this software support OPC UA communication?

    Yes, WinCC includes an integrated OPC UA server and client, allowing data exchange with third-party systems and controllers that support the OPC UA standard.

    Troubleshooting

    WinCC Runtime fails to start after installation

    Check the Siemens Automation License Manager to confirm a valid license is present and not expired. Review the WinCC diagnostic log files located in the WinCC installation directory for specific error messages.

    Install or transfer a valid WinCC license using the Automation License Manager. If the license is present but invalid, contact Siemens licensing support. Ensure all prerequisite software components including Microsoft SQL Server are correctly installed.

    No communication between WinCC and SIMATIC PLC

    Verify the communication driver configuration in WinCC Tag Management. Check that the PLC IP address or MPI/PROFIBUS address is correctly configured. Use the Siemens communication diagnostic tools (e.g., STEP 7 or TIA Portal) to confirm the PLC is reachable from the PC.

    Correct the channel and connection settings in WinCC Tag Management. Verify network cabling and switch configuration. Ensure the PC network adapter is configured with a compatible IP address and subnet mask. Restart the WinCC channel driver after making changes.

    Process values are not updating on WinCC screens

    Check the tag status in the WinCC Tag Management or use the WinCC Data Monitor to verify whether tags are returning valid values or error states. Confirm that the PLC program is writing to the expected data addresses.

    Correct any address mismatches between WinCC tag configuration and PLC variable addresses. Restart the affected communication driver. If the issue persists, check for PLC program faults that may be preventing data updates.

    WinCC archive database errors or missing historical data

    Check available disk space on the drive hosting the WinCC archive database. Verify that the Microsoft SQL Server service is running via Windows Services. Review the WinCC system event log for database-related error entries.

    Free up disk space if storage is insufficient. Restart the SQL Server service if it has stopped. Use the WinCC Database Compressor tool to compact archive databases. If database files are corrupted, restore from a recent backup.

    WinCC alarms are not being displayed or acknowledged

    Check the alarm configuration in WinCC Alarm Logging to confirm that alarm classes and groups are correctly defined. Verify that the alarm server is running within the WinCC runtime environment.

    Restart the WinCC Alarm Logging server component. Verify alarm tag connections and threshold values in the alarm configuration. Ensure the operator account has sufficient access rights to view and acknowledge alarms in the User Administrator settings.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart