Siemens 6AV6371-1KG07-5AX3 WinCC flexible 2007
€ 125,00
The Siemens 6AV6371-1KG07-5AX3 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for creating and managing HMI (Human-Machine Interface) projects on Siemens SIMATIC panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is used to develop visualization solutions for industrial automation systems.
WinCC flexible 2007 (6AV6371-1KG07-5AX3) offers a comprehensive set of engineering tools for designing operator screens, configuring alarms, managing tags, and setting up communication with SIMATIC PLCs and third-party controllers. The software supports a wide range of communication drivers including PROFIBUS, PROFINET, MPI, and Industrial Ethernet, enabling seamless integration with S7-200, S7-300, S7-400, and other SIMATIC controller families. It includes features such as faceplates, script support, recipe management, trend displays, and multi-language project support, making it suitable for complex HMI application development.
WinCC flexible 2007 is used across a broad range of industries including automotive manufacturing, food and beverage processing, chemical and pharmaceutical production, and machine building. It is particularly well suited for OEMs and system integrators who need to develop standardized HMI solutions deployable across multiple panel types, from small Micro panels to high-performance Multi Panels and PC-based runtime environments. The software's scalability and compatibility with the SIMATIC HMI hardware range make it a practical choice for both standalone machine-level visualization and larger distributed control architectures.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| License Type | Engineering Software License |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, S7-1200 (with restrictions) |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, Industrial Ethernet |
| Supported Panel Families | SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC Runtime |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Language Support | Multi-language project configuration |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
| Integration | SIMATIC Manager, STEP 7 integration supported |
Common Error Codes & System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
Check that the correct Runtime version is installed on the target panel or PC. Verify license availability and re-transfer the project. - Event ID: 2501
- Communication error — No connection established to the configured PLC or controller.
Verify network cabling and communication settings (IP address, MPI address, PROFIBUS address). Check that the PLC is powered and in RUN mode. - Event ID: 3000
- Tag read/write error — A configured tag could not be read from or written to the controller.
Check the tag address configuration in the WinCC flexible project. Verify the corresponding data block or memory area exists in the PLC program. - Event ID: 4010
- License not found — No valid license detected for WinCC flexible Engineering or Runtime.
Install the correct license using the Siemens Automation License Manager (ALM). Ensure the license matches the software version and edition. - Event ID: 5100
- Project transfer error — Project could not be transferred to the target HMI panel.
Check the transfer connection (USB, Ethernet, or MPI). Ensure the panel is in Transfer mode and that the correct communication channel is selected in the transfer settings. - Event ID: 6200
- Alarm buffer overflow — The alarm buffer on the HMI device has reached its maximum capacity.
Acknowledge and clear pending alarms. Review alarm configuration to reduce unnecessary alarm generation or increase the alarm buffer size in the project settings. - Event ID: 7300
- Recipe data error — Recipe records could not be read or written correctly.
Verify the recipe configuration and associated tag addresses. Check available storage memory on the target device and ensure the recipe data format matches the project definition.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2007?
WinCC flexible 2007 supports the full range of SIMATIC HMI panels including Micro Panels (TP 170 Micro, TP 177 Micro), Mobile Panels, Operator Panels (OP 77, OP 177), Multi Panels (MP 277, MP 377), and PC-based Runtime environments. Compatibility depends on the specific edition of WinCC flexible 2007 installed.
Is WinCC flexible 2007 compatible with Windows 10?
WinCC flexible 2007 is not officially supported on Windows 10. It was designed for Windows XP, Windows Vista, and Windows 7 (32-bit). For Windows 10 compatibility, Siemens recommends migrating to WinCC (TIA Portal).
Can WinCC flexible 2007 projects be migrated to TIA Portal?
Yes, WinCC flexible 2007 projects can be migrated to WinCC in TIA Portal using the TIA Portal migration tool. Some manual rework may be required depending on the complexity of the project and the features used.
What communication protocols does WinCC flexible 2007 support?
WinCC flexible 2007 supports PROFIBUS DP, PROFINET, MPI, Industrial Ethernet (TCP/IP), and a range of third-party communication drivers. It also supports OPC DA for integration with non-Siemens systems.
What is the difference between WinCC flexible Engineering and WinCC flexible Runtime?
WinCC flexible Engineering is the development environment used to create and configure HMI projects on a PC. WinCC flexible Runtime is the execution environment installed on the target HMI panel or PC that runs the finished project. The 6AV6371-1KG07-5AX3 license covers the Engineering software.
Troubleshooting
WinCC flexible 2007 fails to install or reports a license error after installation
Check whether the Automation License Manager (ALM) is installed and detects the license. Verify that the license matches the installed software version and edition.
Install or reinstall the Automation License Manager. Transfer the correct license using ALM. If using a USB dongle, ensure it is properly connected and recognized by the operating system.
Project cannot be transferred to the HMI panel
Verify the communication channel selected in Transfer Settings matches the physical connection (USB, Ethernet, or MPI/PROFIBUS). Check that the panel is set to Transfer mode.
Set the HMI panel to Transfer mode via its Start Center. Confirm IP address or bus address settings match the project configuration. Try an alternative transfer cable or connection method if the issue persists.
Runtime on the HMI panel shows 'No connection to PLC' or tags display '####'
Check the PLC communication settings in the WinCC flexible project, including the IP address, MPI address, or PROFIBUS address. Verify physical network connections and PLC operating state.
Correct the communication parameters in the project and re-transfer. Inspect Ethernet or PROFIBUS cabling. Ensure the PLC is powered on and in RUN or STOP mode as required.
WinCC flexible Engineering software crashes or becomes unstable on the engineering PC
Check the operating system compatibility. WinCC flexible 2007 is supported on Windows XP and Windows 7 (32-bit) only. Conflicts with other installed software or insufficient system resources may also cause instability.
Ensure the engineering PC runs a supported 32-bit operating system. Uninstall conflicting software. Apply the latest Siemens service packs and patches for WinCC flexible 2007 available via the Siemens Industry Online Support portal.
Alarms are not displayed correctly or alarm history is missing on the HMI panel
Check the alarm configuration in the project, including alarm classes, triggers, and the alarm buffer size. Verify that the alarm server connection is active if using a networked alarm system.
Review and correct alarm tag addresses and trigger conditions in the WinCC flexible project. Increase the alarm buffer size if overflow events are logged. Re-transfer the updated project to the panel.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page