• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1CD01-1PX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6371-1CD01-1PX0 SIMATIC WinCC

    € 853,00

    Reset
    Clear
    SKU: 6AV6371-1CD01-1PX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1CD01-1PX0 is a WinCC (Windows Control Center) runtime software license belonging to Siemens' SIMATIC HMI software family. It is a SCADA and HMI visualization software package designed to run on standard PC-based hardware, enabling operators to monitor and control industrial processes through graphical user interfaces. This part number corresponds to a WinCC Runtime license with a defined number of power tags, used for process visualization in PC-based automation environments.

    WinCC Runtime software provides a comprehensive set of features including process visualization, alarm management, historical data logging, trend displays, and report generation. It supports a wide range of communication interfaces and drivers for connecting to Siemens SIMATIC S7 PLCs as well as third-party controllers via OPC DA/UA, PROFIBUS, PROFINET, and Industrial Ethernet. The software integrates with the SIMATIC automation ecosystem and supports redundant server configurations, multi-client architectures, and web-based client access for distributed monitoring.

    The 6AV6371-1CD01-1PX0 is typically deployed in process industries such as water and wastewater treatment, chemical and pharmaceutical manufacturing, food and beverage production, and energy management facilities. Its PC-based architecture makes it suitable for applications requiring complex data logging, advanced reporting, and integration with enterprise-level IT systems such as MES and ERP platforms. The scalable tag-based licensing model allows it to be adapted to both small standalone installations and large distributed control system architectures.

    Technical Specifications

    Software Type WinCC Runtime (SCADA/HMI Visualization)
    Platform PC-based (Windows OS)
    Communication Interfaces PROFIBUS, PROFINET, Industrial Ethernet, OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500, and third-party via OPC
    Architecture Support Single-station, client/server, redundant server
    Data Logging Supported (process values, alarms, events)
    Alarm Management Integrated alarm logging and reporting
    Trend Display Supported
    Web Client Access Supported via WinCC Web Navigator (optional)
    Series/Product Family SIMATIC WinCC
    Certifications CE
    Operating System Microsoft Windows (version per release requirements)

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup error — the runtime could not be initialized, often due to licensing or configuration issues.
    Verify that the WinCC license (AuthorsW/SIMATIC Logon) is correctly installed and not expired. Check the WinCC project configuration for errors.
    Event ID: 1001
    Communication error to PLC — the configured communication channel to the controller has failed or timed out.
    Check network connectivity between the WinCC PC and the PLC. Verify the channel driver configuration, IP address settings, and that the PLC is in RUN mode.
    Event ID: 112
    Tag logging error — process values could not be written to the archive database.
    Check available disk space on the WinCC server. Verify that the SQL Server service (SIMATIC WinCC SQL Server) is running and the archive database is not corrupt.
    Event ID: 10000
    License not found — no valid WinCC Runtime license was detected on the system.
    Install or transfer the correct WinCC Runtime license using the Automation License Manager (ALM). Ensure the license matches the required power tag count.
    Event ID: 1003
    OPC server connection failure — WinCC cannot connect to the configured OPC DA or OPC UA server.
    Verify the OPC server is running and accessible. Check DCOM settings for OPC DA connections or endpoint configuration for OPC UA. Ensure firewall rules permit the connection.
    Event ID: 2000
    Redundancy switchover event — the WinCC redundant server has switched from master to standby due to a detected fault.
    Investigate the primary server for hardware or software faults. Check the WinCC Redundancy diagnostics and restore the primary server before performing a manual switchback.
    Event ID: 1008
    Project activation failed — WinCC Runtime could not activate the configured project.
    Check the WinCC project for configuration errors using WinCC Configuration Studio. Ensure all required drivers and scripts compile without errors before reactivating.

    Frequently Asked Questions

    What is the power tag count for the 6AV6371-1CD01-1PX0 license?

    The 6AV6371-1CD01-1PX0 corresponds to a WinCC Runtime license; the specific power tag count (e.g., 128, 512, 2048 tags) is defined by the license variant. Refer to the Siemens SIMATIC WinCC ordering data or the Automation License Manager to confirm the exact tag count for this part number.

    What operating system is required to run this WinCC Runtime software?

    WinCC Runtime requires a compatible Microsoft Windows operating system, typically Windows 10 (64-bit) or Windows Server editions, depending on the WinCC version. Refer to the Siemens WinCC compatibility list for the specific OS requirements matching the software version supplied.

    Can this WinCC Runtime license be used in a client/server architecture?

    Yes, WinCC Runtime supports client/server architectures where one or more WinCC clients connect to a WinCC server. Additional client licenses (WinCC RT Client) are required for each connected client workstation.

    How is the WinCC license managed and transferred?

    WinCC licenses are managed using the Siemens Automation License Manager (ALM) software. Licenses can be stored on a USB dongle or bound to a specific PC, and can be transferred between systems using ALM.

    Is this software compatible with SIMATIC S7-1500 PLCs?

    Yes, WinCC Runtime supports communication with SIMATIC S7-1500 PLCs via PROFINET/Industrial Ethernet using the SIMATIC S7 channel driver or OPC UA, provided the appropriate communication driver is installed and configured.

    Troubleshooting

    WinCC Runtime fails to start and displays a licensing error

    Open the Automation License Manager (ALM) and check whether a valid WinCC Runtime license is present and not expired or over-counted. Check the Windows Event Viewer for WinCC-related error entries.

    Install or restore the correct WinCC Runtime license via ALM. If the license is stored on a USB dongle, ensure the dongle is connected. If the license is corrupted, contact Siemens support for license recovery.

    Process tags show no current values and display dashes or error symbols

    Check the WinCC channel diagnostics in the WinCC Explorer to identify which communication channel is reporting errors. Verify PLC connectivity by pinging the PLC IP address from the WinCC PC.

    Restore network connectivity between the WinCC PC and the PLC. Verify the channel driver configuration including IP address, rack, and slot settings. Restart the WinCC channel driver if necessary.

    Alarm logging stops recording new alarms

    Check available disk space on the drive hosting the WinCC project and SQL Server database. Verify that the SIMATIC WinCC SQL Server service is running in Windows Services.

    Free up disk space or expand storage. Restart the SIMATIC WinCC SQL Server service if it has stopped. If the alarm archive is corrupt, use the WinCC database tools to repair or reinitialize the archive.

    WinCC project cannot be activated after configuration changes

    Review the WinCC output window for compilation errors in scripts (VBScript/C-Script) or configuration inconsistencies. Check that all referenced tags and screens exist in the project.

    Correct any script compilation errors identified in the output window. Ensure all tag connections reference valid PLC addresses. Recompile the project and attempt activation again.

    Web clients cannot connect to the WinCC Web Navigator server

    Verify that the WinCC Web Navigator server component is installed and the IIS (Internet Information Services) web service is running. Check firewall rules on the WinCC server for HTTP/HTTPS ports.

    Ensure IIS is running and the WinCC Web Navigator virtual directory is correctly configured. Open the required HTTP (port 80) or HTTPS (port 443) ports in the Windows Firewall. Verify client browser compatibility with the installed Web Navigator version.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart