
Siemens 6AV6371-1AF00-0AX0 WinCC flexible 2005
€ 1.700,00
The Siemens 6AV6371-1AF00-0AX0 is a software license for WinCC flexible 2005, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure, program, and commission Siemens HMI panels, including the OP, TP, MP, and Mobile Panel series. It is designed for use on standard engineering PCs running compatible Windows operating systems.
WinCC flexible 2005 offers a project-based engineering approach with a library of pre-built faceplates, tag management, alarm logging, and recipe handling capabilities. The software supports communication with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It includes integrated simulation tools that allow operators to test HMI projects on the engineering PC before downloading to the target panel, reducing commissioning time.
This software is used across a wide range of industrial automation applications including machine tool control, packaging machinery, process plants, and material handling systems. It is particularly suited for OEMs and system integrators who need to develop standardized HMI solutions across multiple Siemens panel types. The WinCC flexible 2005 platform provides a scalable engineering environment that supports projects ranging from small operator panels to multi-panel SCADA-level installations.
Technical Specifications
| Software Version | WinCC flexible 2005 |
|---|---|
| License Type | Single-user engineering license |
| Compatible HMI Panels | SIMATIC OP, TP, MP, Mobile Panel series |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet |
| Operating System | Windows XP, Windows 2000 Professional |
| Simulation | Integrated PC-based HMI simulation |
| Tag Management | Supported |
| Alarm Logging | Supported |
| Recipe Handling | Supported |
| Series | WinCC flexible |
| Certifications | CE |
Common Error Codes and Software Events
- Error 1
- License not found or invalid license key detected during software startup
Verify the license dongle or software license is correctly installed using the Siemens Automation License Manager (ALM). Reinstall the license if necessary. - Error 2
- Project compilation error due to inconsistent tag references or missing connections
Open the project in WinCC flexible, navigate to the compiler output window, and resolve all flagged tag or connection inconsistencies before recompiling. - Error 3
- Communication error between engineering PC and HMI panel during download
Check the physical connection cable and interface settings. Verify the correct communication channel (MPI, PROFIBUS, or Ethernet) is configured in the project transfer settings. - Error 4
- Incompatible project version detected when opening a project created in a different WinCC flexible version
Use the project migration wizard within WinCC flexible to convert the project to the current version. Back up the original project before migration. - Error 5
- Simulation runtime crash or failure to launch the integrated simulator
Ensure the engineering PC meets the minimum hardware requirements. Reinstall the WinCC flexible runtime simulation component if the issue persists. - Error 6
- Panel type mismatch: project configured for a different HMI device than the connected target panel
Verify the target device type in the project settings matches the physical HMI panel. Use the device change wizard to migrate the project to the correct panel type. - Error 7
- Automation License Manager (ALM) reports license in use or license transfer failure
Open ALM and check the license status. If the license is locked to another PC, use the ALM transfer function to move the license to the current engineering station.
Frequently Asked Questions
Which Siemens HMI panels are supported by WinCC flexible 2005?
WinCC flexible 2005 supports the SIMATIC OP, TP, MP, and Mobile Panel series of HMI devices. This includes panels such as the TP177, OP177, MP277, and MP377 among others.
What PLC communication protocols does WinCC flexible 2005 support?
The software supports MPI, PROFIBUS DP, and Industrial Ethernet for communication with SIMATIC S7-200, S7-300, and S7-400 PLCs. Additional third-party drivers may also be available depending on the configuration.
Can WinCC flexible 2005 projects be migrated to newer WinCC flexible versions?
Yes, WinCC flexible includes a project migration wizard that allows projects created in earlier versions to be converted for use with newer versions of the software. It is recommended to back up the original project before migration.
Is a hardware dongle required to run WinCC flexible 2005?
WinCC flexible 2005 requires a valid license managed through the Siemens Automation License Manager (ALM). Depending on the license type, this may be tied to a hardware dongle or a software-based license key.
Does WinCC flexible 2005 include a simulation function?
Yes, WinCC flexible 2005 includes an integrated simulation tool that allows HMI projects to be tested on the engineering PC without requiring a physical HMI panel, which is useful for pre-commissioning validation.
Troubleshooting
Software fails to start and displays a license error message
Check the Siemens Automation License Manager (ALM) to determine whether a valid WinCC flexible 2005 license is present and not expired or locked to another machine.
Reinstall or transfer the license using ALM. Ensure the license dongle is connected if a hardware-based license is used, and that the dongle drivers are correctly installed.
Project download to HMI panel fails with a communication timeout error
Verify the physical connection between the engineering PC and the HMI panel. Check that the correct communication interface and baud rate are selected in the transfer settings within WinCC flexible.
Replace or reseat the communication cable. Confirm the HMI panel is in transfer mode and that the PC interface settings match the panel configuration. For Ethernet transfers, verify IP address settings on both devices.
Compiled project generates multiple tag errors and will not compile successfully
Open the compiler output log in WinCC flexible and review each flagged error. Common causes include deleted or renamed tags still referenced in screens or scripts, and missing PLC connection definitions.
Resolve each compiler error by updating or removing invalid tag references. Ensure all PLC connections are correctly defined and that tag addresses match the PLC data block structure.
Integrated simulator crashes or does not launch when testing a project
Check that the engineering PC meets the minimum system requirements for WinCC flexible 2005. Verify that no conflicting software or incomplete installation components are present.
Perform a repair installation of WinCC flexible 2005 using the original installation media. Ensure all required runtime simulation components are selected during the repair process.
Existing project cannot be opened and reports a version incompatibility error
The project was likely created in a different version of WinCC flexible that is not directly compatible with the installed version 2005.
Use the WinCC flexible project migration wizard to convert the project. If the project was created in a newer version, a downgrade may not be possible and the project may need to be recreated or the software version upgraded.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page



