• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1AD10-0AX0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6371-1AD10-0AX0 WinCC flexible 2007

    € 1.207,00

    Reset
    Clear
    SKU: 6AV6371-1AD10-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1AD10-0AX0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for designing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is used to create visualization projects for operator panels.

    WinCC flexible 2007 offers a comprehensive set of engineering tools including drag-and-drop screen design, tag management, alarm logging, trend displays, and recipe management. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces. It includes a library of pre-built faceplates and symbols, supports multi-language project configuration, and provides simulation capabilities for offline testing of HMI projects before deployment.

    This software is widely used in manufacturing automation, process control, and machine building applications where operator visualization and control are required. It is suitable for industries such as automotive, food and beverage, packaging, and water treatment, where reliable HMI engineering tools are needed to configure panel-based operator interfaces. The software is typically installed on an engineering PC and used to develop projects that are then downloaded to compatible Siemens HMI hardware targets.

    Technical Specifications

    Software Version WinCC flexible 2007
    License Type Single-user engineering license
    Compatible PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Supported HMI Targets SIMATIC Panels, Multi Panels, Mobile Panels, PC-based HMI
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Project Simulation Integrated offline simulator included
    Alarm Management Supported (discrete and analog alarms)
    Recipe Management Supported
    Trend Display Supported
    Multi-language Support Yes, multiple project languages configurable
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes and Software Events

    Error 1920
    License not found or license server unreachable at software startup.
    Verify that the license key (dongle or software license) is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary.
    Error 1722
    Windows Installer package error during installation, indicating a problem with the setup package or system configuration.
    Ensure the operating system meets minimum requirements. Run the installer as Administrator and disable antivirus software temporarily during installation.
    Communication Error
    No communication established between WinCC flexible engineering station and the target HMI panel during project download.
    Check the physical connection (USB, MPI, or Ethernet cable). Verify the correct communication channel and baud rate are configured in the transfer settings. Ensure the panel is in transfer mode.
    Compiler Error
    Project compilation fails due to inconsistent tag references or missing screen objects.
    Review the compiler output log for specific object references. Delete and re-create affected tags or screen objects. Ensure all referenced tags exist in the tag table.
    Runtime License Missing
    WinCC flexible Runtime reports missing or invalid license on the target panel or PC.
    Use the Automation License Manager to verify and assign the correct runtime license to the target device. Ensure the license matches the runtime version installed.
    Simulation Abort
    Integrated simulator terminates unexpectedly during offline simulation of the HMI project.
    Check for unresolved script errors or circular tag references in the project. Update WinCC flexible to the latest service pack and verify system RAM meets minimum requirements.
    Import/Export Error
    Failure during import or export of project data (tags, texts, or alarms) via Excel or CSV.
    Ensure the import file format matches the WinCC flexible template exactly. Check for special characters or encoding issues in the source file and re-save in UTF-8 or ANSI format as required.

    Frequently Asked Questions

    Which PLC families are compatible with WinCC flexible 2007?

    WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces.

    What operating systems are supported for installing WinCC flexible 2007?

    The software is compatible with Windows XP (SP3), Windows Vista, and Windows 7 (32-bit editions). It is not natively supported on 64-bit operating systems without compatibility settings.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted, though some manual rework may be required for complex projects.

    Does the 6AV6371-1AD10-0AX0 include a runtime license?

    The 6AV6371-1AD10-0AX0 is an engineering software license for project configuration. Separate runtime licenses are required for deploying projects on PC-based HMI targets.

    Is offline simulation of HMI projects possible without a physical panel?

    Yes, WinCC flexible 2007 includes an integrated simulator that allows full offline testing of HMI projects on the engineering PC without requiring a connected panel.

    Troubleshooting

    Software fails to start after installation and reports a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2007 engineering license is present and assigned to the local computer.

    Transfer or activate the correct license using ALM. If using a USB dongle, ensure it is properly inserted and recognized by the operating system before launching the software.

    Project download to HMI panel fails with a communication timeout

    Verify the physical connection between the PC and the panel (USB, MPI adapter, or Ethernet). Check that the panel is set to transfer mode and that the correct interface is selected in the WinCC flexible transfer settings.

    Correct the communication channel settings, ensure the panel is in transfer mode, and retry the download. Replace the communication cable if hardware faults are suspected.

    Compiler reports errors on previously working project after software update

    Check the compiler log for specific object or tag references that are flagged. Software updates may introduce stricter validation rules that expose previously ignored inconsistencies.

    Resolve each flagged item in the compiler log by correcting tag names, removing duplicate entries, or updating deprecated functions. Recompile after each correction to isolate remaining issues.

    Screens display incorrectly or objects are misaligned after opening an older project

    Older projects created in earlier WinCC flexible versions may have resolution or font compatibility issues when opened in WinCC flexible 2007.

    Review and adjust screen resolution settings in the project properties to match the target panel. Manually realign affected objects and verify font availability on the engineering PC.

    Simulation crashes immediately when started

    Check system RAM availability and review the project for unresolved script errors or missing tag references that may cause the simulator to abort during initialization.

    Free up system resources by closing other applications, resolve all compiler warnings and errors before starting simulation, and ensure the latest WinCC flexible 2007 service pack is installed.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart