• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-4AA00-0AA2 OP 77A
    Awaiting product image

    Siemens 6AV6355-4AA00-0AA2 OP 77A

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6355-4AA00-0AA2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-4AA00-0AA2 is the OP 77A operator panel, part of the SIMATIC HMI Basic Panels product family from Siemens. This compact operator panel is designed for straightforward machine-level human-machine interface tasks, providing a text-based display for process visualization and operator control. It belongs to the entry-level segment of the SIMATIC HMI portfolio, offering reliable performance for applications where graphical displays are not required.

    The OP 77A features a 4-line text display capable of showing alphanumeric characters, along with a membrane keypad for operator input including function keys and system keys. It communicates via the MPI/PROFIBUS DP interface, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible Compact or Standard engineering software, and supports alarm management, recipe handling, and simple process value display. The unit operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.

    The OP 77A is widely used in manufacturing and process automation environments where cost-effective, text-based operator interfaces are sufficient. Typical applications include machine tool control panels, conveyor systems, packaging machinery, and small-scale process control installations. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine enclosures across industries such as automotive, food and beverage, and general manufacturing.

    Technical Specifications

    Display Type Text display, 4-line alphanumeric
    Display Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Permissible Voltage Range 19.2 V DC to 28.8 V DC
    Power Consumption Max. 4 W
    Communication Interface MPI / PROFIBUS DP (RS-485)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible Compact / Standard
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 77A and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect the communication cable for damage or loose connectors. Check network topology and bus termination. Restart the panel and PLC if the connection is not re-established automatically.
    Event ID: 20000
    Configuration error detected. The project loaded on the panel is incompatible or corrupt.
    Re-download the project from WinCC flexible to the panel. Verify the project was compiled without errors before transfer.
    Event ID: 40000
    Operator panel internal error or system fault detected.
    Perform a power cycle on the panel. If the error persists, perform a factory reset and re-download the project. Contact Siemens support if the fault recurs.
    Event ID: 50000
    Recipe data error. A recipe record could not be read or written correctly.
    Check recipe configuration in WinCC flexible. Verify that recipe data areas in the PLC data blocks are correctly mapped and accessible.
    Event ID: 60000
    Alarm buffer overflow. The number of pending alarms exceeds the panel buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration to reduce the number of simultaneously active alarms or increase acknowledgement frequency.
    Event ID: 70000
    Tag update error. One or more process tags could not be updated within the configured cycle time.
    Reduce the number of tags or increase the update cycle time in the project configuration. Check PLC scan time and communication load on the MPI/PROFIBUS network.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A (6AV6355-4AA00-0AA2)?

    The OP 77A is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via the MPI or PROFIBUS DP interface. It can also communicate with S7-200 via the PPI protocol depending on configuration.

    What software is used to configure and program the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible Compact or WinCC flexible Standard engineering software. Projects are downloaded to the panel via the MPI interface or a PC adapter cable.

    What is the supply voltage for the OP 77A?

    The OP 77A requires a 24 V DC supply voltage, with a permissible operating range of 19.2 V DC to 28.8 V DC.

    What is the front panel protection rating of the OP 77A?

    The front face of the OP 77A is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for panel-mount installations in industrial environments.

    Can the OP 77A display graphical content or images?

    No, the OP 77A is a text-based operator panel with a 4-line alphanumeric display. It does not support graphical or bitmap image display. For graphical HMI functionality, a panel from the SIMATIC TP or MP series would be required.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the voltage is within the 19.2 V to 28.8 V range. Inspect the supply cable and connector for damage.

    Restore the correct supply voltage. If voltage is present and the display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair or replacement.

    Panel shows communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP address configured on the panel matches the network settings. Check that the bus cable is properly terminated at both ends and that no cable is damaged or disconnected.

    Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged cables and ensure proper bus termination resistors are installed at the physical ends of the network segment.

    Keypad buttons are unresponsive or intermittently fail

    Inspect the membrane keypad for physical damage, contamination, or wear. Test each key systematically in the panel's key test mode if available. Check for any visible damage to the keypad overlay.

    Clean the keypad surface with a dry cloth. If individual keys have failed due to wear, the membrane keypad assembly should be replaced. This is a common wear item on operator panels with high usage.

    Project download from WinCC flexible fails or times out

    Check the PC adapter cable connection between the engineering PC and the panel MPI port. Verify the correct COM port and transfer speed are selected in WinCC flexible transfer settings. Ensure the panel is in transfer mode.

    Switch the panel to transfer mode manually via the panel menu. Try a lower baud rate for the transfer. Replace the PC adapter cable if communication cannot be established after verifying all settings.

    Alarm messages are not displayed or are displayed incorrectly

    Check the alarm configuration in the WinCC flexible project, including the PLC bit addresses assigned to each alarm. Verify that the PLC data area used for alarms is being written correctly by the PLC program.

    Correct any incorrect tag or address assignments in the alarm configuration and re-download the project. Confirm the PLC logic is setting and resetting alarm bits as intended using the PLC programming software online monitor.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart