
Siemens 6AV6355-1CA47-7DC1 OP 77B
€ 1.309,77
The Siemens 6AV6355-1CA47-7DC1 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a keypad-based interface for process monitoring and control. It is part of the SIMATIC HMI Basic Panels generation and is manufactured by Siemens AG as a robust front-panel-mount device.
The OP 77B features a monochrome STN LCD display and a membrane keypad with function keys, system keys, and numeric entry keys for operator input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. Configuration is carried out using Siemens WinCC flexible software, and the panel includes onboard flash memory for project storage. The unit operates on a 24 V DC supply and is rated to IP65 at the front panel for protection against dust and water ingress.
The OP 77B is widely used in manufacturing automation, machine building, and process control applications where a cost-effective, reliable operator interface is required. It is particularly suited for applications in the packaging, automotive supply, and general machinery sectors where keypad-based operation is preferred over touchscreen interaction. Its compact form factor and compatibility with the SIMATIC S7 controller family make it a practical choice for panel integration in space-constrained environments.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Size | 4 inches |
| Input Voltage | 24 V DC |
| Voltage Range | 19.2 V DC – 28.8 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 %, non-condensing |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible 2008 or later |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Certifications | CE, UL, cULus |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to the PLC was interrupted during runtime operation.
Inspect the communication cable for damage or loose connectors. Check bus termination and cable shielding. Restart the HMI panel and PLC if the connection is not restored automatically. - Event ID: 20000
- Project download error. The project could not be transferred to the panel successfully.
Verify the PC-to-panel connection cable is functioning. Ensure WinCC flexible is configured with the correct transfer settings and COM port or MPI address. Retry the download after restarting the panel in transfer mode. - Event ID: 40000
- System memory low. Available memory on the panel is insufficient for the current project or runtime operation.
Reduce the project size by removing unused screens, tags, or graphics. Recompile and re-download the project using WinCC flexible. - Event ID: 50000
- Operating system error or internal panel fault detected during startup or runtime.
Perform a panel reset by cycling power. If the fault persists, restore the panel operating system using the ProSave tool via a serial or MPI connection. - Event ID: 60000
- Tag read/write error. The HMI panel cannot read from or write to a configured PLC tag.
Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check PLC program to ensure the address is accessible and not write-protected. - Event ID: 70000
- Recipe data error. A recipe transfer to or from the PLC has failed.
Check that the recipe tag addresses are correctly configured and accessible in the PLC. Verify available panel memory and re-attempt the recipe transfer.
Frequently Asked Questions
What communication interfaces does the OP 77B (6AV6355-1CA47-7DC1) support?
The OP 77B supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to Siemens S7-200, S7-300, and S7-400 series PLCs.
What software is required to configure this HMI panel?
The panel is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are compiled in WinCC flexible and downloaded to the panel via MPI or a serial transfer cable.
What is the supply voltage for the 6AV6355-1CA47-7DC1?
The panel requires a 24 V DC supply voltage, with an acceptable operating range of 19.2 V DC to 28.8 V DC.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B is rated to IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.
Can this panel be used as a replacement for an older OP7 or OP17 panel?
The OP 77B is designed as a functional successor to older SIMATIC operator panels such as the OP7 and OP17. However, projects must be migrated and recompiled in WinCC flexible, as direct project compatibility with older configuration tools is not supported.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel power connector. Check that the voltage is within the 19.2 V to 28.8 V range. Inspect the connector for correct polarity and secure contact.
Correct any supply voltage issues or wiring faults. If the supply is confirmed correct and the display remains blank, the internal power supply or display backlight may have failed and the unit should be sent for repair or replacement.
HMI panel fails to communicate with the S7 PLC
Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC MPI address configured in the WinCC flexible project matches the actual PLC address. Confirm the PLC is powered and in RUN or STOP mode.
Correct any address mismatches in the WinCC flexible project and re-download. Replace the communication cable if damaged. Ensure bus termination resistors are active only at the physical ends of the bus segment.
Panel continuously restarts or enters a boot loop
This may indicate a corrupted operating system or project file on the panel. Attempt to access the panel loader screen during startup by pressing the appropriate key combination as the panel powers on.
Use the Siemens ProSave utility to restore the panel operating system via a serial or MPI connection. After OS restoration, re-download the WinCC flexible project to the panel.
Function keys do not respond to presses
Check for physical damage to the membrane keypad. Verify in the WinCC flexible project that the function keys are correctly assigned to events or screen navigation actions.
If key assignments are correct and the keys remain unresponsive, the membrane keypad assembly may be worn or damaged. The keypad overlay or the complete panel front assembly may require replacement.
Project download fails or times out
Confirm the panel is set to transfer mode. Check the PC-to-panel connection cable and the selected communication interface in WinCC flexible transfer settings. Verify the correct MPI address or COM port is selected.
Restart the panel in transfer mode and retry the download. Replace the transfer cable if suspected faulty. Ensure no firewall or Windows driver issue is blocking the MPI adapter communication on the PC.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page



