• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7DB2 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7DB2 OP 77B

    € 2.070,40

    Reset
    Clear
    SKU: 6AV6355-1CA47-7DB2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7DB2 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a text-based display for process visualization and operator control. It is a member of the Micro Panel range, intended for straightforward monitoring and control tasks in automated systems.

    The OP 77B features a monochrome STN LCD display capable of showing multiple lines of text and numeric values, with a membrane keypad for operator input. It supports the MPI (Multi-Point Interface) and PROFIBUS DP communication protocols, enabling direct integration with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. The unit is configured using Siemens WinCC flexible software and offers a compact, panel-mount form factor with an IP65 protection rating on the front face, making it suitable for industrial environments.

    The OP 77B is widely used in manufacturing, packaging, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. Its compatibility with the SIMATIC S7 controller family makes it a natural fit for existing Siemens automation architectures. Typical installations include conveyor systems, pump stations, mixing equipment, and general-purpose machine control panels.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Lines 4 lines of text
    Communication Interface MPI, PROFIBUS DP
    Input Voltage 24 V DC
    Power Consumption Max. 4 W
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Configuration Software WinCC flexible 2005 or higher
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series SIMATIC HMI OP 77B

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP 77B and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the panel configuration in WinCC flexible.
    Event ID: 10001
    PLC is not responding or is in STOP mode. The operator panel has lost communication with the configured controller.
    Confirm the PLC is in RUN mode and powered. Check the communication cable and connector integrity. Verify baud rate and station address settings.
    Event ID: 20000
    Configuration download error. The project data could not be successfully transferred to the panel.
    Ensure the correct WinCC flexible version is used. Check the transfer cable connection and verify that the panel is in transfer mode before initiating download.
    Event ID: 40000
    Tag read error. The panel is unable to read a configured process tag from the PLC.
    Verify the PLC data block or memory address referenced by the tag exists and is accessible. Check for address conflicts in the PLC program.
    Event ID: 40001
    Tag write error. The panel is unable to write a value to a configured process tag in the PLC.
    Check that the target PLC memory area is not write-protected. Verify the tag address configuration in WinCC flexible matches the PLC data structure.
    Event ID: 50000
    System memory low. The panel's internal memory resources are running low, which may affect display performance.
    Reduce the number of active alarms or logged data entries. Consider simplifying the project configuration to reduce memory usage.
    Event ID: 60000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration to reduce the frequency of alarm events or increase acknowledgement intervals.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B?

    The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via the MPI interface or a dedicated PC/PPI cable.

    What is the supply voltage for the 6AV6355-1CA47-7DB2?

    The panel operates on a 24 V DC supply voltage. Ensure a stable, regulated 24 V DC power source is used to avoid display or communication issues.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for typical industrial panel installations.

    Can the OP 77B display graphics or only text?

    The OP 77B is primarily a text-based operator panel and is not designed for graphical visualization. It displays alphanumeric text, numeric values, and status information across its available display lines.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the supply is within the specified range and that the connector is firmly seated.

    Restore the correct 24 V DC supply. If voltage is present and the display remains blank, the internal power supply or LCD backlight may be faulty and the unit should be inspected or replaced.

    Panel shows communication error and cannot connect to PLC

    Inspect the MPI or PROFIBUS DP cable for damage, loose connectors, or missing bus termination resistors at the cable ends. Verify the station address and baud rate configured in WinCC flexible match the PLC settings.

    Replace or reseat the communication cable. Ensure bus termination is correctly applied at both ends of the network. Correct any address or baud rate mismatches in the panel project and PLC configuration.

    Project download fails or transfer does not complete

    Confirm the panel is set to transfer mode before initiating the download from WinCC flexible. Check that the correct communication port and transfer settings are selected in the software.

    Restart the panel in transfer mode and retry the download. If the issue persists, check the MPI cable integrity and ensure the WinCC flexible project is compatible with the OP 77B firmware version.

    Keypad buttons are unresponsive or intermittently fail

    Inspect the membrane keypad for physical damage, contamination, or wear. Test each key systematically within a diagnostic or test screen if available in the panel configuration.

    Clean the keypad surface with a dry cloth. If keys remain unresponsive, the membrane keypad assembly may be worn or damaged and requires replacement.

    Alarm messages are not displaying correctly or are missing

    Review the alarm configuration in WinCC flexible to verify that alarm tags are correctly mapped to PLC addresses. Check that the PLC program is setting the correct bit addresses associated with the configured alarms.

    Correct any tag address mismatches in the WinCC flexible project and re-download the configuration. Ensure the PLC program logic correctly triggers the alarm bits as intended.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart