• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7BB7 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7BB7 OP 77B

    € 2.995,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7BB7 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7BB7 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This unit is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward interface for monitoring and controlling industrial processes. As part of the SIMATIC HMI Basic Panels generation, it is engineered to integrate seamlessly with Siemens SIMATIC S7 controllers and other compatible automation systems.

    The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a backlit screen for visibility in varying ambient light conditions. It supports communication via MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, enabling direct connection to S7-200, S7-300, and S7-400 PLCs. The panel is configured using Siemens WinCC flexible software and offers function keys for direct operator input, along with a membrane keypad for reliable industrial use. It operates on a 24 V DC supply and carries an IP65 protection rating on the front face.

    The OP 77B is widely deployed in manufacturing, packaging, and process automation environments where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and keypad-based operation make it suitable for panel door mounting in control cabinets across industries such as automotive, food and beverage, and general machinery. The panel's compatibility with the broad SIMATIC S7 controller family makes it a practical choice for both new installations and retrofit projects.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 80 pixels
    Display Colors Monochrome (blue/white)
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 4 W
    Communication Interface MPI, PROFIBUS DP, RS-422/RS-485
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting (portrait or landscape)
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2008 or higher
    Series/Product Family SIMATIC HMI OP 77B

    Common Error Codes & System Events

    Event ID: 10000
    Connection to the PLC has been interrupted or could not be established.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify PLC address settings and communication parameters in WinCC flexible project.
    Event ID: 10001
    Communication timeout: no response received from the configured controller within the expected time.
    Verify the PLC is powered and running. Check bus address configuration on both the OP 77B and the PLC. Inspect cable integrity.
    Event ID: 20000
    Project download error: the configuration project could not be transferred to the panel.
    Ensure the correct transfer cable is used and the panel is in transfer mode. Verify WinCC flexible version compatibility and available panel memory.
    Event ID: 40000
    System memory low: available memory on the panel is insufficient for the loaded project.
    Reduce the project size by removing unused screens or tags. Perform a full panel reset and re-download the project.
    Event ID: 50000
    Backlight failure or backlight lifetime warning.
    If the display is still readable, note that backlight replacement requires panel servicing. Consider replacing the panel unit if backlight has failed completely.
    Event ID: 60000
    Panel operating system error or firmware mismatch detected.
    Update the panel firmware using ProSave or WinCC flexible to match the required OS version. Perform a factory reset if the panel fails to boot correctly.
    Event ID: 70000
    Tag update error: one or more process tags could not be read or written.
    Check PLC program to ensure the configured data addresses exist and are accessible. Verify tag data types match between the HMI project and the PLC.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7BB7)?

    The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports connection to S7-200 via RS-422/RS-485 (PPI protocol).

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via a PC/PPI or MPI cable, or through the PROFIBUS network.

    What is the supply voltage for the OP 77B?

    The panel operates on 24 V DC. Ensure the power supply is within the specified tolerance range to avoid operational issues.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel door mounting.

    Can the OP 77B be used as a replacement for older Siemens OP7 or OP17 panels?

    The OP 77B is designed as a functional successor to older SIMATIC HMI panels such as the OP7 and OP17. However, projects must be migrated or reconfigured in WinCC flexible, as direct project transfer from older tools like ProTool is not supported without migration.

    Troubleshooting

    Display remains blank after power is applied

    Measure 24 V DC at the power supply terminals on the rear of the panel. Check the internal fuse if accessible. Verify the power supply unit can deliver sufficient current.

    Ensure the 24 V DC supply is stable and within tolerance. Replace the power supply if voltage is absent. If voltage is correct but display remains blank, the backlight or internal power board may have failed and the panel should be sent for repair or replacement.

    Panel shows 'No connection to PLC' or communication error on startup

    Check the MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination is correctly applied at both ends of the network. Confirm the PLC address and baud rate settings match the HMI project configuration.

    Re-seat all communication connectors and replace any damaged cables. Correct the bus address and baud rate in the WinCC flexible project and re-download. Ensure only the two physical end nodes on the bus have termination resistors enabled.

    Panel is stuck in transfer mode and will not load the operating project

    The panel may have been left in transfer mode after a previous download attempt, or the project download was interrupted. The panel will remain in transfer mode until a valid project is received.

    Connect the programming PC with WinCC flexible and initiate a full project download to the panel. If the download fails repeatedly, perform a factory reset using ProSave and then re-download the OS and project.

    Function keys do not respond or produce incorrect actions

    Check the WinCC flexible project to verify that function key assignments are correctly configured for the active screen. Inspect the membrane keypad for physical damage or contamination beneath the keys.

    Correct the function key configuration in the WinCC flexible project and re-download. If keys are physically damaged or unresponsive due to membrane wear, the keypad membrane or the complete panel unit will need to be replaced.

    Panel reboots unexpectedly during operation

    Unexpected reboots are often caused by voltage dips on the 24 V DC supply line, excessive electrical noise, or an unstable project configuration causing a watchdog timeout.

    Install a regulated, adequately rated 24 V DC power supply with sufficient current capacity. Add surge protection on the supply line. Review the WinCC flexible project for any script or tag polling configurations that may cause system overload, and update panel firmware to the latest version.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart