• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7BB1 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7BB1 OP 77B

    € 1.287,43

    Reset
    Clear
    SKU: 6AV6355-1CA47-7BB1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7BB1 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a keypad-based interface for process visualization and control. It is part of the SIMATIC HMI Basic Panels generation and is manufactured by Siemens AG under the SIMATIC portfolio.

    The OP 77B features a monochrome STN LCD display with a resolution of 128 x 64 pixels and a backlit screen for clear readability in various lighting conditions. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs without an additional communication module. The panel supports configuration via Siemens WinCC flexible software and offers a membrane keypad with function keys for operator input, along with a compact and robust housing suited for panel mounting.

    The OP 77B is widely used in manufacturing, packaging, and process automation environments where a cost-effective, reliable operator interface is required at the machine level. Its compatibility with the SIMATIC S7 controller family makes it a practical choice for retrofitting or upgrading existing Siemens-based automation systems. The panel is suited for applications in the food and beverage, automotive, and general industrial machinery sectors where simple status display and parameter entry are the primary requirements.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 128 x 64 pixels
    Display Size 4 inches (diagonal)
    Input Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI / PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Mounting Panel mounting
    Configuration Software WinCC flexible 2008 or higher
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication timeout on MPI/PROFIBUS DP interface.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Check configured station address matches PLC settings.
    Event ID: 10001
    No connection to configured PLC at startup.
    Verify communication parameters (baud rate, station address) in WinCC flexible project match PLC configuration. Check physical wiring.
    Event ID: 20000
    Project download failed or project data corrupted.
    Re-download the project from WinCC flexible to the panel. Ensure compatible WinCC flexible version is used and USB/MPI transfer cable is functioning correctly.
    Event ID: 40000
    Internal device error or hardware fault detected.
    Perform a factory reset of the panel. If the error persists, the unit may require repair or replacement of internal components.
    Event ID: 50000
    Configured tag or variable address not found in PLC.
    Verify that all tag addresses configured in WinCC flexible exist in the connected PLC program. Update and re-download the project if addresses have changed.
    Event ID: 60000
    Backlight failure or display illumination fault.
    Check operating hours of backlight. If backlight has exceeded service life, the display unit or backlight assembly requires replacement.
    Event ID: 70000
    Power supply undervoltage detected.
    Measure 24 V DC supply at the panel power connector. Ensure supply voltage is within the specified 20.4 V DC to 28.8 V DC range. Check power supply unit output.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7BB1)?

    The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. It can also connect to S7-1200 and S7-1500 controllers with appropriate configuration.

    What software is used to configure and program the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via MPI cable or USB-to-MPI adapter.

    What is the supply voltage for the 6AV6355-1CA47-7BB1?

    The panel requires a 24 V DC supply voltage, with an acceptable operating range of approximately 20.4 V DC to 28.8 V DC.

    What is the front panel protection rating of the OP 77B?

    The front panel of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Can the OP 77B display alarm messages and process values?

    Yes, the OP 77B supports alarm logging, message display, and process value visualization through configured tags linked to the connected PLC, using the WinCC flexible project.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the supply is within the 20.4 V to 28.8 V DC range. Inspect the internal fuse if accessible.

    Restore correct supply voltage if out of range. If voltage is correct and display remains blank, the backlight or internal power supply board may have failed and the unit should be sent for repair or replacement.

    Panel shows 'No connection to PLC' or communication error at startup

    Verify MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network. Confirm the station address and baud rate in the WinCC flexible project match the PLC settings.

    Correct any wiring faults, adjust termination, and ensure communication parameters match. Re-download the project if configuration changes were made.

    Project download to panel fails or transfer is interrupted

    Check the USB-to-MPI or PC adapter cable for faults. Verify the WinCC flexible software version is compatible with the OP 77B firmware version. Ensure the panel is in transfer mode before initiating download.

    Replace the transfer cable if faulty. Update or match the WinCC flexible version to the panel firmware. Place the panel in transfer mode via the Start Center menu and retry the download.

    Keypad buttons are unresponsive or intermittently fail

    Inspect the membrane keypad surface for physical damage, contamination, or wear. Check for any debris lodged under the keypad overlay. Test each key systematically in a diagnostic or test screen if available.

    Clean the keypad surface with a dry cloth. If keys are physically damaged or the membrane has failed, the keypad membrane assembly requires replacement. Contact a qualified repair technician for internal membrane replacement.

    Display backlight is dim or flickering

    Check the operating hours of the panel and compare against the rated backlight service life. Inspect supply voltage stability, as voltage fluctuations can cause backlight flickering.

    If the backlight has exceeded its rated service life or is physically degraded, the display module or backlight assembly must be replaced. Stabilize the 24 V DC supply if voltage fluctuations are identified as the cause.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart