Siemens 6AV6355-1CA47-7BB3 OP 77B
€ 1.995,00
The Siemens 6AV6355-1CA47-7BB3 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels series. It is a compact, key-operated operator panel designed for straightforward machine-level human-machine interface tasks, offering a monochrome display and a membrane keypad for operator input. This unit is part of Siemens' established line of entry-level HMI devices intended for integration into standard industrial control cabinets.
The OP 77B features a 4-line STN monochrome LCD display capable of showing text and simple graphics, paired with a membrane keypad that includes function keys, system keys, and numeric input keys. It communicates via MPI and PROFIBUS DP interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel is configured using WinCC flexible software and supports recipe management, alarm logging, and trend display functions within its onboard memory.
The OP 77B is widely deployed in manufacturing, packaging, and process automation environments where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine fronts with limited space. Industries such as food and beverage, automotive assembly, and general factory automation commonly use this panel for operator guidance, parameter entry, and alarm acknowledgment tasks.
Technical Specifications
| Display Type | STN monochrome LCD |
|---|---|
| Display Lines | 4 lines of text |
| Input Method | Membrane keypad |
| Communication Interface | MPI, PROFIBUS DP |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Configuration Software | WinCC flexible |
| Supply Voltage | 24 V DC |
| Power Consumption | Max. 4.5 W |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 1000
- Connection to PLC lost or communication timeout on MPI/PROFIBUS DP interface.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Check configured station address matches the PLC. - Event ID: 1003
- No connection to configured PLC partner; connection request rejected.
Verify the PLC address and network parameters in the WinCC flexible project match the physical configuration. Restart both the panel and PLC. - Event ID: 10000
- System startup error; project data could not be loaded from internal memory.
Re-transfer the WinCC flexible project to the panel. If the error persists, perform a factory reset and re-download the project. - Event ID: 10001
- Project transfer active; the panel is in transfer mode awaiting a new project download.
Transfer the project from the WinCC flexible engineering station. If transfer mode was entered unintentionally, restart the panel. - Event ID: 20000
- Internal memory error detected during self-test at startup.
Perform a factory reset of the panel. If the fault recurs, the internal memory or CPU board may require replacement. - Event ID: 40000
- Alarm buffer overflow; the number of pending alarms exceeds the buffer capacity.
Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to reduce simultaneous alarm generation. - Event ID: 50000
- Recipe data error; recipe record could not be read or written correctly.
Check recipe configuration in WinCC flexible. Re-transfer the project and verify that recipe memory allocation is within the panel's capacity.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7BB3)?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with SIMATIC S7-1200 in some configurations using appropriate drivers in WinCC flexible.
What software is used to configure and program the OP 77B?
The OP 77B is configured using Siemens WinCC flexible software. Projects are transferred to the panel via the MPI interface or a PC adapter cable.
What is the supply voltage for the 6AV6355-1CA47-7BB3?
The panel requires a 24 V DC supply voltage for operation.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for cabinet-front mounting in industrial environments.
Can the OP 77B display graphics or only text?
The OP 77B's monochrome STN LCD is primarily a text-based display capable of showing 4 lines of characters. Simple bar graphs and basic graphical elements are supported, but it is not designed for complex graphical visualization.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the specified tolerance. Inspect the panel for any visible damage to the connector or board.
Ensure the 24 V DC supply is stable and correctly wired. If the supply is correct and the display remains blank, the internal power supply or LCD backlight may have failed and the unit should be sent for repair or replacement.
Panel shows 'No connection to PLC' or communication error on startup
Verify MPI or PROFIBUS DP cable integrity and correct termination at both ends of the network. Check that the PLC station address configured in the WinCC flexible project matches the physical PLC address setting.
Replace or reseat the communication cable. Correct any address mismatches in the project and re-transfer to the panel. Ensure termination resistors are only active at the two physical ends of the bus.
Project transfer from WinCC flexible fails or times out
Check the PC adapter cable connection between the engineering PC and the panel's MPI port. Verify that the panel is in transfer mode and that the correct COM port and transfer speed are selected in WinCC flexible.
Restart the panel in transfer mode by holding the appropriate key combination during boot. Confirm the PC adapter driver is correctly installed and the baud rate matches the project settings, then retry the transfer.
Operator keys are unresponsive or register incorrect inputs
Inspect the membrane keypad surface for physical damage, contamination, or deformation. Test individual keys systematically using the panel's built-in key test function if available in the service menu.
Clean the keypad surface with a dry cloth. If keys remain unresponsive after cleaning, the membrane keypad assembly is likely worn or damaged and should be replaced.
Panel repeatedly restarts or enters an error loop after project download
Check the WinCC flexible project for configuration errors such as invalid PLC addresses, unsupported tag types, or memory allocation exceeding the panel's capacity.
Review and correct the project configuration in WinCC flexible, reduce the number of tags or alarms if memory limits are exceeded, and re-transfer the corrected project to the panel.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page