Siemens 6AV6355-1AA47-7EQ0 OP 77A
The Siemens 6AV6355-1AA47-7EQ0 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling automated processes. This unit is part of the SIMATIC HMI Basic Panels generation and is intended for use with Siemens SIMATIC S7 controllers.
The OP 77A features a monochrome LCD display with a resolution of 160 x 80 pixels, capable of displaying text and simple graphics for process visualization. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers a membrane keypad with function keys for operator input. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The OP 77A is widely used in manufacturing, packaging, and machine tool industries where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and simple keypad-based operation make it suitable for applications where touchscreen functionality is not required and where panel space is limited. The unit is commonly found on conveyor systems, injection molding machines, and general-purpose industrial machinery.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Input Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Configuration Software | WinCC flexible |
| Input Method | Membrane keypad with function keys |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series | SIMATIC HMI OP 77A |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration in WinCC flexible. - Event ID: 10001
- Connection to the PLC was interrupted during operation.
Inspect communication cables for damage or loose connectors. Verify PLC is powered and running. Re-establish connection and check network topology. - Event ID: 20000
- Project download error. The configuration project could not be transferred to the panel.
Check the PC-to-panel transfer cable and connection. Ensure WinCC flexible project is compiled without errors before downloading. - Event ID: 40000
- System memory low. The panel is running low on available memory resources.
Reduce the number of active alarms or logged data entries. Simplify the project configuration if possible and re-download the project. - Event ID: 50000
- Tag read/write error. A configured tag could not be read from or written to the PLC.
Verify the PLC data block addresses referenced in the WinCC flexible project are correct and accessible. Check PLC program for address conflicts. - Event ID: 60000
- Illegal system state detected. The panel has encountered an internal error or unexpected operating condition.
Perform a panel restart. If the error persists, reload the project via WinCC flexible. Contact Siemens technical support if the issue continues. - Event ID: 70000
- Configuration error. The loaded project contains settings incompatible with the current panel firmware version.
Update the panel firmware to match the WinCC flexible project version, or recompile and re-download the project using a compatible software version.
Frequently Asked Questions
Which PLCs are compatible with the OP 77A?
The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.
What software is used to configure the OP 77A?
The OP 77A is configured using Siemens WinCC flexible software. The project is then downloaded to the panel via a PC adapter or direct cable connection.
What is the supply voltage for the 6AV6355-1AA47-7EQ0?
The panel operates on a 24 V DC supply voltage.
What is the front panel protection rating of the OP 77A?
The front face of the OP 77A is rated IP65, providing protection against dust ingress and low-pressure water jets.
Does the OP 77A support touchscreen input?
No, the OP 77A uses a membrane keypad with dedicated function keys for operator input and does not support touchscreen operation.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify polarity is correct and voltage is within the specified range.
Ensure the power supply is delivering stable 24 V DC. Replace the power supply if voltage is absent or out of tolerance. Check internal fuse if accessible.
Panel displays communication error and cannot connect to PLC
Verify MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Check that the bus termination resistors are correctly placed at both ends of the network.
Correct any wiring faults, replace damaged cables, and ensure bus termination is active only at the physical ends of the network. Confirm that the PLC address and baud rate in the WinCC flexible project match the actual PLC settings.
Project download fails or transfer is interrupted
Check the PC-to-panel transfer cable for damage. Ensure the panel is in transfer mode before initiating the download from WinCC flexible.
Replace the transfer cable if faulty. Set the panel to transfer mode via the panel's start menu, then retry the download. Ensure the WinCC flexible project compiles without errors prior to transfer.
Function keys do not respond to operator input
Inspect the membrane keypad for physical damage, contamination, or deformation. Test each key individually to identify whether the fault is isolated to specific keys or affects all keys.
Clean the keypad surface if contaminated. If individual keys are unresponsive due to membrane damage, the keypad assembly or the entire panel front unit may require replacement.
Panel repeatedly restarts or freezes during operation
Check the 24 V DC supply for voltage dips or instability under load. Review the WinCC flexible project for configuration errors or excessive tag polling rates.
Stabilize the power supply and ensure adequate current capacity. Reduce tag update cycles in the project configuration if necessary. Reload the project to the panel and update firmware if the issue persists.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page