
Siemens 6AV6355-1AA47-7EA3 OP 77A
The Siemens 6AV6355-1AA47-7EA3 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated operator panel designed for machine-level human-machine interface applications, providing a straightforward interface for process monitoring and control. This unit belongs to the SIMATIC HMI Basic Panels generation and is intended for use with Siemens SIMATIC S7 controllers.
The OP 77A features a monochrome LCD display with a resolution of 160 x 80 pixels, providing clear text and simple graphic visualization. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with S7-200, S7-300, and S7-400 PLCs. The panel includes function keys and navigation keys for operator input, and is configured using WinCC flexible compact engineering software. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The OP 77A is commonly deployed in manufacturing, packaging, and process automation environments where a cost-effective, robust operator interface is required at the machine level. Its compact form factor makes it suitable for installation in control cabinet doors and machine panels with limited space. The panel is well-suited for applications requiring basic setpoint entry, status display, and alarm acknowledgment without the need for complex graphical visualization.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Engineering Software | WinCC flexible Compact |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC HMI OP 77A |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 1003
- Communication error between the operator panel and the connected PLC. The panel cannot establish or maintain a connection.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the panel configuration in WinCC flexible. - Event ID: 1004
- Connection to the configured PLC has been lost during operation.
Inspect communication cables for damage or loose connectors. Verify PLC is powered and running. Check bus termination and cable shielding. - Event ID: 10000
- System startup error. The panel failed to complete its boot sequence correctly.
Perform a panel reset. If the issue persists, reload the project via WinCC flexible or restore factory settings using the panel's loader menu. - Event ID: 10001
- Project download failed or project data is corrupt.
Re-download the project from WinCC flexible to the panel. Ensure the engineering software version is compatible with the panel firmware version. - Event ID: 20000
- Internal device error detected during self-test.
Cycle power to the panel. If the fault persists, the panel may require repair or replacement of internal components. - Event ID: 40000
- Alarm buffer overflow. The number of pending alarms exceeds the panel's buffer capacity.
Acknowledge and clear existing alarms. Review the alarm configuration in WinCC flexible to reduce the number of simultaneously active alarms. - Event ID: 1703
- Tag read/write error. The panel cannot read from or write to a configured PLC tag.
Verify the PLC tag addresses configured in WinCC flexible match the actual PLC data block or memory addresses. Check PLC program is running.
Frequently Asked Questions
Which PLCs are compatible with the OP 77A?
The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.
What software is used to configure the OP 77A?
The OP 77A is configured using Siemens WinCC flexible Compact engineering software. Projects are downloaded to the panel via a PC/PPI cable or MPI connection.
What is the supply voltage for the 6AV6355-1AA47-7EA3?
The panel operates on a 24 V DC supply voltage.
What is the front panel protection rating of the OP 77A?
The front face of the OP 77A is rated IP65, providing protection against dust and low-pressure water jets, making it suitable for industrial panel-door mounting.
Can the OP 77A display graphical images?
The OP 77A has a monochrome LCD display with a resolution of 160 x 80 pixels, which supports basic text and simple graphics but is not intended for complex graphical visualization.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply terminals. Measure voltage directly at the panel connector to rule out wiring issues. Inspect the internal fuse if accessible.
Ensure the 24 V DC supply is within tolerance. Replace any blown fuse. If the supply is correct and the display remains blank, the panel backlight or internal power board may require repair.
Panel shows communication error and cannot connect to PLC
Verify the MPI or PROFIBUS DP address configured in WinCC flexible matches the PLC settings. Check cable continuity and bus termination at both ends of the network.
Correct any address mismatches in the project configuration. Replace damaged cables and ensure proper bus termination resistors are installed at both ends of the MPI or PROFIBUS segment.
Project download fails from WinCC flexible
Confirm the communication cable between the PC and panel is correctly connected and the correct COM port or USB adapter driver is installed. Check that the WinCC flexible version supports the OP 77A firmware version.
Update the PC/PPI or MPI adapter drivers. Ensure WinCC flexible is updated to a compatible version. Try resetting the panel to factory defaults via the loader menu before re-downloading the project.
Panel repeatedly reboots or freezes during operation
Check the 24 V DC supply for voltage dips or instability under load. Inspect the environment for excessive temperature or vibration. Review the panel's event log for recorded system events.
Stabilize the power supply and ensure it is adequately rated. Verify the operating temperature is within 0 °C to +50 °C. If the issue persists, reload the project firmware or arrange panel repair.
Function keys do not respond to operator input
Check whether the panel is in transfer mode or loader mode, which disables normal operation. Verify the project configuration assigns actions to the function keys correctly in WinCC flexible.
Exit transfer or loader mode by completing or cancelling the transfer operation. Re-download the project with correct function key assignments. If keys are physically damaged, the panel keypad membrane may need replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page



