• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7CF2 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7CF2 OP 77A

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7CF2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7CF2 is an operator panel belonging to the SIMATIC HMI OP 77A series, designed for human-machine interface applications in industrial automation environments. This compact panel provides a keypad-based interface for machine monitoring and control, and is part of Siemens' SIMATIC HMI product line. It is intended for use with SIMATIC S7 PLCs and other compatible Siemens controllers.

    The OP 77A features a monochrome LCD display and a membrane keypad with function keys, system keys, and numeric entry capability. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration into Siemens automation networks. The unit operates on a 24 V DC supply and supports configuration through Siemens WinCC flexible engineering software. Its compact and robust construction is suited for panel-mount installation in industrial cabinets.

    The OP 77A is commonly deployed in manufacturing, machine building, and process automation applications where a cost-effective, reliable operator interface is required. It is well suited for machinery requiring straightforward parameter entry, status display, and alarm management without the need for a full graphical touchscreen panel. Typical installations include packaging machines, conveyor systems, and general-purpose industrial machinery.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input Voltage 24 V DC
    Voltage Tolerance 19.2 V DC to 28.8 V DC
    Communication Interface MPI, PROFIBUS DP
    Configuration Software WinCC flexible 2005 or higher
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mount
    Certifications CE, UL, cULus
    Series SIMATIC HMI OP 77A

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication timeout on MPI/PROFIBUS DP interface.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Check configured station address matches the PLC.
    Event ID: 10001
    Connection to configured PLC could not be established at startup.
    Verify communication parameters (baud rate, station address) in WinCC flexible project match the PLC configuration. Check physical cable integrity.
    Event ID: 40000
    No project loaded on the operator panel.
    Transfer a valid WinCC flexible project to the panel using the configured download interface. Ensure the project is compiled without errors before transfer.
    Event ID: 40001
    Project transfer interrupted or incomplete.
    Retry the project download from the WinCC flexible engineering station. Check the transfer cable and ensure the panel is in transfer mode.
    Event ID: 20000
    Tag read error — the panel cannot read a configured PLC tag.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory area. Check PLC program for correct data structure.
    Event ID: 20001
    Tag write error — the panel cannot write a value to the configured PLC tag.
    Check that the target PLC memory area is not write-protected. Verify tag address and data type configuration in the WinCC flexible project.
    Event ID: 70010
    Internal device error or firmware fault detected.
    Perform a power cycle of the panel. If the fault persists, perform a factory reset and re-transfer the project. Contact Siemens technical support if the issue continues.

    Frequently Asked Questions

    What communication interfaces does the OP 77A support?

    The OP 77A supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs.

    What software is required to configure the 6AV6355-1AA47-7CF2?

    The panel is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via the MPI or PROFIBUS DP interface.

    What is the supply voltage for this operator panel?

    The OP 77A requires a 24 V DC supply voltage, with an acceptable range of 19.2 V DC to 28.8 V DC.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A is rated IP65, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel-mount installations.

    Can the OP 77A be used with S7-1200 or S7-1500 PLCs?

    The OP 77A is primarily designed for use with S7-200, S7-300, and S7-400 PLCs via MPI and PROFIBUS DP. Compatibility with S7-1200 and S7-1500 is limited and should be verified against the specific firmware and WinCC flexible version in use.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the voltage is within the 19.2 V DC to 28.8 V DC range. Inspect the supply cable and connector for damage.

    Correct the supply voltage if out of range. Replace the power supply cable or connector if damaged. If the display remains blank with correct voltage, the internal power supply or display unit may require repair or replacement.

    Panel displays 'No project' or starts in transfer mode unexpectedly

    Check whether a valid WinCC flexible project has been successfully transferred to the panel. A missing or corrupted project will cause the panel to display a transfer prompt on startup.

    Compile and re-transfer the WinCC flexible project to the panel. Ensure the transfer completes without errors. If the panel repeatedly loses its project, check the internal memory for faults.

    Communication error displayed — cannot connect to PLC

    Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check bus termination at both ends of the network. Confirm the station address and baud rate configured in the project match the PLC settings.

    Correct any wiring or termination issues. Adjust the communication parameters in the WinCC flexible project to match the PLC configuration, then re-transfer the project and power cycle both devices.

    Function keys do not respond or produce incorrect actions

    Check the WinCC flexible project configuration for the function key assignments. Verify that the correct screen is active and that the key assignments are not overridden by a global function key template.

    Review and correct the function key configuration in WinCC flexible. Re-transfer the updated project to the panel. If keys are physically unresponsive, the membrane keypad may require replacement.

    Panel freezes or becomes unresponsive during operation

    Check for communication overload on the MPI/PROFIBUS DP network. Review the WinCC flexible project for excessive tag update rates or script errors that may cause the panel CPU to overload.

    Reduce tag update rates in the WinCC flexible project where possible. Correct any script errors. Perform a power cycle to restore normal operation. If freezing persists, perform a firmware update or factory reset and re-transfer the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart