Siemens 6AV6355-1AA47-7CE3 OP 77A
€ 3.495,00
The Siemens 6AV6355-1AA47-7CE3 is an operator panel belonging to the SIMATIC HMI OP 77A series, designed for human-machine interface applications in industrial automation environments. This unit is part of the Siemens SIMATIC HMI product line and provides a compact, panel-mounted interface for machine-level operator control and monitoring. The OP 77A series is engineered for integration with Siemens SIMATIC S7 PLCs and other compatible controllers.
The OP 77A features a monochrome LCD display with a resolution of 160 x 80 pixels and a membrane keypad for operator input, providing a robust and reliable interface without touchscreen complexity. It supports the MPI and PROFIBUS DP communication protocols, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs. The device operates on a 24 V DC supply and is configured using Siemens WinCC flexible software, supporting text-based process visualization, alarm management, and recipe handling within its onboard memory.
The OP 77A is commonly deployed in manufacturing, packaging, and process automation applications where a cost-effective, durable operator interface is required at the machine level. Its compact form factor and keypad-based operation make it well-suited for environments where touchscreen panels are impractical due to contamination or gloved-hand operation. Industries such as food and beverage, automotive assembly, and general machine building frequently utilize this panel for local operator control tasks.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Input Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Configuration Software | WinCC flexible 2005 or higher |
| Mounting | Panel mounting |
| Input Method | Membrane keypad |
| Series | SIMATIC HMI OP 77A |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Connection to the PLC could not be established or was interrupted during operation.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI configuration in WinCC flexible. - Event ID: 10001
- Communication timeout: no response received from the configured controller within the expected time window.
Check network cabling and bus termination. Verify the PLC is in RUN mode and the configured station address is correct. - Event ID: 20000
- Tag read error: the HMI was unable to read a configured process tag from the controller.
Verify the tag address in WinCC flexible matches the actual PLC memory address. Check PLC program for address conflicts. - Event ID: 20001
- Tag write error: the HMI was unable to write a value to the configured controller tag.
Check that the target PLC memory area is not write-protected. Verify the data type of the tag matches the PLC variable. - Event ID: 40000
- Project download error: the configuration project could not be transferred to the HMI panel.
Verify the PC-to-HMI communication cable is correctly connected. Ensure WinCC flexible version is compatible with the OP 77A firmware version. - Event ID: 50000
- Internal device error: a hardware or firmware fault has been detected on the panel.
Perform a factory reset of the device. If the fault persists, the panel may require repair or replacement of internal components. - Event ID: 60000
- Alarm buffer overflow: the number of pending alarms has exceeded the panel's alarm buffer capacity.
Acknowledge and clear existing alarms. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers.
Frequently Asked Questions
Which PLCs are compatible with the OP 77A (6AV6355-1AA47-7CE3)?
The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-200 via the PPI protocol depending on firmware configuration.
What software is required to configure the OP 77A?
The OP 77A is configured using Siemens WinCC flexible 2005 or a later compatible version. The project is downloaded to the panel via a PC adapter cable connected to the MPI interface.
What is the supply voltage for the 6AV6355-1AA47-7CE3?
The panel requires a 24 V DC power supply. Ensure the supply is within the permitted tolerance range as specified in the device documentation.
Does the OP 77A support recipe management?
Yes, the OP 77A supports basic recipe management functionality, allowing operators to store and transfer parameter sets between the HMI and the connected PLC.
What is the IP protection rating of the OP 77A?
The front panel of the OP 77A is rated IP65, providing protection against dust and low-pressure water jets. The rear of the unit is rated IP20.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector. Check that the supply is within the specified tolerance and that polarity is correct.
Correct any wiring errors or supply voltage issues. If the supply is confirmed good and the display remains blank, the internal power supply or display backlight may require replacement.
HMI cannot establish communication with the PLC
Verify the MPI or PROFIBUS DP cable is correctly connected and that bus termination resistors are in place at both ends of the network. Check that the station address configured in WinCC flexible matches the PLC address.
Correct cable connections and termination. Adjust station addresses in the WinCC flexible project and re-download the configuration to the panel.
Panel displays 'No project' or starts in transfer mode unexpectedly
The onboard flash memory may not contain a valid project, or the panel has been reset to factory defaults. Check whether a project has been successfully downloaded previously.
Connect a PC with WinCC flexible and download the correct project to the panel using the PC adapter cable via the MPI interface.
Keypad buttons are unresponsive or intermittently fail
Inspect the membrane keypad for physical damage, contamination, or deformation. Check the internal ribbon cable connection between the keypad and the main PCB.
Clean the keypad surface if contaminated. If the ribbon cable is damaged or the membrane keypad is worn, replace the keypad assembly.
Alarms are not displayed or acknowledged correctly
Review the alarm configuration in WinCC flexible to confirm alarm triggers, bit addresses, and acknowledgement settings are correctly defined. Check the PLC program to verify alarm bits are being set as expected.
Correct any misconfigured alarm addresses or acknowledgement modes in the WinCC flexible project and re-download to the panel.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page