• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7CE2 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7CE2 OP 77A

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7CE2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7CE2 is an operator panel belonging to the SIMATIC HMI OP 77A series, designed for human-machine interface applications in industrial automation environments. This compact panel provides a key-operated interface for process visualization and control, and is part of Siemens' SIMATIC HMI product line. It is intended for use with Siemens SIMATIC S7 and other compatible controllers via standard communication interfaces.

    The OP 77A features a monochrome LCD display with a resolution suitable for text and simple graphic visualization, along with a membrane keypad for operator input. It supports MPI and PROFIBUS DP communication protocols, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and supports alarm management, recipe handling, and trend display functions. It operates on a 24 V DC supply and is built to withstand typical industrial environmental conditions.

    The OP 77A is commonly deployed in machine-level control panels across manufacturing, process automation, and packaging industries. Its compact form factor and keypad-based operation make it well suited for applications where a small footprint and robust input method are preferred over touchscreen interfaces. It is frequently used in machinery where operators need to monitor process values, acknowledge alarms, and adjust setpoints directly at the machine.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 inches
    Display Colors Monochrome (STN)
    Input Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Configuration Software WinCC flexible
    Series SIMATIC HMI OP 77A
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Restart both the panel and the PLC if necessary.
    Event ID: 10001
    No connection to the PLC. The HMI panel cannot reach the configured controller on the network.
    Verify the communication cable is properly connected and undamaged. Confirm the PLC is powered and running. Check that the station address and baud rate in the HMI project match the PLC settings.
    Event ID: 20000
    Tag read error. The HMI panel was unable to read a configured tag from the PLC.
    Verify the tag address in the WinCC flexible project matches the actual data block or memory area in the PLC program. Check that the PLC program is running and the relevant data areas are accessible.
    Event ID: 20001
    Tag write error. The HMI panel was unable to write a value to a configured tag in the PLC.
    Check that the target memory area in the PLC is not write-protected. Verify the tag address configuration in WinCC flexible. Ensure the PLC is in RUN mode and accepting write requests.
    Event ID: 40000
    Project download error. A fault occurred during transfer of the HMI project from the engineering PC to the panel.
    Check the transfer cable connection between the PC and the panel. Ensure the panel is in transfer mode. Verify that the WinCC flexible project is compatible with the firmware version on the panel.
    Event ID: 50000
    System memory low. The panel's available memory for runtime operation is insufficient.
    Reduce the number of active alarms, recipes, or trend data stored on the device. Optimize the project in WinCC flexible to reduce memory usage and re-download the project.
    Event ID: 60000
    Firmware version mismatch. The firmware on the panel is not compatible with the downloaded project.
    Update the panel firmware to the version required by the WinCC flexible project, or re-engineer the project targeting the firmware version currently installed on the panel.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A (6AV6355-1AA47-7CE2)?

    The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-1200 and certain third-party controllers depending on the protocol configuration.

    What software is used to configure and program the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible software. The project is then transferred to the panel via a PC adapter cable or PROFIBUS connection.

    What is the supply voltage for the 6AV6355-1AA47-7CE2?

    The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI operator panels.

    What is the front panel protection rating of the OP 77A?

    The OP 77A provides IP65 protection at the front panel when correctly installed in a control cabinet cutout, making it suitable for environments with dust and water spray.

    Can the OP 77A be used as a replacement for older SIMATIC OP panels?

    Yes, the OP 77A is designed as a successor to earlier SIMATIC operator panels such as the OP 7 and OP 17, and can often be used as a direct replacement with appropriate project adaptation in WinCC flexible.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel's power connector using a multimeter. Verify that the supply is within the specified range and that the connector is properly seated.

    Ensure the 24 V DC supply is stable and correctly wired. If the supply is confirmed good and the display remains blank, the internal power supply or display backlight may have failed and the unit should be sent for repair or replacement.

    HMI panel shows 'No connection to PLC' message at runtime

    Verify the MPI or PROFIBUS DP cable is connected to both the panel and the PLC. Check the bus termination at both ends of the cable. Confirm the PLC station address matches the address configured in the WinCC flexible project.

    Replace or reseat the communication cable. Correct any address mismatches in the project and re-download. Ensure bus terminators are installed only at the physical ends of the network segment.

    Project transfer from PC to panel fails or times out

    Check that the panel is set to transfer mode (accessible via the panel's start center or loader menu). Verify the PC adapter cable is functioning and the correct COM port or USB adapter is selected in WinCC flexible transfer settings.

    Restart the panel in transfer mode and retry the download. Try a different PC adapter cable if available. Ensure the WinCC flexible project version is compatible with the panel firmware version.

    Operator keys are unresponsive or intermittently fail

    Inspect the membrane keypad for physical damage, contamination, or wear. Check whether the issue is limited to specific keys or affects all keys, which helps distinguish between a localized keypad fault and a controller board issue.

    Clean the keypad surface with a dry cloth. If specific keys have failed due to wear, the membrane keypad assembly may need to be replaced. If all keys are unresponsive, inspect the internal ribbon cable connection between the keypad and the main board.

    Alarm messages are not displayed or acknowledged correctly

    Check the alarm configuration in the WinCC flexible project to ensure alarm tags are correctly mapped to PLC addresses. Verify that the PLC program is setting and resetting the alarm bits as expected.

    Correct any tag address mismatches in the alarm configuration and re-download the project. If alarms cannot be acknowledged, check that the acknowledgment bit address in the PLC program matches the configuration in WinCC flexible.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart