• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AD34-0MF6 OP 177B
    Awaiting product image

    Siemens 6AV6344-2AD34-0MF6 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6344-2AD34-0MF6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AD34-0MF6 is an operator panel belonging to the SIMATIC HMI OP 177B series, designed for machine-level human-machine interface applications. This unit is part of Siemens' SIMATIC HMI product line and provides a compact, panel-mounted interface for process visualization and control. The OP 177B offers a combination of touch and key-based operation, making it suitable for demanding industrial environments.

    The 6AV6344-2AD34-0MF6 features a 5.7-inch STN display with 256-color support and a resolution of 320 x 240 pixels (QVGA). It supports communication via PROFIBUS DP and MPI interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. The panel includes 14 function keys with LED indicators, a numeric keypad, and is configured using WinCC flexible engineering software. Onboard memory supports project storage and recipe management.

    The OP 177B is widely deployed in manufacturing, process automation, and machine tool industries where a reliable, mid-range operator interface is required. Its compact form factor and dual communication capability make it suitable for retrofitting existing PROFIBUS-based installations as well as new machine builds. The panel is commonly found on packaging machinery, conveyor systems, and general-purpose industrial machines requiring local operator control and status visualization.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Type STN color LCD
    Display Colors 256 colors
    Touch Technology Touch screen with membrane keypad
    Function Keys 14 function keys with LEDs
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 8 W
    Communication Interface PROFIBUS DP, MPI
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible 2005 or higher
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The configured connection cannot be established.
    Check PROFIBUS/MPI cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify bus termination at both ends of the PROFIBUS segment.
    Event ID: 20000
    Project download error. Transfer of the project from the engineering PC to the HMI panel failed.
    Verify the transfer cable is correctly connected. Ensure the panel is in Transfer mode before initiating download. Check that the WinCC flexible project version is compatible with the panel firmware.
    Event ID: 40000
    System memory low. Available memory on the HMI device is insufficient for the current project.
    Reduce the project size by removing unused screens, graphics, or recipes. Perform a memory cleanup and re-download the project.
    Event ID: 50000
    Firmware update error. The firmware update process was interrupted or failed.
    Restart the firmware update procedure using the correct firmware version for the OP 177B. Ensure stable power supply during the update process.
    Event ID: 60000
    Internal device error. A hardware fault has been detected within the HMI panel.
    Perform a power cycle. If the error persists, note the exact event ID sub-code and contact Siemens technical support or arrange for unit repair and inspection.
    Event ID: 70000
    Tag read/write error. The HMI was unable to read from or write to a configured PLC tag.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6344-2AD34-0MF6)?

    The OP 177B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-1200 and S7-1500 PLCs in some configurations using appropriate drivers in WinCC flexible.

    What engineering software is required to program this HMI panel?

    The OP 177B is configured using Siemens WinCC flexible 2005 or a later version. The project is transferred to the panel via a PC adapter cable connected to the MPI/PROFIBUS port.

    What is the supply voltage for the 6AV6344-2AD34-0MF6?

    The panel operates on 24 V DC. The supply must be within the specified tolerance range, typically 19.2 V DC to 28.8 V DC.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Can the OP 177B display be used as a touch-only interface?

    The OP 177B combines a resistive touch screen with physical function keys and a numeric keypad. Both input methods are available simultaneously and can be used depending on the application design.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the supply is within the 19.2 V to 28.8 V DC range. Inspect the internal fuse if accessible.

    Restore correct supply voltage. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight may have failed and the unit should be sent for repair.

    HMI panel shows 'No connection to PLC' or communication error on startup

    Verify the PROFIBUS or MPI cable is correctly seated at both the HMI and PLC ends. Check that bus termination resistors are active at both ends of the segment. Confirm the PLC station address in the HMI project matches the physical PLC setting.

    Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged cables or connectors. Ensure only the two physical endpoints of the PROFIBUS segment have termination enabled.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. Attempt a touchscreen recalibration from the panel's system settings menu. Verify that the touch controller is not reporting errors in the system event log.

    Clean the touch surface with a soft, dry cloth. Perform a recalibration procedure. If inaccuracy persists after recalibration, the resistive touch overlay may be worn or damaged and requires replacement.

    Project download fails or transfer is not initiated

    Confirm the panel is set to Transfer mode (accessible via the Start Center or by holding the appropriate key combination during boot). Check the PC adapter cable connection and driver installation on the engineering PC.

    Switch the panel to Transfer mode before starting the download in WinCC flexible. Reinstall the PC adapter USB driver if the COM port is not recognized. Ensure the correct interface (MPI/PROFIBUS) and baud rate are selected in the transfer settings.

    Function key LEDs do not illuminate

    Check the WinCC flexible project configuration to confirm LED output tags are correctly mapped to PLC bits. Verify the PLC program is writing the expected values to the mapped tags.

    Correct the tag mapping in the WinCC flexible project and re-download. If LEDs fail to illuminate despite correct configuration and confirmed PLC output, the keypad membrane assembly may be faulty and require replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart