• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6343-0AA04-0MA6 OP 177B
    Awaiting product image

    Siemens 6AV6343-0AA04-0MA6 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6343-0AA04-0MA6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6343-0AA04-0MA6 is an OP 177B operator panel belonging to the SIMATIC HMI family of human-machine interface devices. This unit provides a monochrome graphical display and is designed for machine-level visualization and operator control tasks. It is part of the Comfort and Mobile Panel generation predecessor line, offering reliable panel-based HMI functionality for industrial environments.

    The OP 177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and supports both touch and key-based operation through its integrated membrane keypad. It communicates via MPI, PROFIBUS DP, and Ethernet interfaces, enabling flexible integration into Siemens S7-300 and S7-400 PLC environments. The panel is configured using WinCC flexible 2008 engineering software and includes 512 KB user memory for project data, with an operating temperature range of 0 to 50 degrees Celsius.

    The OP 177B is widely deployed in manufacturing, automotive, food and beverage, and process industries where robust panel-based operator interfaces are required at the machine level. Its combination of keypad and touch input makes it suitable for environments where gloved operation or harsh conditions demand physical key actuation. The compact form factor and broad communication support make it a versatile choice for retrofitting and new machine installations alike.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome
    Display Resolution 320 x 240 pixels
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 12 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (RJ45)
    User Memory 512 KB
    Operating Temperature 0 to 50 °C
    Storage Temperature -20 to 60 °C
    Relative Humidity 10 to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP 177B
    Engineering Software WinCC flexible 2008

    Common Error Codes and System Events

    Event ID: 10000
    Configuration error detected during startup; project data may be corrupted or incompatible with the panel firmware version.
    Re-transfer the project using WinCC flexible 2008. Ensure the firmware version on the panel matches the project configuration.
    Event ID: 10001
    No project found on the panel; the device has started without a valid user project loaded.
    Transfer a valid project to the panel via Ethernet or MPI/PROFIBUS using WinCC flexible 2008 transfer function.
    Event ID: 20000
    Communication error on MPI/PROFIBUS DP interface; the panel cannot establish a connection to the configured PLC.
    Check MPI/PROFIBUS cable connections, verify bus address settings, and confirm the PLC is powered and in RUN mode.
    Event ID: 20001
    Ethernet communication timeout; the panel has lost connection to the PLC or network device configured via TCP/IP.
    Verify Ethernet cable integrity, check IP address configuration on both panel and PLC, and confirm network switch operation.
    Event ID: 40000
    Internal device error; a hardware fault has been detected within the panel.
    Perform a panel restart. If the error persists, back up the project and contact Siemens technical support or arrange for unit repair.
    Event ID: 50000
    Backup battery low or missing; the real-time clock and retentive data may not be maintained during power loss.
    Replace the internal backup battery with the correct Siemens-specified replacement. Refer to the OP 177B operating instructions for battery access procedure.
    Event ID: 60000
    Firmware update error; the firmware transfer to the panel was interrupted or the firmware file is incompatible.
    Restart the panel in transfer mode and re-initiate the firmware update using ProSave or WinCC flexible 2008 with the correct firmware version for the 6AV6343-0AA04-0MA6.

    Frequently Asked Questions

    Which engineering software is required to configure the OP 177B (6AV6343-0AA04-0MA6)?

    The OP 177B is configured using Siemens WinCC flexible 2008. Projects are transferred to the panel via MPI, PROFIBUS DP, or Ethernet connection.

    Which PLCs are compatible with the OP 177B?

    The OP 177B is primarily designed for use with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. Ethernet-based communication also allows connectivity to S7-300/400 with Ethernet-capable CPU modules.

    What is the supply voltage for the 6AV6343-0AA04-0MA6?

    The panel operates on 24 V DC. The supply must be within the specified tolerance range as defined in the OP 177B operating instructions.

    Does the OP 177B support touch input?

    Yes, the OP 177B supports both touch screen input and physical membrane keypad operation, allowing use in environments where gloved or tactile key operation is preferred.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within tolerance and that the connector is fully seated.

    Correct any supply voltage issues. If voltage is confirmed correct and the display remains blank, the internal power supply or backlight may have failed and the unit should be sent for repair.

    Panel cannot communicate with the S7 PLC via MPI or PROFIBUS

    Verify the MPI/PROFIBUS cable is connected to the correct port and that the bus termination resistors are properly set at both ends of the network. Check the bus address configured on the panel matches the project settings.

    Correct cable connections and termination. Adjust the bus address on the panel via the Start Center settings menu to match the project configuration, then restart the panel.

    Project transfer fails when attempting to download from WinCC flexible 2008

    Confirm the transfer mode is active on the panel (accessible via Start Center > Transfer). Check that the communication interface selected in WinCC flexible matches the physical connection being used (Ethernet or MPI/PROFIBUS).

    Activate transfer mode on the panel, ensure correct interface settings in WinCC flexible 2008, and retry the transfer. Check firewall settings if using Ethernet transfer.

    Touchscreen input is inaccurate or unresponsive

    Check the touchscreen surface for contamination or physical damage. Verify that the touch calibration has not been corrupted by accessing the calibration routine in the panel's Start Center.

    Clean the touchscreen surface with a soft, dry cloth. Run the touch calibration routine from the Start Center. If the touchscreen remains unresponsive, the touch overlay may require replacement.

    Real-time clock resets to default time after every power cycle

    This indicates the internal backup battery is discharged or missing. The battery maintains the real-time clock and retentive memory during power-off periods.

    Replace the internal backup battery with the Siemens-specified replacement cell. Refer to the OP 177B hardware manual for the correct battery type and replacement procedure.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart