• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6343-0AA04-0MA0 OP 177B
    Awaiting product image

    Siemens 6AV6343-0AA04-0MA0 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6343-0AA04-0MA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6343-0AA04-0MA0 is the OP 177B operator panel, part of the SIMATIC HMI family of human-machine interface devices. This unit provides a monochrome STN display with a keypad-based interface for process visualization and operator control in industrial automation environments. It is designed to work seamlessly within the Siemens SIMATIC automation ecosystem, supporting direct integration with S7 PLCs and other compatible controllers.

    The OP 177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and a membrane keypad with configurable function keys for operator input. It supports PROFIBUS DP and MPI communication interfaces for direct PLC connectivity, as well as a RS-422/RS-485 serial interface. The panel includes 512 KB of user memory for project data and is configured using Siemens WinCC flexible engineering software. It operates on a 24 V DC supply and is rated IP65 at the front face for protection against dust and water ingress.

    The OP 177B is widely used in machine-level HMI applications across manufacturing, packaging, food and beverage, and process industries. Its compact keypad-based design makes it suitable for environments where touchscreen operation is impractical or where operators require tactile feedback. The panel is commonly mounted in control cabinet doors or operator stations where reliable process monitoring and parameter entry are required.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome
    Display Resolution 320 x 240 pixels
    Input Interface Membrane keypad with function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 8 W
    Communication Interface PROFIBUS DP, MPI, RS-422/RS-485
    User Memory 512 KB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible 2005 or higher

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check PROFIBUS/MPI cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to the PLC has been interrupted during runtime operation.
    Inspect physical communication cables for damage. Verify bus termination and cable shielding. Restart the HMI panel and PLC if the connection does not recover automatically.
    Event ID: 20000
    Project download error. The project could not be transferred to the HMI panel successfully.
    Check the transfer cable or network connection between the engineering PC and the panel. Ensure the panel is in transfer mode and that the WinCC flexible project is compiled without errors.
    Event ID: 40000
    System memory low. Available memory for runtime operation is insufficient.
    Reduce the project size by removing unused screens, tags, or alarm entries. Recompile and re-download the project to the panel.
    Event ID: 50000
    Internal device error or hardware fault detected during self-test at startup.
    Perform a factory reset of the panel. If the error persists after reset and re-download of the project, the panel hardware may require repair or replacement.
    Event ID: 60000
    Tag update error. One or more process tags could not be read from the PLC within the configured cycle time.
    Check PLC program to ensure the configured tag addresses exist and are accessible. Increase the tag acquisition cycle time in the WinCC flexible project if the PLC scan cycle is slow.
    Event ID: 70000
    Alarm buffer overflow. The number of pending alarms has exceeded the buffer capacity of the panel.
    Acknowledge and clear active alarms. Review the alarm configuration in WinCC flexible to reduce the number of simultaneously active alarms or increase the alarm buffer size if possible.

    Frequently Asked Questions

    What communication interfaces does the OP 177B support?

    The OP 177B supports PROFIBUS DP and MPI interfaces for direct connection to Siemens S7 PLCs, as well as RS-422/RS-485 serial communication for connection to third-party controllers.

    Which engineering software is required to configure the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2005 or a later version. Projects are compiled on a PC and downloaded to the panel via a data cable or network connection.

    Is the OP 177B compatible with Siemens S7-300 and S7-400 PLCs?

    Yes, the OP 177B can communicate directly with S7-300 and S7-400 PLCs via MPI or PROFIBUS DP without requiring an additional communication module.

    What is the front panel protection rating of the OP 177B?

    The front face of the OP 177B is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for panel door mounting in industrial environments.

    Can the OP 177B display be used in a touchscreen configuration?

    No, the 6AV6343-0AA04-0MA0 OP 177B is a keypad-operated panel and does not feature a touchscreen. Operator input is performed exclusively via the integrated membrane keypad and function keys.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within the specified tolerance. Inspect the internal fuse if accessible.

    Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct and the display remains blank, the internal power supply or display backlight may have failed and the unit should be sent for repair.

    Panel fails to communicate with the PLC

    Verify the PROFIBUS or MPI cable is correctly connected and terminated. Check the bus address configured on the panel matches the address set in the WinCC flexible project and the PLC network configuration.

    Correct any address mismatches in the project configuration. Replace damaged cables and ensure proper bus termination resistors are installed at both ends of the PROFIBUS segment. Restart both the panel and the PLC.

    Project download fails or transfer does not start

    Confirm the panel is set to transfer mode by pressing the appropriate key combination at startup. Check the PC-to-panel cable or network connection. Verify the WinCC flexible project compiles without errors.

    Place the panel in transfer mode manually. Use a known-good USB or serial transfer cable. Recompile the project in WinCC flexible and retry the download. If the panel is unresponsive, perform a factory reset using the panel's boot menu.

    Function keys do not respond to operator input

    Check for physical damage to the membrane keypad surface. Verify that the key functions are correctly assigned in the WinCC flexible project and that the project has been downloaded successfully.

    If keys are physically damaged, the keypad membrane assembly requires replacement. If the hardware is intact, review and correct the key assignments in the WinCC flexible project and re-download to the panel.

    Panel repeatedly restarts or enters an error loop at startup

    Attempt to access the panel's boot menu during startup. Check whether a corrupted project or a failed firmware update is causing the restart loop.

    Boot the panel into service mode and perform a factory reset to clear the project memory. Re-download a freshly compiled WinCC flexible project. If the panel continues to restart after a clean project download, the internal hardware requires professional repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart