Siemens 6AV6343-0AA04-0CB0 OP 177B
€ 1.995,00
The Siemens 6AV6343-0AA04-0CB0 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome STN display and is part of the OP 177B product family, which bridges the gap between basic text panels and full graphical panels. It is a compact, panel-mount HMI device intended for use with Siemens SIMATIC controllers and compatible third-party PLCs.
The OP 177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and supports touch and function key operation. It includes interfaces such as PROFIBUS DP and MPI for direct connection to SIMATIC S7 controllers, as well as a RS-422/RS-485 serial interface for third-party connectivity. The panel runs on WinCC flexible runtime software and supports configuration via WinCC flexible 2004 or later. It operates on 24 V DC supply and offers a robust membrane keypad with configurable function keys for operator input.
The OP 177B is widely deployed in manufacturing, process automation, and machine building environments where a reliable, mid-range operator interface is required. It is commonly found on packaging machinery, conveyor systems, injection molding machines, and general-purpose industrial equipment. Its compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a standard choice for system integrators working within the Siemens automation ecosystem.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome |
| Display Resolution | 320 x 240 pixels |
| Display Colors | Monochrome (blue/white) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 8 W |
| Communication Interface | MPI, PROFIBUS DP, RS-422/RS-485 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode. - Event ID: 10001
- Connection to PLC interrupted during operation. The HMI lost communication with the controller after a previously established connection.
Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify network topology and bus termination. - Event ID: 20000
- Project download error. The HMI was unable to receive or apply a project transferred from the engineering station.
Verify the transfer cable connection and PC interface settings. Ensure WinCC flexible project is compiled without errors before transfer. Check available memory on the HMI device. - Event ID: 40000
- Tag read error. The HMI panel cannot read the value of a configured PLC tag or variable.
Verify the PLC address (DB, MW, etc.) configured in the HMI project matches the actual PLC program. Check that the PLC is in RUN mode and the data block exists. - Event ID: 40001
- Tag write error. The HMI panel cannot write a value to the configured PLC tag or variable.
Check that the target PLC address is not write-protected. Verify the data type configured in the HMI project matches the PLC variable type. Confirm the PLC is in RUN mode. - Event ID: 50000
- System memory low. The available runtime memory on the HMI device is insufficient for the loaded project.
Reduce the number of active screens or objects in the project. Archive or delete unnecessary log data stored on the device. Consider simplifying the HMI project structure. - Event ID: 60000
- Operating system or firmware error detected. An internal system fault has occurred on the HMI panel.
Perform a controlled restart of the HMI panel. If the fault persists, reload the firmware using the Siemens ProSave tool and re-transfer the project.
Frequently Asked Questions
Which PLCs are compatible with the OP 177B (6AV6343-0AA04-0CB0)?
The OP 177B is primarily designed for use with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports connectivity to third-party controllers via the RS-422/RS-485 serial interface using standard protocols.
What software is required to configure the OP 177B?
The OP 177B is configured using Siemens WinCC flexible 2004 or a later version. The project is then transferred to the panel via a PC adapter cable connected to the MPI interface or via a USB-to-MPI adapter.
What is the supply voltage for the 6AV6343-0AA04-0CB0?
The OP 177B operates on a 24 V DC supply voltage. The power consumption is a maximum of 8 W under normal operating conditions.
Does the OP 177B support touchscreen input?
The OP 177B (6AV6343-0AA04-0CB0) supports both touch input on the display area and physical function keys on the membrane keypad, allowing flexible operator interaction.
What is the front panel protection rating of the OP 177B?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector on the rear of the unit. Check that the supply is within the specified tolerance and that the connector is fully seated.
Restore the 24 V DC supply to within specification. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and the unit should be sent for repair or replacement.
HMI panel shows 'No connection to PLC' or communication error on screen
Check the MPI or PROFIBUS DP cable connections at both the HMI and PLC ends. Verify bus termination is correctly applied at both ends of the network segment.
Replace or reseat the communication cable. Correct the bus address settings in the HMI project to match the PLC configuration. Ensure only the two physical end nodes have bus termination resistors active.
Project transfer from PC to HMI fails or times out
Verify the PC adapter (USB-MPI or PC-MPI) is correctly installed and the COM port or USB driver is functioning. Check that the HMI is in Transfer mode before initiating the download.
Set the HMI to Transfer mode via the Start Center menu. Confirm the correct interface and baud rate are selected in WinCC flexible Transfer settings. Try a different PC adapter cable if the issue persists.
Touchscreen input is inaccurate or unresponsive
Check whether the touch calibration has drifted. Access the calibration utility from the HMI Start Center or Control Panel menu.
Recalibrate the touchscreen using the built-in calibration tool in the HMI operating system. If the touch layer is physically damaged or unresponsive after calibration, the touch foil or display assembly requires replacement.
HMI panel continuously reboots or fails to load the project
This may indicate corrupted project data or a firmware issue. Attempt to access the Start Center during boot by pressing the appropriate key combination.
Use the Siemens ProSave tool to reload the firmware to the correct version, then re-transfer the WinCC flexible project. If the unit still fails to boot correctly, the internal flash memory may be faulty and hardware repair is required.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page