Siemens 6AV6343-0AA04-0CA0 OP 177B
€ 1.995,00
The Siemens 6AV6343-0AA04-0CA0 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome STN display and is part of the OP 177B product family, which bridges the gap between basic text-based panels and full graphical touchscreen terminals. It is manufactured by Siemens and operates within the SIMATIC automation environment.
The OP 177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and supports both touch and key-based operation through its integrated membrane keypad. It includes MPI/PROFIBUS DP and RS-422/RS-485 interfaces for communication with SIMATIC S7 PLCs and third-party controllers, and is configurable via WinCC flexible software. The panel provides 512 KB of user memory for project data and supports recipe management, alarm logging, and trend display functions.
The OP 177B is widely deployed in manufacturing, packaging, and process automation environments where reliable operator control and monitoring at the machine level is required. Its compact panel-mount design and compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs make it suitable for a broad range of industrial machinery. The unit is also used in applications requiring robust HMI functionality in environments with moderate space constraints and standard industrial protection requirements.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome |
| Display Resolution | 320 x 240 pixels |
| Display Colors | Monochrome (blue/white) |
| Touch Technology | Resistive touch + membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 8 W |
| Communication Interface | MPI/PROFIBUS DP, RS-422/RS-485 |
| User Memory | 512 KB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during startup; project data may be corrupted or incompatible with the panel firmware version.
Re-transfer the project using WinCC flexible. Ensure the firmware version on the panel matches the WinCC flexible version used for configuration. - Event ID: 10001
- Communication connection to the PLC has been lost or cannot be established.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration. - Event ID: 20000
- Internal device error; a system fault has been detected in the panel hardware or firmware.
Perform a panel reset. If the error persists, update the firmware or return the unit for service. - Event ID: 40000
- Project download failed; transfer of configuration data from the engineering PC to the panel was interrupted or unsuccessful.
Check the transfer cable and PC interface settings. Restart the panel in transfer mode and retry the download via WinCC flexible. - Event ID: 50000
- Alarm buffer overflow; the number of pending alarms has exceeded the panel's alarm buffer capacity.
Acknowledge and clear existing alarms. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers. - Event ID: 60000
- Recipe data error; recipe records could not be read from or written to the internal memory.
Check available memory on the panel. Re-transfer the project and verify recipe configuration in WinCC flexible. - Event ID: 70000
- Firmware update error; the firmware update process was interrupted or the firmware file is incompatible.
Restart the panel and retry the firmware update using the correct firmware version from the Siemens support portal.
Frequently Asked Questions
What PLC families are compatible with the OP 177B (6AV6343-0AA04-0CA0)?
The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports communication with third-party controllers via RS-422/RS-485 using standard protocols.
What software is used to configure the OP 177B?
The OP 177B is configured using Siemens WinCC flexible software. Projects are transferred to the panel via the MPI/PROFIBUS DP interface or a serial PC/PPI cable.
What is the supply voltage for the 6AV6343-0AA04-0CA0?
The panel operates on 24 V DC. The supply must be within the specified tolerance range to ensure reliable operation.
Does the OP 177B support recipe and alarm management?
Yes, the OP 177B supports recipe management, alarm logging, and trend display functions as part of its standard feature set, configurable through WinCC flexible.
What is the front panel protection rating of the OP 177B?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for use in environments where dust and water spray may be present.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power connector. Check that the supply is within the specified tolerance and that the power connector is fully seated.
Restore the correct 24 V DC supply. If the supply is correct and the display remains blank, the internal power supply or backlight may be faulty and the unit should be sent for repair.
Panel cannot establish communication with the PLC
Verify MPI/PROFIBUS DP cable connections, bus termination, and that the panel address and baud rate match the PLC network settings. Check for cable damage or incorrect wiring.
Correct any wiring or configuration mismatches. Ensure bus termination resistors are enabled only at both ends of the network. Re-download the project if communication parameters were changed.
Touchscreen does not respond or responds inaccurately
Check for physical damage to the touch surface. Attempt to recalibrate the touchscreen through the panel's start center or service menu.
Perform a touchscreen calibration. If calibration does not resolve the issue, the touch foil or controller may be damaged and the unit requires hardware repair.
Project transfer from WinCC flexible fails
Confirm the panel is in transfer mode. Check the communication cable between the PC and the panel, and verify the correct interface and transfer settings in WinCC flexible.
Restart the panel in transfer mode by holding the appropriate key combination during boot. Retry the transfer with the correct PC interface settings selected in WinCC flexible.
Panel repeatedly restarts or shows a system error on boot
A corrupted project or incompatible firmware version may cause boot loops. Attempt to access the panel's start center during startup to check firmware and project status.
Reset the panel to factory defaults via the start center and re-transfer a compatible project. If the issue persists, perform a firmware update using the correct version from the Siemens support portal.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page