Siemens 6AV6341-1FC04-0AY0 OP 177B
€ 1.995,00
The Siemens 6AV6341-1FC04-0AY0 is an OP 177B operator panel belonging to the SIMATIC HMI family, designed for machine-level visualization and operator control in industrial automation environments. This unit provides a compact, panel-mounted interface for process monitoring and control, and is part of Siemens' established line of operator panels configured and managed via WinCC flexible engineering software. The OP 177B series bridges the gap between basic text-based displays and full graphical touchscreen panels, offering a monochrome or color STN display depending on the specific variant.
The 6AV6341-1FC04-0AY0 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA) and supports both touch and key-based operation through integrated function keys and a membrane keypad. It is equipped with MPI/PROFIBUS DP and RS-422/RS-485 interfaces for direct connection to SIMATIC S7 PLCs and third-party controllers, and includes a USB interface for project transfer and peripheral connectivity. The panel operates on 24 V DC supply voltage and provides onboard flash memory for project storage, with support for recipe management, alarm logging, and trend displays.
The OP 177B is widely deployed in machine building, packaging machinery, conveyor systems, and process plant applications where a reliable, mid-range HMI solution is required. Its compatibility with the SIMATIC S7-200, S7-300, and S7-400 PLC families makes it a versatile choice for both new installations and retrofit projects. The rugged panel-mount design and broad operating temperature range make it suitable for use in demanding industrial environments such as automotive assembly lines, food and beverage production, and material handling systems.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Type | STN color LCD |
| Display Colors | 256 colors |
| Operation Mode | Touch and key operation |
| Function Keys | 14 function keys (F1-F14) with LEDs |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 10 W |
| Communication Interface | MPI/PROFIBUS DP, RS-422/RS-485, USB |
| Memory | 4 MB flash (user memory) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 1000
- Configuration error: The project loaded on the panel is incompatible or corrupt.
Re-transfer the project using WinCC flexible. Verify the project was compiled without errors before transfer. - Event ID: 10000
- Communication error: Connection to the PLC has been lost or cannot be established.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. - Event ID: 10001
- Timeout error: No response received from the configured PLC within the timeout period.
Verify PLC is in RUN mode and the communication parameters (baud rate, station address) are correctly configured on both the HMI and PLC. - Event ID: 20000
- Tag read error: The HMI cannot read the specified PLC tag or address.
Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory area. Check PLC program for address conflicts. - Event ID: 20001
- Tag write error: The HMI cannot write to the specified PLC tag or address.
Check that the target PLC memory area is not write-protected. Verify the tag address and data type in the HMI project configuration. - Event ID: 40000
- System memory low: Available runtime memory on the panel is critically low.
Reduce the number of active alarms or logged data entries. Consider archiving or clearing alarm and data logs stored on the device. - Event ID: 50000
- Recipe data error: A recipe record could not be read or written correctly.
Check recipe configuration in WinCC flexible. Verify that recipe data tags are correctly mapped to valid PLC addresses.
Frequently Asked Questions
Which PLCs are compatible with the OP 177B (6AV6341-1FC04-0AY0)?
The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports connections to third-party controllers via the RS-422/RS-485 serial interface using appropriate communication drivers in WinCC flexible.
What software is required to configure and program this HMI panel?
The OP 177B is configured using Siemens WinCC flexible 2008 or later. Projects are transferred to the panel via USB or MPI/PROFIBUS DP connection.
What is the supply voltage for the 6AV6341-1FC04-0AY0?
The panel requires a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current, typically at least 1 A, to power the unit reliably.
Does the OP 177B support alarm logging and trend displays?
Yes, the OP 177B supports alarm logging, recipe management, and trend displays as part of its standard runtime functionality when configured in WinCC flexible.
What is the IP protection rating of the OP 177B front panel?
The front panel of the OP 177B achieves IP65 protection when correctly installed in a panel cutout with the supplied seal, making it suitable for environments with dust and water spray.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that the voltage is within the acceptable range and that the connector is fully seated.
Restore the supply voltage to the correct level. If voltage is correct and the display remains blank, the internal power supply or backlight inverter may be faulty and the unit may require repair or replacement.
HMI shows 'No connection to PLC' or communication error on startup
Check the MPI or PROFIBUS DP cable connections at both the HMI and PLC ends. Verify bus termination is active only at the two physical ends of the network segment.
Correct any loose or damaged cable connections. Ensure the MPI/PROFIBUS station addresses and baud rate configured in the HMI project match the PLC settings. Replace faulty cables or connectors as needed.
Project transfer via USB fails or is not recognized
Verify the USB cable is functional and that the correct USB driver for the OP 177B is installed on the engineering PC. Check that the panel is in transfer mode.
Place the panel in transfer mode via the Start Center menu. Use a known-good USB cable and ensure WinCC flexible is set to transfer via USB. Reinstall the USB driver on the PC if necessary.
Touchscreen does not respond accurately or is misaligned
The touchscreen calibration may have drifted. Access the calibration utility through the panel's Start Center or Control Panel menu.
Perform a touchscreen recalibration using the built-in calibration tool in the panel's operating system menu. Follow the on-screen prompts to touch the calibration targets accurately.
Panel repeatedly restarts or enters a boot loop
This may indicate a corrupt or incompatible project file loaded on the panel, or a hardware fault. Attempt to access the Start Center during boot by pressing the appropriate key combination.
Enter the Start Center and delete the existing project, then re-transfer a freshly compiled project from WinCC flexible. If the boot loop persists without a project loaded, the panel firmware may need to be updated or the unit may require service.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page