• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1EC34-0AY0 OP 77B
    Awaiting product image

    Siemens 6AV6341-1EC34-0AY0 OP 77B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1EC34-0AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1EC34-0AY0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels series. It is a compact, key-operated operator panel designed for straightforward machine-level visualization and control tasks. This unit provides a monochrome display with a numeric and function key interface, making it suitable for applications where a full touchscreen is not required.

    The OP 77B features a 4-line STN monochrome LCD display capable of showing text and simple graphics. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and supports alarm management, recipe handling, and trend display functions. It operates on a 24 V DC supply and is rated IP65 at the front panel for protection against dust and water ingress.

    The OP 77B is widely used in manufacturing, packaging, and process automation environments where a cost-effective, robust operator interface is needed at the machine level. Its compact form factor and membrane keypad make it well suited for installation in control cabinet doors or machine panels with limited space. Industries such as food and beverage, automotive assembly, and general factory automation commonly deploy this panel for local operator interaction with SIMATIC-based control systems.

    Technical Specifications

    Display Type STN monochrome LCD
    Display Lines 4 lines of text
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 5 W
    Communication Interface MPI, PROFIBUS DP
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected during startup; the loaded project is incompatible or corrupt.
    Reload the project using WinCC flexible and ensure the project version matches the panel firmware version.
    Event ID: 20000
    Communication error on MPI or PROFIBUS DP interface; connection to the PLC has been lost.
    Check MPI/PROFIBUS cable connections, verify bus termination resistors, and confirm the PLC address settings match the panel configuration.
    Event ID: 40000
    Tag read error; the panel cannot read a configured tag from the connected PLC.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check PLC program is running.
    Event ID: 50000
    Tag write error; the panel cannot write a value to the configured PLC tag.
    Check that the target PLC memory area is not write-protected and that the tag address is correctly configured in the project.
    Event ID: 60000
    Alarm buffer overflow; the number of pending alarms exceeds the panel buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration to reduce simultaneous alarm triggers if this occurs frequently.
    Event ID: 70000
    Recipe data error; a recipe record could not be read or written correctly.
    Check recipe configuration in WinCC flexible. Verify that the recipe data record structure matches the PLC data block layout.
    Event ID: 80000
    System memory low warning; available panel memory is insufficient for current operations.
    Reduce the project size by removing unused screens, tags, or alarms. Transfer the optimized project back to the panel.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with SIMATIC S5 controllers using appropriate protocol settings.

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via the MPI interface or a PC adapter cable.

    What is the supply voltage for the 6AV6341-1EC34-0AY0?

    The panel requires a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to avoid damage or erratic operation.

    Is the OP 77B front panel rated for washdown environments?

    The front panel carries an IP65 protection rating, making it resistant to dust and low-pressure water jets. The rear of the unit is rated IP20 and must be protected from moisture and contamination.

    Can the OP 77B display graphical elements or only text?

    The OP 77B monochrome LCD supports basic graphics in addition to text, but its primary design is for text-based operator interaction using function keys and numeric input.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel power connector. Check for blown fuses in the supply circuit and verify polarity of the supply connection.

    Restore correct 24 V DC supply voltage. Replace any blown fuses in the supply line. If the supply is confirmed correct and the display remains blank, the internal power supply or display unit may require replacement.

    Panel shows communication error and cannot connect to PLC

    Check MPI or PROFIBUS DP cable continuity and connector seating. Verify bus termination is applied only at the physical ends of the bus. Confirm the panel node address does not conflict with other devices on the bus.

    Replace or reseat the communication cable. Correct bus termination by adding or removing termination resistors as required. Adjust the panel or PLC node address in WinCC flexible to eliminate address conflicts.

    Project transfer from PC to panel fails

    Verify the PC adapter cable type is compatible with the panel MPI port. Check that WinCC flexible project settings match the panel type and firmware version. Confirm the correct COM port or USB adapter is selected in the transfer settings.

    Use a Siemens-compatible MPI PC adapter. Update the panel firmware if the project requires a newer version. Select the correct interface in WinCC flexible transfer settings and retry the download.

    Function keys do not respond to presses

    Inspect the membrane keypad for physical damage, contamination, or deformation. Check whether the issue is limited to specific keys or affects all keys. Test key response in the panel's built-in service menu if accessible.

    Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly requires replacement. Contact a qualified repair technician for membrane keypad replacement.

    Alarms are not displayed on the panel

    Verify that alarm tags are correctly configured in WinCC flexible and that the corresponding PLC bit addresses are active. Check that the alarm view screen is included in the project and accessible to the operator.

    Correct the alarm tag addresses in WinCC flexible to match the PLC program. Ensure the alarm screen is properly linked in the project navigation. Re-transfer the corrected project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart