• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1BA13-1AY0 OP 17
    Awaiting product image

    Siemens 6AV6341-1BA13-1AY0 OP 17

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1BA13-1AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1BA13-1AY0 is an Operator Panel (OP 17) belonging to the SIMATIC HMI family, designed for operator control and monitoring tasks in industrial automation environments. This unit provides a compact, text-based interface for machine-level visualization and process control. It is part of the OP series of operator panels, which are widely used in conjunction with Siemens SIMATIC PLCs and other compatible controllers.

    The OP 17 features a backlit LCD display capable of showing multiple lines of text and numeric values, with a membrane keypad for operator input. It supports the MPI (Multi-Point Interface) and PROFIBUS-DP communication protocols, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using ProTool software and supports recipe management, alarm logging, and trend display functions. The unit operates on a 24 V DC supply and is rated to IP65 at the front panel, making it suitable for panel-door mounting in industrial enclosures.

    The OP 17 is commonly deployed in manufacturing, process automation, and machine building applications where a cost-effective, robust operator interface is required. It is well suited for tasks such as parameter entry, alarm acknowledgment, and status monitoring on standalone machines or production lines. Industries including automotive, food and beverage, packaging, and general manufacturing frequently use this panel for local HMI functionality at machine level.

    Technical Specifications

    Display Type Backlit LCD
    Display Lines 4 lines of text
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 5 W
    Communication Interface MPI, PROFIBUS-DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +70 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Configuration Software ProTool
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 10000
    No connection to the configured controller. Communication between the OP 17 and the PLC cannot be established.
    Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify PLC address settings match the OP 17 configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the controller has been interrupted during operation.
    Inspect communication cables for damage or loose connectors. Check bus termination and cable shielding. Restart the OP 17 and verify PLC communication parameters.
    Event ID: 20000
    Configuration data error. The project data loaded on the OP 17 is invalid or corrupted.
    Re-download the project from ProTool to the OP 17. Verify the project was compiled without errors before transfer.
    Event ID: 40000
    Operating system error on the OP 17. Internal firmware or system fault detected.
    Perform a reset of the OP 17. If the fault persists, reload the operating system firmware using the appropriate Siemens tool.
    Event ID: 50000
    Data record transfer error. A recipe or data record could not be read or written correctly.
    Check the data record configuration in ProTool. Verify PLC data block addresses match the configured data areas in the project.
    Event ID: 60000
    Alarm buffer overflow. The number of pending alarms exceeds the buffer capacity of the OP 17.
    Acknowledge and clear existing alarms. Review the alarm configuration to reduce simultaneous alarm occurrences or increase acknowledgment frequency.
    Event ID: 70000
    Printer communication error. The OP 17 cannot communicate with the configured printer.
    Check the printer cable connection and printer power status. Verify the printer type and port settings in the ProTool project configuration.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP 17 (6AV6341-1BA13-1AY0)?

    The OP 17 is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP. It also supports connection to S5 series PLCs using appropriate adapters and drivers configured in ProTool.

    What software is used to configure the OP 17?

    The OP 17 is configured using Siemens ProTool software. Projects are created on a PC and then downloaded to the panel via the MPI interface or a serial programming cable.

    What is the supply voltage for the 6AV6341-1BA13-1AY0?

    The OP 17 requires a 24 V DC power supply. The supply must be within the specified tolerance range to ensure reliable operation.

    What is the front panel protection rating of the OP 17?

    The front panel of the OP 17 is rated to IP65, making it resistant to dust ingress and low-pressure water jets, suitable for panel-door mounting in industrial environments.

    Can the OP 17 display graphical content or only text?

    The OP 17 is a text-based operator panel and does not support graphical display. It is capable of displaying alphanumeric characters, status values, and alarm messages in a text format across its LCD lines.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the supply is within the specified tolerance. Inspect internal fuse if accessible.

    Restore correct 24 V DC supply voltage. Replace any blown internal fuse. If the display backlight has failed, the panel may require repair or replacement of the backlight component.

    OP 17 shows 'No Connection' or communication error at startup

    Verify MPI or PROFIBUS-DP cable connections between the OP 17 and the PLC. Check that bus termination resistors are correctly placed at both ends of the bus. Confirm the PLC address in the ProTool project matches the physical PLC setting.

    Correct any wiring faults or loose connectors. Enable bus termination on the first and last devices on the bus. Adjust the PLC address in the project and re-download to the OP 17 if necessary.

    Keypad buttons not responding or responding incorrectly

    Inspect the membrane keypad for physical damage, contamination, or wear. Test individual keys to identify whether the fault is isolated to specific keys or affects the entire keypad.

    Clean the keypad surface with a dry cloth. If individual keys are damaged or non-functional, the membrane keypad assembly should be replaced. Contact a qualified repair technician for keypad replacement.

    Project download from ProTool fails or is incomplete

    Check the serial or MPI cable connection between the PC and the OP 17. Verify the correct communication port and transfer settings are selected in ProTool. Ensure the OP 17 is in transfer mode before initiating the download.

    Replace or reseat the programming cable. Select the correct COM port and baud rate in ProTool transfer settings. Restart the OP 17 in transfer mode by holding the appropriate key combination during power-on and retry the download.

    Alarms are displayed but cannot be acknowledged

    Check the alarm configuration in the ProTool project to verify that acknowledgment is enabled for the relevant alarm class. Confirm the PLC bit associated with alarm acknowledgment is being correctly processed.

    Correct the alarm class configuration in ProTool to enable operator acknowledgment. Verify the PLC logic correctly handles the acknowledgment bit. Re-download the updated project to the OP 17.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart