• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1BA23-0AY0 OP 27
    Awaiting product image

    Siemens 6AV6341-1BA23-0AY0 OP 27

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1BA23-0AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1BA23-0AY0 is an Operator Panel (OP 27) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a monochrome graphical display for process visualization and operator control, and is part of the OP 27 series which was widely deployed across manufacturing and process industries. The 6AV6341-1BA23-0AY0 variant is a Siemens-manufactured replacement or compatible unit within the OP 27 product line.

    The OP 27 features a 5.7-inch STN monochrome LCD display with a resolution of 320 x 240 pixels, offering clear visualization of process data, alarms, and operator prompts. It communicates via MPI (Multi-Point Interface) and PROFIBUS-DP, enabling direct integration with SIMATIC S7-300 and S7-400 PLCs. The panel includes a membrane keypad with function keys, numeric keys, and system keys for operator input, and supports configuration via Siemens ProTool or WinCC flexible engineering software. Onboard flash memory stores project data and recipes, and the unit operates from a 24 V DC supply.

    The OP 27 is commonly used in machine tools, packaging machinery, conveyor systems, and process automation installations where a robust, panel-mounted operator interface is required. Its compatibility with the SIMATIC S7 controller family makes it a standard choice for retrofitting or maintaining existing Siemens automation systems. The unit is suited for applications requiring reliable alarm management, recipe handling, and process data display in industrial environments.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome LCD
    Display Resolution 320 x 240 pixels
    Input Voltage 24 V DC
    Power Consumption Max. 15 W
    Communication Interface MPI, PROFIBUS-DP
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Input Method Membrane keypad
    Series/Product Family SIMATIC HMI OP 27
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 27 and the connected PLC. The panel cannot establish or maintain a connection via MPI or PROFIBUS-DP.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address settings match the OP 27 configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Timeout error on the MPI or PROFIBUS-DP bus. The panel did not receive a response from the PLC within the expected time.
    Check bus cable integrity and connector pins. Verify baud rate settings are consistent across all devices on the bus. Check for bus termination at both ends.
    Event ID: 20000
    Project download error. A fault occurred during the transfer of the configuration project from the engineering PC to the OP 27.
    Verify the serial or MPI connection between the PC and the OP 27. Ensure the ProTool or WinCC flexible project is compatible with the OP 27 firmware version. Retry the download.
    Event ID: 40000
    Internal hardware fault detected on the OP 27. A self-diagnostic check has identified a hardware error.
    Cycle power to the unit. If the fault persists, the unit may require repair or replacement of the internal electronics.
    Event ID: 50000
    Memory error. The panel has detected a fault in the internal flash memory or project data is corrupted.
    Reload the project from the engineering PC. If the error persists, perform a factory reset and re-download the project. Replace the unit if memory failure is confirmed.
    Event ID: 60000
    Alarm buffer overflow. The number of pending alarms has exceeded the capacity of the alarm buffer.
    Acknowledge and clear existing alarms. Review the alarm configuration in the project to ensure alarm limits are set appropriately and spurious alarms are suppressed.
    Event ID: 70000
    Recipe data error. A fault occurred when reading or writing recipe data, possibly due to data inconsistency or memory issues.
    Check recipe configuration in the engineering project. Re-download the project and verify recipe data integrity. Ensure sufficient memory is available for recipe storage.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 27 (6AV6341-1BA23-0AY0)?

    The OP 27 is compatible with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It can also communicate with S5 PLCs using appropriate protocol adapters.

    What engineering software is required to configure the OP 27?

    The OP 27 is configured using Siemens ProTool or WinCC flexible engineering software. ProTool/Pro CS was the primary tool for this panel generation, and WinCC flexible 2008 also supports it.

    What is the supply voltage for the OP 27?

    The OP 27 operates on a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current, typically up to 15 W.

    What is the IP protection rating of the OP 27?

    The front panel of the OP 27 is rated IP65, making it suitable for panel-mounted installations where protection against dust and water jets is required.

    Can the OP 27 display graphics and trend curves?

    Yes, the OP 27 supports graphical display elements including bar graphs and trend curves, in addition to text-based process values and alarm messages, within the limits of its 320 x 240 monochrome display.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector. Check internal fuse if accessible. Verify the power supply unit is functioning correctly.

    Restore correct 24 V DC supply voltage. Replace the internal fuse if blown. If the display backlight has failed, the backlight or display assembly may require replacement.

    OP 27 cannot communicate with the PLC

    Check MPI or PROFIBUS-DP cable connections at both the OP 27 and PLC ends. Verify bus termination resistors are correctly placed at both ends of the bus. Confirm that the PLC address configured in the OP 27 project matches the actual PLC MPI address.

    Reseat all connectors and replace damaged cables. Set correct bus termination. Correct the PLC address in the ProTool or WinCC flexible project and re-download to the panel.

    Project download fails or is interrupted

    Verify the MPI or serial connection between the engineering PC and the OP 27. Check that the firmware version on the OP 27 is compatible with the project version in ProTool or WinCC flexible.

    Use a known-good MPI adapter or PC/PPI cable. Update the OP 27 firmware if a version mismatch exists. Retry the download after ensuring a stable connection.

    Membrane keypad keys are unresponsive or intermittent

    Inspect the membrane keypad overlay for physical damage, contamination, or delamination. Test individual keys in the OP 27 diagnostics or key test mode if available.

    Clean the keypad surface. If keys are physically damaged or the membrane is worn, replace the membrane keypad assembly. This is a common wear item on older OP 27 units.

    Alarms are displayed but cannot be acknowledged

    Check the alarm configuration in the project to verify that acknowledgment is enabled for the relevant alarm class. Confirm the PLC bit associated with alarm acknowledgment is being correctly processed.

    Correct the alarm class configuration in the engineering project and re-download. Verify PLC logic for alarm acknowledgment bits is functioning correctly.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart