Siemens 6AV6341-1BA13-0AY0 OP 17
The Siemens 6AV6341-1BA13-0AY0 is an OP 17 operator panel belonging to the SIMATIC HMI family of operator panels. This compact text-based display unit is designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring process values and entering parameters. The OP 17 series is a well-established panel in Siemens' portfolio, offering reliable operation in industrial environments.
The OP 17 features a backlit LCD display capable of showing multiple lines of text and numeric values, with a membrane keypad for operator input. It communicates with SIMATIC S5 and S7 PLCs via the MPI or PROFIBUS DP interface, enabling direct integration into existing Siemens automation networks. The panel supports configuration via ProTool software and stores configured projects in internal flash memory, allowing retention of data without battery backup. Operating on a 24 V DC supply, the unit is built to withstand the electrical noise typical of industrial environments.
The OP 17 is widely deployed in manufacturing, packaging, and process automation applications where a cost-effective, text-based operator interface is sufficient. It is commonly found on standalone machines and production lines where operators need to monitor status messages, acknowledge alarms, and adjust setpoints without requiring a full graphical display. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine enclosures across a broad range of industries.
Technical Specifications
| Display Type | LCD, backlit |
|---|---|
| Display Lines | 4 lines of text |
| Characters per Line | 20 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 6 W |
| Communication Interface | MPI / PROFIBUS DP |
| Configuration Software | ProTool |
| Memory | Internal flash memory |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| IP Rating (Front) | IP65 |
| Mounting | Panel mount |
| Certifications | CE, UL |
Common Error Codes & System Events
- System Error 1
- Configuration data in flash memory is invalid or corrupted.
Re-download the project configuration from ProTool to the OP 17 via the MPI/PROFIBUS interface. - System Error 2
- Communication connection to the PLC has been lost or cannot be established.
Check MPI/PROFIBUS cable connections, verify bus address settings, and confirm PLC is powered and running. - System Error 4
- Overflow in the alarm buffer; too many unacknowledged alarms pending.
Acknowledge pending alarms on the panel and review the alarm configuration in ProTool to adjust buffer size if necessary. - System Error 6
- Incorrect or incompatible project file loaded onto the device.
Verify that the project was compiled for the OP 17 in ProTool and re-transfer the correct project file. - System Error 8
- Internal device fault detected during self-test at startup.
Cycle power to the unit. If the fault persists, the panel may require repair or replacement of internal components. - PLC No. X Not Available
- The configured PLC with the specified station address is not responding on the bus.
Verify the PLC station address matches the ProTool configuration, check bus termination resistors, and inspect cable integrity. - Receive Timeout
- The OP 17 did not receive a response from the PLC within the configured timeout period.
Check network load on the MPI/PROFIBUS bus, verify baud rate settings match on all devices, and inspect cable shielding and grounding.
Frequently Asked Questions
Which PLCs are compatible with the OP 17 (6AV6341-1BA13-0AY0)?
The OP 17 is compatible with Siemens SIMATIC S7-200, S7-300, S7-400, and S5 PLCs via MPI or PROFIBUS DP interfaces. Compatibility depends on the specific communication driver configured in ProTool.
What software is used to configure the OP 17?
The OP 17 is configured using Siemens ProTool software. Projects are compiled in ProTool and transferred to the panel via the MPI or PROFIBUS DP interface.
What is the supply voltage for the 6AV6341-1BA13-0AY0?
The OP 17 operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI operator panels.
Does the OP 17 require a battery for memory retention?
No, the OP 17 stores its project configuration in internal flash memory, which does not require a battery backup to retain data when power is removed.
What is the front panel protection rating of the OP 17?
The front panel of the OP 17 is rated to IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for typical industrial machine environments.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the supply is within the specified tolerance range.
Ensure the 24 V DC supply is stable and correctly wired. If the supply is correct and the display remains blank, inspect the internal fuse and replace if blown. If the fault persists, the panel may require internal repair.
'PLC Not Available' or communication error displayed at startup
Verify the MPI or PROFIBUS DP cable is securely connected at both the OP 17 and the PLC. Check that bus termination resistors are correctly placed at both ends of the bus segment.
Correct any wiring faults, ensure bus addresses are unique and match the ProTool configuration, and confirm baud rate settings are consistent across all devices on the bus.
Panel displays garbled text or incorrect characters
This typically indicates a corrupted or incompatible project file stored in the panel's flash memory.
Re-transfer the correct project file from ProTool to the OP 17. Ensure the project is compiled specifically for the OP 17 model before transfer.
Keypad buttons are unresponsive or intermittently responsive
Inspect the membrane keypad for physical damage, contamination, or wear. Check that the panel is not in a locked or protected operating mode configured in the project.
Clean the keypad surface with a dry cloth. If individual keys are mechanically damaged, the membrane keypad assembly may need to be replaced. Verify no software-level key lock is active in the project configuration.
Panel repeatedly resets or reboots during operation
Measure the 24 V DC supply for voltage dips or instability under load. Check for excessive electrical noise or ground loops in the installation.
Stabilize the power supply, ensure proper cable shielding and grounding according to Siemens installation guidelines, and verify the supply can deliver sufficient current for the panel's rated consumption.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page