Siemens 6AV6341-1BA14-0AY0 OP 17
€ 1.995,00
The Siemens 6AV6341-1BA14-0AY0 is an OP 17 operator panel belonging to the SIMATIC HMI family of operator panels. This unit is a compact, text-based operator panel designed for machine-level human-machine interface applications, providing operators with a straightforward interface for monitoring and controlling industrial processes. The OP 17 series is manufactured by Siemens and is part of the established SIMATIC HMI product line.
The OP 17 features a multi-line LCD text display capable of showing alphanumeric characters and system messages. It communicates via the MPI (Multi-Point Interface) and PROFIBUS-DP protocols, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. The panel includes a membrane keypad with function keys for operator input, and supports configuration via Siemens ProTool software. It operates on a 24 V DC supply and is designed for panel-mount installation with an IP65 protection rating on the front face.
The OP 17 is widely used in manufacturing, packaging, and process automation environments where a cost-effective, reliable text-based HMI is required at the machine level. Its compact form factor and robust membrane keypad make it suitable for installation in control cabinets and machine panels in industries such as automotive, food and beverage, and general machinery. The panel's compatibility with the SIMATIC S7 controller family makes it a common choice for retrofitting and upgrading existing Siemens-based control systems.
Technical Specifications
| Display Type | LCD, text-based |
|---|---|
| Display Lines | 4 lines of 20 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 6 W |
| Communication Interface | MPI, PROFIBUS-DP |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +70 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| Mounting | Panel mount |
| Certifications | CE, UL |
| Configuration Software | ProTool |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
Common Error Codes & System Events
- Event ID: 10000
- No connection to the configured PLC or controller. Communication link cannot be established.
Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify PLC address settings match the OP 17 configuration. - Event ID: 10001
- Communication timeout. The panel has lost communication with the PLC during operation.
Inspect cable integrity and connector seating. Check PLC program is running and MPI/PROFIBUS network is correctly configured. - Event ID: 20000
- Configuration data error. The project data loaded on the panel is invalid or corrupted.
Re-transfer the project from ProTool to the OP 17. Verify the correct project file is used for this hardware variant. - Event ID: 40000
- Operating system error. Internal firmware or OS fault detected.
Perform a factory reset and reload the operating system and project data. If the fault persists, the unit may require repair or replacement. - Event ID: 10006
- PLC address conflict. Duplicate node address detected on the MPI or PROFIBUS network.
Verify that each device on the network has a unique address. Correct address assignments in the PLC and OP 17 configuration. - Event ID: 10002
- Receive mailbox overflow. The panel cannot process incoming data from the PLC fast enough.
Reduce the number of active tags or increase the update cycle time in the ProTool project configuration. - Event ID: 20001
- Tag read/write error. A configured variable cannot be read from or written to the PLC.
Check that the PLC data block addresses referenced in the OP 17 project exist and are accessible in the PLC program.
Frequently Asked Questions
Which PLCs are compatible with the Siemens OP 17 (6AV6341-1BA14-0AY0)?
The OP 17 is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP communication interfaces.
What software is used to configure the OP 17?
The OP 17 is configured using Siemens ProTool software. Projects are then transferred to the panel via the MPI interface.
What is the supply voltage for the 6AV6341-1BA14-0AY0?
The OP 17 operates on a 24 V DC supply voltage.
What is the front panel protection rating of the OP 17?
The front panel of the OP 17 carries an IP65 protection rating, making it suitable for installation in environments with dust and water spray.
Can the OP 17 display graphics or only text?
The OP 17 is a text-based operator panel and displays alphanumeric characters only. It does not support graphical display of process images or bitmaps.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Measure voltage at the panel terminals to confirm correct supply level.
Ensure the 24 V DC supply is within tolerance. Check wiring connections at the power terminals. If supply is correct and display remains blank, the internal power supply or display unit may be faulty and require repair.
No communication with PLC after installation
Verify MPI or PROFIBUS-DP cable is correctly connected and terminated. Check that the node address configured in the OP 17 project matches the physical network settings.
Correct any address conflicts, ensure proper bus termination at both ends of the network, and re-transfer the project to the panel. Confirm the PLC is in RUN mode.
Panel repeatedly displays 'No Connection' message during operation
Inspect the MPI or PROFIBUS cable for damage, loose connectors, or missing termination resistors. Check network load and cable length against PROFIBUS specifications.
Replace damaged cables, secure all connectors, and add or correct termination resistors. Reduce network cable length or add repeaters if the bus length exceeds specification.
Project transfer from ProTool fails or is incomplete
Check the transfer cable connection between the PC and the OP 17 MPI port. Verify that the panel is set to transfer mode and that the correct COM port or USB-MPI adapter is selected in ProTool.
Use a Siemens-compatible MPI programming cable or USB-MPI adapter. Set the OP 17 to transfer mode via the panel menu before initiating the download from ProTool.
Function keys do not respond to presses
Inspect the membrane keypad for physical damage or contamination. Test each key in the panel's diagnostic or test mode if available.
Clean the keypad surface. If keys remain unresponsive, the membrane keypad assembly may be worn or damaged and should be replaced.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page