Siemens 6AV6288-1AB10-0AA0 SIMATIC ProTool
€ 1.995,00
The Siemens 6AV6288-1AB10-0AA0 is a software license package belonging to the SIMATIC ProTool configuration software family, developed by Siemens for programming and configuring HMI operator panels and text displays. This product is part of the SIMATIC HMI software portfolio and serves as a configuration tool used to create visualization projects for operator panels such as the OP, TP, and TD series. It enables engineers to design screens, configure tags, and define alarm and event handling for HMI devices.
The 6AV6288-1AB10-0AA0 variant is a runtime or configuration license edition of ProTool, designed to run on standard Windows-based engineering workstations. It supports communication with Siemens SIMATIC S5 and S7 PLCs via standard interfaces including MPI, PROFIBUS, and serial connections. The software provides tools for creating text-based and graphical operator interfaces, managing recipes, and configuring message systems for connected HMI hardware.
ProTool software is widely used in manufacturing, process automation, and machine building environments where SIMATIC HMI panels are deployed. It is particularly suited for retrofitting or maintaining legacy Siemens HMI installations that use older operator panel hardware such as the OP7, OP17, OP27, TP27, and similar devices. Engineers maintaining existing SIMATIC installations rely on this software to modify or extend existing HMI projects without migrating to newer platforms.
Technical Specifications
| Software Type | HMI Configuration / Engineering Software |
|---|---|
| Product Family | SIMATIC ProTool |
| Compatible HMI Devices | SIMATIC OP, TP, TD series operator panels |
| PLC Compatibility | SIMATIC S5, SIMATIC S7 |
| Communication Interfaces | MPI, PROFIBUS DP, Serial (RS-232) |
| Operating System | Windows (32-bit) |
| License Type | Single-user software license |
| Media Type | CD-ROM / License package |
| Language | Multi-language support |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1
- License not found or invalid license key detected during software startup
Verify the license key is correctly installed using the Siemens License Manager (SIMATIC Automation License Manager). Reinstall the license if necessary. - Event ID: 2
- Communication error between ProTool and the connected HMI panel during project download
Check the physical cable connection, verify the correct COM port or MPI adapter is selected in the project settings, and confirm the HMI panel is powered and in transfer mode. - Event ID: 3
- Project compilation error due to inconsistent tag configuration
Review the tag table for duplicate addresses or unsupported data types. Correct the configuration and recompile the project. - Event ID: 4
- Incompatible HMI device type selected for the current project
Verify the target HMI device type in the project properties matches the physical hardware. Adjust the device type setting and recompile. - Event ID: 5
- Transfer to HMI panel failed due to memory overflow
Reduce the project size by removing unused screens, images, or messages. Check the available memory specification of the target HMI device. - Event ID: 6
- Software installation error or missing runtime components
Reinstall the ProTool software package from the original installation media. Ensure all prerequisite Windows components are installed and the operating system is compatible.
Frequently Asked Questions
Which HMI panels are compatible with ProTool 6AV6288-1AB10-0AA0?
This software is compatible with SIMATIC operator panels including the OP7, OP17, OP27, OP37, TP27, TP37, and TD series text displays. It is intended for legacy Siemens HMI hardware and is not compatible with newer SIMATIC Comfort or Basic panels.
Which PLCs can be configured for communication using this software?
ProTool supports communication with SIMATIC S5 and SIMATIC S7 PLCs via MPI, PROFIBUS DP, and serial interfaces. The specific drivers available depend on the installed software version.
Is ProTool compatible with modern Windows operating systems?
ProTool is designed for older 32-bit Windows environments such as Windows XP and Windows 2000. It is generally not compatible with Windows 7 64-bit or later operating systems without virtualization.
Can existing ProTool projects be migrated to TIA Portal?
Siemens provides migration tools within TIA Portal to import ProTool projects, though manual rework is typically required due to differences in device support and functionality between the two platforms.
What is the difference between ProTool and WinCC flexible?
ProTool is an older generation HMI configuration software supporting legacy SIMATIC panels, while WinCC flexible is its successor offering support for a wider range of devices and more advanced functionality. Siemens recommends WinCC flexible or TIA Portal for new projects.
Troubleshooting
Software fails to start after installation and displays a license error
Check the Siemens Automation License Manager to verify whether a valid license is registered on the engineering PC. Confirm the license matches the installed software version.
Transfer or reinstall the correct license using the Siemens Automation License Manager. Ensure the license dongle or software license file is present and recognized by the system.
Project download to HMI panel fails with a communication error
Verify the cable type and connection between the PC and the HMI panel. Check that the correct interface (COM port or MPI adapter) is selected in the ProTool transfer settings and that the panel is set to transfer mode.
Replace the PC-to-HMI cable if faulty, select the correct interface in the software settings, and restart the transfer process with the panel in transfer mode.
ProTool will not install on the engineering workstation
Check the Windows operating system version and architecture. ProTool requires a 32-bit Windows environment and may fail on 64-bit systems or modern Windows versions.
Install ProTool on a compatible 32-bit Windows XP or Windows 2000 system, or use a virtual machine running a compatible 32-bit Windows environment.
Compiled project generates errors related to undefined tags or missing PLC connections
Open the tag table and PLC connection settings within ProTool. Check for missing or incorrectly configured PLC driver assignments and verify all tags reference valid PLC addresses.
Correct the PLC connection configuration, assign the appropriate communication driver, and ensure all tags are mapped to valid addresses within the PLC data range. Recompile the project after corrections.
HMI panel displays incorrect or outdated screen content after project download
Confirm that the full project was successfully transferred to the panel without errors during the download process. Check the panel memory status for available space.
Perform a complete panel memory reset if supported, then re-download the full project. Ensure no transfer errors occurred and that the panel firmware is compatible with the ProTool project version.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page