
Siemens 6AV6288-1AB20-0AA0 SIMATIC ProTool
€ 536,00
The Siemens 6AV6288-1AB20-0AA0 is a software license for SIMATIC ProTool, Siemens' configuration software for HMI (Human-Machine Interface) panels within the SIMATIC HMI product family. This part number corresponds to a specific ProTool software package used to create, configure, and manage visualization projects for operator panels such as the OP, TP, and MP series. It is part of Siemens' broader SIMATIC automation software ecosystem.
SIMATIC ProTool provides an engineering environment for developing HMI applications, including screen design, alarm management, recipe handling, and communication configuration. The software supports connectivity to SIMATIC S5 and S7 PLCs via standard interfaces such as MPI, PROFIBUS, and serial connections. It includes a library of pre-built function blocks and graphical elements to accelerate project development, and supports multiple language configurations for international deployments.
ProTool is primarily used in manufacturing and process automation environments where operator panels are deployed for machine control and monitoring. Typical applications include machine tools, packaging machinery, printing equipment, and general factory automation. It is suited for projects requiring a straightforward HMI configuration tool compatible with legacy and current Siemens SIMATIC controller platforms.
Technical Specifications
| Software Type | HMI Configuration / Engineering Software |
|---|---|
| Product Family | SIMATIC ProTool |
| Compatible HMI Devices | SIMATIC OP, TP, MP series operator panels |
| PLC Compatibility | SIMATIC S5, SIMATIC S7 |
| Communication Interfaces | MPI, PROFIBUS DP, Serial (RS-232/RS-422/RS-485) |
| Operating System | Windows (32-bit, version dependent) |
| License Type | Single-user software license |
| Certifications | CE |
Common Error Codes and Software Events
- Configuration Error
- Project configuration contains invalid or missing tag references, preventing compilation.
Open the project in ProTool and use the validation function to identify and correct all invalid tag or connection references before recompiling. - Communication Error
- No communication established between the HMI panel and the configured PLC.
Verify the communication interface settings (MPI address, baud rate, PROFIBUS address) in the ProTool project match the physical hardware configuration. - Transfer Error
- Project transfer to the HMI panel failed or was interrupted.
Check the transfer cable connection, confirm the correct COM port is selected in ProTool, and ensure the HMI panel is in transfer mode before retrying. - Version Mismatch
- The ProTool runtime version on the HMI panel is incompatible with the project software version.
Update the runtime software on the HMI panel to match the ProTool engineering software version used to create the project. - License Error
- Software license not found or has expired, preventing project compilation or transfer.
Verify the software license dongle is connected or the license is correctly installed on the engineering PC. Contact Siemens for license renewal if required. - Compilation Error
- Project compilation failed due to syntax errors or unsupported functions in the HMI configuration.
Review the error log in ProTool, correct all flagged configuration errors, and recompile the project.
Frequently Asked Questions
Which HMI panels are compatible with SIMATIC ProTool 6AV6288-1AB20-0AA0?
ProTool is compatible with the SIMATIC OP (Operator Panel), TP (Touch Panel), and MP (Multi Panel) series HMI devices. Compatibility depends on the specific software version included with this license.
Does ProTool support SIMATIC S7 PLC communication?
Yes, ProTool supports communication with SIMATIC S7 PLCs via MPI and PROFIBUS DP interfaces, as well as with older SIMATIC S5 controllers via serial connections.
Can ProTool projects be migrated to WinCC flexible or TIA Portal?
Siemens provides a migration tool within WinCC flexible that can import ProTool projects, allowing users to transition to the newer engineering environment. Some manual rework may be required after migration.
What operating system is required to run SIMATIC ProTool?
ProTool is designed for 32-bit Windows operating systems. It is not natively compatible with 64-bit Windows versions, so a 32-bit Windows environment or virtual machine may be required.
Is ProTool still actively supported by Siemens?
SIMATIC ProTool has reached end-of-life and is no longer actively developed by Siemens. WinCC flexible and TIA Portal WinCC are the recommended replacements for new projects.
Troubleshooting
ProTool software fails to install on the engineering PC
Check the Windows version and architecture. ProTool requires a 32-bit Windows environment and may not install on 64-bit systems without compatibility settings.
Install ProTool on a 32-bit Windows XP or Windows 7 (32-bit) system, or use a virtual machine running a compatible 32-bit Windows version.
Project transfer to HMI panel fails repeatedly
Verify the serial or MPI cable is correctly connected and the COM port selected in ProTool matches the physical port in use. Check that the HMI panel is set to transfer mode.
Replace the transfer cable if faulty, select the correct COM port in ProTool transfer settings, and restart the HMI panel in transfer mode before initiating the transfer again.
HMI panel displays communication fault after project download
Compare the PLC address, baud rate, and communication profile settings in the ProTool project against the actual PLC and network configuration.
Correct the communication parameters in the ProTool project to match the physical network settings, recompile, and re-transfer the project to the HMI panel.
ProTool license not recognized after PC replacement
The software license may be tied to a hardware dongle or a specific PC. Check whether the license dongle is present and recognized by the operating system.
Connect the original license dongle to the new PC. If a soft license was used, contact Siemens technical support to transfer the license to the new engineering PC.
Compiled project produces unexpected behavior on the HMI panel
Check the ProTool project for incorrect tag mappings, overlapping screen objects, or misconfigured alarm triggers that may cause runtime issues.
Use the ProTool simulation function to test the project before transfer, correct any identified logic or configuration errors, and re-transfer the validated project to the panel.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page


