Siemens 6AV6288-1AB00-0AA0 SIMATIC ProTool
€ 1.995,00
The Siemens 6AV6288-1AB00-0AA0 is a software license package for SIMATIC ProTool, Siemens' configuration and programming software for HMI (Human-Machine Interface) panels and operator devices. It belongs to the SIMATIC HMI software family and is used to create visualization projects for operator panels such as the OP, TP, and MP series. This part number represents a specific edition or upgrade of the ProTool engineering software, designed to work within the Siemens SIMATIC automation environment.
ProTool provides a graphical project engineering environment for configuring screens, alarms, tags, and communication connections to Siemens PLCs including S7-200, S7-300, and S7-400 series controllers. The software supports communication via MPI, PROFIBUS DP, and serial interfaces, enabling integration with a wide range of Siemens and third-party controllers. It includes libraries of standard function blocks, faceplates, and symbol sets to accelerate project development, and supports multi-language project configuration for international deployments.
ProTool software is used across a broad range of industrial sectors including manufacturing, process automation, food and beverage, automotive, and machine building. It is typically deployed by machine builders and system integrators who need to configure operator panels for local machine control and monitoring. The software is particularly suited for applications requiring straightforward HMI configuration without the complexity of full SCADA systems, making it a practical choice for standalone machine-level visualization tasks.
Technical Specifications
| Software Type | HMI Engineering / Configuration Software |
|---|---|
| Product Family | SIMATIC ProTool |
| Compatible HMI Devices | SIMATIC OP, TP, MP series operator panels |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, S5 |
| Communication Interfaces | MPI, PROFIBUS DP, Serial (RS-232) |
| License Type | Single-user software license |
| Operating System | Windows (version per release requirements) |
| Software Category | HMI project engineering tool |
| Language Support | Multi-language project configuration |
| Integration | SIMATIC Manager / STEP 7 environment |
Common Error Codes & System Events
- Error 1000
- License not found or invalid license key detected during software startup
Verify that the software license dongle or license file is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary. - Error 1200
- Communication error between ProTool and the target HMI device during project download
Check the physical connection cable between the PC and the HMI panel. Verify correct COM port or MPI adapter settings in the project transfer configuration. - Error 2001
- Project compilation failed due to inconsistent tag or screen configuration
Review the error log in the ProTool output window. Correct any undefined tags, missing connections, or invalid screen object references before recompiling. - Error 3010
- Target device not responding during online transfer
Ensure the HMI panel is powered on and in transfer mode. Verify baud rate and interface settings match between ProTool and the target device. - Error 4005
- Incompatible project version detected when opening an existing project file
Check the ProTool software version against the project file version. Upgrade the project using the ProTool migration wizard or install the correct software version. - Error 5100
- Insufficient memory on target HMI device for the compiled project
Reduce the number of screens, graphics, or alarm entries in the project. Check the memory usage indicator in ProTool and optimize image sizes and tag counts. - Error 6000
- PLC communication driver not found or not correctly configured
Verify that the correct communication driver for the target PLC is installed and selected in the project settings. Reinstall the driver package if necessary.
Frequently Asked Questions
Which HMI panels are compatible with ProTool 6AV6288-1AB00-0AA0?
ProTool is compatible with the SIMATIC OP (Operator Panel), TP (Touch Panel), and MP (Multi Panel) series of HMI devices from Siemens. Compatibility depends on the specific ProTool version included with this license.
What PLC families can be configured for communication in ProTool?
ProTool supports communication with SIMATIC S7-200, S7-300, S7-400, and S5 PLCs via MPI, PROFIBUS DP, and serial interfaces. Some third-party PLCs are also supported via serial drivers.
Is ProTool still supported by Siemens for new projects?
ProTool has been superseded by WinCC flexible and later TIA Portal WinCC. Siemens recommends migrating existing ProTool projects to WinCC flexible or TIA Portal for continued support and compatibility with newer hardware.
Can ProTool projects be migrated to WinCC flexible or TIA Portal?
Yes, Siemens provides migration tools within WinCC flexible to import ProTool projects. Some manual rework may be required depending on the complexity of the original project and the target platform.
What operating system is required to run ProTool?
ProTool requires a Windows-based PC; the specific Windows version depends on the ProTool release. Older versions of ProTool are typically compatible with Windows XP or Windows 2000 environments.
Troubleshooting
Software fails to start and reports a missing or invalid license
Open the Siemens Automation License Manager (ALM) and check whether a valid ProTool license is listed. Verify that the license dongle is connected or that the software-based license is correctly installed on the machine.
Transfer a valid license using ALM from a backup or license storage medium. If using a hardware dongle, ensure it is recognized by the operating system and that the dongle driver is installed correctly.
Project download to HMI panel fails with a communication error
Check the physical cable connection between the PC and the HMI panel. Verify the interface settings in ProTool (COM port, baud rate, MPI address) match the panel configuration.
Replace or reseat the communication cable. Confirm the HMI panel is in transfer mode. Adjust the interface parameters in ProTool transfer settings to match the panel and retry the download.
ProTool project compiles with errors referencing undefined tags
Review the compilation output log to identify which tags or screen objects are flagged. Cross-reference with the tag table to find missing or incorrectly named entries.
Correct all undefined tag references in the tag table and screen objects. Ensure all PLC variable addresses are valid and within the configured communication connection range, then recompile the project.
Existing project file cannot be opened and reports a version incompatibility
Check the ProTool version installed on the PC against the version used to create the project file. Older project files may not be directly compatible with newer ProTool installations.
Install the correct version of ProTool that matches the project file, or use the ProTool project upgrade function to convert the file to the current version. Back up the original project file before attempting conversion.
HMI panel displays incorrect or no data after project download
Verify the PLC communication settings in the ProTool project, including the MPI or PROFIBUS address, baud rate, and PLC variable addresses. Check that the PLC program is running and the correct data blocks are accessible.
Correct the communication parameters in the ProTool project to match the actual PLC configuration. Re-download the project to the panel and confirm the PLC is in RUN mode with the expected data available at the configured addresses.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page