
Siemens 6AV6245-1BC10-0BX1 SIMATIC MP 270B
€ 3.495,00
The Siemens 6AV6245-1BC10-0BX1 is a Multi Panel (MP) 270B belonging to the SIMATIC HMI family, designed for machine-level visualization and operator control in industrial automation environments. This panel features a 10.4-inch TFT color display and runs on the Windows CE operating system, providing a robust platform for SCADA and HMI applications. It is part of Siemens' established SIMATIC HMI panel range, offering reliable human-machine interface functionality for demanding industrial settings.
The MP 270B 6AV6245-1BC10-0BX1 is equipped with a resistive touch screen and function keys, allowing flexible operator interaction. It supports communication via MPI, PROFIBUS DP, and Ethernet interfaces, enabling integration with SIMATIC S7 PLCs and other automation systems. The panel provides onboard Flash memory for project storage and is configurable using Siemens WinCC flexible engineering software. Its fanless design and robust housing contribute to reliable operation in industrial conditions.
This panel is widely deployed in manufacturing, automotive, food and beverage, and process industries where a mid-range operator panel with color visualization is required. It is suitable for controlling and monitoring machinery such as packaging lines, conveyor systems, and process equipment. The combination of touch and key operation makes it adaptable to environments where gloved operation or precise input is necessary.
Technical Specifications
| Display Size | 10.4 inch |
|---|---|
| Display Type | TFT Color LCD |
| Display Colors | 256 colors |
| Display Resolution | 640 x 480 px (VGA) |
| Touch Technology | Resistive touchscreen |
| Operating System | Windows CE |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 25 W |
| Communication Interface | MPI, PROFIBUS DP, Ethernet (RJ45) |
| Memory | Flash memory (onboard) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI/PROFIBUS or Ethernet cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Restart both PLC and HMI panel. - Event ID: 10001
- Connection to PLC interrupted during runtime. The configured communication link has been lost.
Inspect physical cabling and connectors. Verify bus termination and address assignments. Check PLC operating state and reload HMI project if necessary. - Event ID: 20000
- Project download error. The project transfer from the engineering PC to the panel has failed.
Verify the transfer settings in WinCC flexible match the panel interface. Ensure the panel is in transfer mode. Check network or serial cable integrity. - Event ID: 40000
- Tag read/write error. The HMI panel cannot read from or write to a configured PLC tag.
Verify the tag address in the HMI project matches the actual PLC data block or memory address. Check PLC program for address conflicts. - Event ID: 50000
- System memory low. Available runtime memory on the panel is insufficient for current operations.
Reduce the number of active screens or objects. Archive or delete unnecessary data records and alarm logs. Consider optimizing the HMI project. - Event ID: 60000
- Internal device error or hardware fault detected on the panel.
Perform a panel restart. If the error persists, back up the project and perform a factory reset. Contact Siemens technical support if the fault recurs. - Event ID: 70000
- Alarm buffer overflow. The number of pending alarms exceeds the configured buffer capacity.
Acknowledge and clear active alarms. Increase the alarm buffer size in the WinCC flexible project settings and reload the project to the panel.
Frequently Asked Questions
Which engineering software is used to configure the MP 270B 6AV6245-1BC10-0BX1?
This panel is configured using Siemens WinCC flexible, which supports project creation, tag configuration, and project transfer to the panel via MPI, PROFIBUS, or Ethernet.
What communication interfaces are available on this panel?
The 6AV6245-1BC10-0BX1 supports MPI, PROFIBUS DP, and Ethernet (RJ45) interfaces, allowing direct connection to SIMATIC S7-300 and S7-400 PLCs as well as network-based systems.
Is this panel compatible with SIMATIC S7-1200 or S7-1500 PLCs?
The MP 270B is primarily designed for use with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. Compatibility with S7-1200 and S7-1500 via Ethernet may be limited and should be verified against the WinCC flexible version used.
What is the front panel protection rating of this unit?
The front panel of the 6AV6245-1BC10-0BX1 carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.
Can the MP 270B operate with both touch and key input?
Yes, the MP 270B 6AV6245-1BC10-0BX1 features both a resistive touchscreen and physical function keys, allowing flexible operator input including use with gloves.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify the supply is within the specified range and measure current draw. Inspect internal fuses if accessible.
Ensure the 24 V DC supply is stable and correctly wired. If the backlight has failed, the panel may require backlight or display replacement. If no power is detected internally, the power supply board may need to be replaced.
Panel does not communicate with the PLC
Verify the MPI or PROFIBUS address configured in the HMI project matches the physical bus address set on the panel. Check cable connections, bus termination, and that the PLC is in RUN mode.
Correct any address mismatches in WinCC flexible and reload the project. Replace or reseat the communication cable. Ensure bus termination resistors are correctly placed at both ends of the PROFIBUS or MPI segment.
Touchscreen does not respond or responds inaccurately
Check whether the touchscreen responds at all or only in certain areas. A miscalibrated or damaged resistive touch layer is a common cause of inaccurate input.
Perform a touchscreen recalibration through the panel's Control Panel settings in Windows CE. If calibration does not resolve the issue, the touchscreen overlay may need to be replaced.
Project transfer fails from engineering PC to panel
Confirm the panel is set to transfer mode (accessible via the Start Center on the panel). Verify the transfer interface and address settings in WinCC flexible match the panel configuration.
Switch the panel to transfer mode before initiating the download. Check the Ethernet or MPI/PROFIBUS cable and connection settings. Disable any firewall software on the engineering PC that may block the transfer.
Panel repeatedly restarts or freezes during operation
Check the supply voltage for instability or voltage drops under load. Inspect the project for memory-intensive operations or corrupted project data. Review the Windows CE event log if accessible.
Stabilize the 24 V DC power supply and ensure adequate current capacity. Reload a known-good project version to the panel. If the issue persists, perform a factory reset and reconfigure the panel from scratch.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page



