Siemens 6AV6244-1BC10-0KX1 MP 277
€ 3.495,00
The Siemens 6AV6244-1BC10-0KX1 is a Multi Panel (MP 277) belonging to the SIMATIC HMI family, designed for demanding machine-level visualization and operator control tasks. This panel features a 10.4-inch TFT display and runs on the Windows CE operating system, providing a robust and flexible platform for industrial human-machine interface applications. It is part of Siemens' established SIMATIC HMI panel range, which is widely deployed across process and discrete manufacturing environments.
The MP 277 10" Touch (6AV6244-1BC10-0KX1) is equipped with a resistive touchscreen interface and delivers a display resolution of 640 x 480 pixels (VGA) with 256 colors. It supports multiple communication interfaces including PROFIBUS DP and MPI, as well as Ethernet (TCP/IP) for integration into modern network architectures. The panel includes 12 MB of user memory for project data and is configurable using Siemens WinCC flexible engineering software. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The MP 277 is commonly used in machine building, automotive manufacturing, food and beverage processing, and packaging industries where reliable local HMI functionality is required. Its compatibility with SIMATIC S7 PLCs, including S7-300 and S7-400 series, makes it a natural fit for Siemens-based automation architectures. The panel's robust construction and wide operating temperature range make it suitable for installation in industrial control cabinets and harsh production environments.
Technical Specifications
| Display Size | 10.4 inch |
|---|---|
| Display Resolution | 640 x 480 pixels (VGA) |
| Display Colors | 256 colors |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 18 W |
| Communication Interface | PROFIBUS DP/MPI, Ethernet (RJ45), RS-422/RS-485 |
| User Memory | 12 MB |
| Operating System | Windows CE |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI MP 277 |
Common Error Codes & System Events
- Event ID: 040000
- Configuration error detected during startup; the project loaded on the panel contains configuration inconsistencies.
Re-transfer the project using WinCC flexible. Verify that the project was compiled without errors before transfer. - Event ID: 070000
- Communication error on MPI/PROFIBUS interface; connection to the PLC has been lost or cannot be established.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the configured PLC address matches the actual PLC settings. - Event ID: 080000
- Ethernet communication error; the panel cannot reach the configured network partner.
Verify IP address configuration on both the panel and the PLC. Check Ethernet cable and switch/hub connectivity. - Event ID: 100000
- Tag read/write error; a configured variable cannot be read from or written to the connected controller.
Check PLC program to ensure the referenced data blocks and addresses exist. Verify communication is active and the tag configuration is correct. - Event ID: 110000
- Project transfer error; the data transfer from the engineering PC to the panel was interrupted or failed.
Check the transfer cable or network connection. Ensure the panel is in transfer mode and retry the project download. - Event ID: 120000
- Internal memory error; insufficient user memory available to load the project.
Delete unused projects or data from the panel memory. Optimize the project size in WinCC flexible and re-transfer. - Event ID: 130000
- Recipe data error; recipe records could not be read or written correctly.
Check recipe configuration in WinCC flexible. Verify that the storage location (internal memory or memory card) is accessible and not full.
Frequently Asked Questions
Which engineering software is used to configure the MP 277 (6AV6244-1BC10-0KX1)?
The MP 277 is configured using Siemens WinCC flexible 2008 or later. Projects are compiled on a PC and transferred to the panel via Ethernet, USB, or MPI/PROFIBUS connection.
Which Siemens PLCs are compatible with this panel?
The MP 277 is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 series PLCs via MPI, PROFIBUS DP, or Ethernet interfaces. It also supports communication with third-party controllers via serial protocols.
What is the input voltage requirement for the 6AV6244-1BC10-0KX1?
The panel requires a 24 V DC supply voltage. The permissible voltage range is typically 19.2 V DC to 28.8 V DC.
Is the MP 277 front panel rated for washdown or dusty environments?
Yes, the front face of the MP 277 carries an IP65 protection rating, making it suitable for environments with dust and water spray. The rear of the unit is rated IP20.
Can the MP 277 store recipes and log data internally?
Yes, the MP 277 supports recipe management and data logging. Data can be stored in the panel's internal user memory (12 MB) or on an external memory card inserted into the panel's card slot.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check that the voltage is within the 19.2–28.8 V DC range. Inspect the internal fuse if accessible.
Correct the supply voltage if out of range. If the supply is correct and the display remains blank, the backlight or internal power supply board may be faulty and require replacement.
Panel does not communicate with the PLC via PROFIBUS or MPI
Check the PROFIBUS/MPI cable for continuity and correct pin assignment. Verify bus termination is active at both ends of the network. Confirm the PLC address configured in the project matches the physical PLC setting.
Replace or re-seat the communication cable. Enable bus termination at the correct nodes. Correct the PLC address in the WinCC flexible project and re-transfer to the panel.
Touchscreen does not respond or registers incorrect touch positions
Check whether the touchscreen surface is clean and free of moisture or debris. Access the Windows CE control panel to run the touchscreen calibration utility.
Clean the touchscreen surface with a soft, dry cloth. Perform a touchscreen recalibration via the Windows CE system settings. If the issue persists, the resistive touch overlay may require replacement.
Project transfer from PC to panel fails repeatedly
Verify the transfer mode is active on the panel (accessible via the Start Center on boot). Check the Ethernet or USB cable connection between the PC and panel. Confirm the IP address or transfer settings match in WinCC flexible.
Restart the panel and select Transfer mode from the Start Center. Re-check network or cable connections and retry the transfer. Temporarily disable PC firewall software that may be blocking the transfer port.
Panel displays 'No connection to PLC' alarm during operation
Check the physical communication link (Ethernet cable, PROFIBUS connector). Verify the PLC is powered and running. Review the connection parameters in the WinCC flexible project for correct IP address or PROFIBUS address.
Restore the physical connection and confirm the PLC is in RUN mode. If using Ethernet, ping the PLC from a PC on the same network to verify reachability. Correct any mismatched address parameters and re-transfer the project.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page