• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-3LP40-0KB2 MP 377
    Awaiting product image

    Siemens 6AV6146-3LP40-0KB2 MP 377

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6146-3LP40-0KB2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-3LP40-0KB2 is a Multi Panel (MP 377) belonging to the SIMATIC HMI family, designed for high-performance human-machine interface applications. This panel features a 15-inch widescreen TFT display and is part of the MP 377 series, which represents Siemens' advanced panel line for demanding industrial visualization tasks. It operates as a standalone HMI device capable of running WinCC flexible runtime environments.

    The MP 377 15" Touch (6AV6146-3LP40-0KB2) is equipped with a resistive touchscreen and delivers a display resolution of 1024 x 768 pixels with 64,000 colors. It features a 32 MB user memory for project data and supports multiple communication interfaces including PROFIBUS DP, PROFINET/Ethernet (RJ45), USB, and a serial RS-422/RS-485 interface. The panel runs on a Windows CE 5.0 operating system and includes an integrated CF card slot for additional storage. It operates on a 24 V DC supply and is rated to IP65 on the front face.

    The MP 377 is widely deployed in machine building, automotive manufacturing, process industries, and water/wastewater treatment plants where large-format visualization and robust operator control are required. Its multi-protocol communication capability makes it suitable for integration into both SIMATIC S7 PLC environments and third-party controller systems. The panel's industrial-grade construction and broad connectivity options make it a reliable choice for complex SCADA and HMI applications.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 40 W
    User Memory 32 MB
    Operating System Windows CE 5.0
    Communication Interface PROFIBUS DP, PROFINET/Ethernet (RJ45), USB, RS-422/RS-485
    Storage Slot CompactFlash (CF) card slot
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
    Check PROFIBUS or Ethernet cable connections and termination resistors. Verify PLC is powered and running. Confirm communication parameters (address, baud rate) match on both devices.
    Event ID: 10001
    Tag read error. The HMI panel cannot read the value of a configured tag from the PLC.
    Verify the tag address exists in the PLC program. Check that the data block or memory area referenced is present and accessible. Confirm communication link is active.
    Event ID: 10002
    Tag write error. The HMI panel cannot write a value to the configured PLC tag.
    Check that the target PLC address is not write-protected. Verify the tag configuration in WinCC flexible. Ensure the PLC is in RUN mode and accepting write requests.
    Event ID: 20000
    Project transfer error. A project download to the panel has failed or been interrupted.
    Check the transfer cable or network connection. Ensure WinCC flexible runtime is stopped before transfer. Verify sufficient free memory on the panel and retry the transfer.
    Event ID: 40000
    System memory low. Available runtime memory on the panel is critically low.
    Reduce the number of active screens or logged data. Delete unnecessary files from the CF card. Consider reducing project complexity or increasing CF card storage.
    Event ID: 50000
    CF card not found or removed during operation. The CompactFlash card is missing or has been ejected while the system is running.
    Re-insert the CF card and restart the panel. Ensure the CF card is properly seated. Do not remove the CF card during panel operation.
    Event ID: 70000
    Backup/restore error. A backup or restore operation of the panel project has failed.
    Check that the CF card has sufficient free space. Verify the CF card is not write-protected. Retry the backup/restore operation using ProSave or WinCC flexible.

    Frequently Asked Questions

    What software is used to configure and program the MP 377 panel?

    The MP 377 (6AV6146-3LP40-0KB2) is configured using Siemens WinCC flexible 2008 or later. Projects are transferred to the panel via Ethernet, USB, or serial connection using the ProSave tool or directly from WinCC flexible.

    Which PLC systems are compatible with the MP 377?

    The MP 377 supports communication with Siemens SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via PROFIBUS DP or PROFINET/Ethernet. It also supports third-party controllers through serial drivers and OPC connections.

    What is the supply voltage for the 6AV6146-3LP40-0KB2?

    The panel requires a 24 V DC power supply, typically in the range of 19.2 V DC to 28.8 V DC, connected via the rear terminal block.

    Can the MP 377 be used as a PROFIBUS master or slave?

    The MP 377 operates as a PROFIBUS DP slave for communication with a SIMATIC PLC acting as the DP master. It does not function as a PROFIBUS DP master.

    What is the front panel protection rating of the 6AV6146-3LP40-0KB2?

    The front face of the MP 377 is rated IP65, making it suitable for panel-mount installations where protection against dust and water jets is required. The rear of the unit is rated IP20.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the rear power terminal. Check that the voltage is within the 19.2–28.8 V DC range. Inspect the internal fuse and power connector for damage.

    Correct the supply voltage if out of range. Replace the internal fuse if blown. If the backlight has failed, the display panel or inverter board may require replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Check whether the touchscreen is physically damaged or contaminated. Attempt to recalibrate the touch input via the panel's Start Center or Control Panel settings in Windows CE.

    Clean the touchscreen surface with a soft, dry cloth. Perform a touchscreen recalibration from the Start Center. If calibration fails repeatedly, the resistive touch layer may be worn and the display assembly should be replaced.

    Panel fails to communicate with the PLC after project download

    Verify the IP address or PROFIBUS address configured in the WinCC flexible project matches the panel's actual network settings. Check physical cable connections and switch/hub status.

    Correct the communication parameters in the project and re-download. Ensure the Ethernet cable is connected to the correct port and that the network switch is operational. Test with a direct cable connection to isolate network issues.

    Panel reboots repeatedly or freezes during operation

    Check for overheating by verifying the ambient temperature is within the 0–50 °C operating range. Inspect the CF card for errors and check available memory. Review the project for script errors or memory leaks.

    Improve ventilation around the panel. Replace a faulty or full CF card. Simplify the project if memory usage is excessive. Update the panel firmware to the latest version using ProSave.

    Project transfer fails or is rejected by the panel

    Confirm that the WinCC flexible version used to create the project is compatible with the panel's firmware version. Check that the transfer mode is enabled in the panel's Start Center and that the correct transfer channel is selected.

    Enable transfer mode on the panel via the Start Center before initiating the download. Match the WinCC flexible project version to the panel firmware. Update panel firmware via ProSave if a version mismatch is confirmed.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart