• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-3LP40-0KC2 MP 377
    Awaiting product image

    Siemens 6AV6146-3LP40-0KC2 MP 377

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6146-3LP40-0KC2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-3LP40-0KC2 is a Multi Panel (MP 377) belonging to the SIMATIC HMI family, designed for demanding visualization and operator control tasks in industrial automation environments. This panel features a 15-inch TFT display and runs on the Windows CE operating system, making it a high-performance operator panel suitable for complex process visualization. It is part of Siemens' established SIMATIC HMI panel portfolio, which is widely deployed across a broad range of industrial sectors.

    The MP 377 15" Touch variant (6AV6146-3LP40-0KC2) is equipped with a resistive touchscreen interface and delivers a display resolution of 1024 x 768 pixels (XGA) with 64,000 colors. It supports multiple communication interfaces including PROFIBUS DP, PROFINET/Ethernet (RJ45), USB, and a serial RS-422/RS-485 interface, enabling flexible integration into existing automation architectures. The panel includes 12 MB user memory for project data and is powered by a 24 V DC supply. Its robust industrial-grade housing is rated IP65 on the front face, providing protection against dust and water ingress in harsh environments.

    The SIMATIC MP 377 is commonly used in machine building, automotive manufacturing, food and beverage processing, chemical plants, and water treatment facilities. Its large display area and touch operation make it well suited for complex HMI applications requiring detailed process graphics, trend displays, alarm management, and recipe handling. The panel's compatibility with Siemens SIMATIC S7 PLCs and WinCC flexible engineering software makes it a natural choice for Siemens-based automation systems.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    User Memory 12 MB
    Communication Interface PROFIBUS DP, PROFINET/Ethernet (RJ45), USB, RS-422/RS-485
    Operating System Windows CE 5.0
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI MP 377

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC or controller. The configured connection cannot be established.
    Check PROFIBUS or Ethernet cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Restart both the PLC and the HMI panel.
    Event ID: 10001
    Connection to the PLC was interrupted during runtime operation.
    Inspect physical communication cables for damage. Verify network settings and PLC program is running. Re-establish the connection via the HMI Start Center if necessary.
    Event ID: 20000
    Tag read error. The HMI panel cannot read a configured tag from the PLC.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory area. Check that the PLC program contains the referenced data area.
    Event ID: 20001
    Tag write error. The HMI panel cannot write a value to the configured PLC tag.
    Check write permissions for the tag in the PLC program. Ensure the data block is not write-protected and the tag address is correct in the HMI project.
    Event ID: 40000
    Project download error. Transfer of the HMI project from the engineering PC to the panel failed.
    Verify the transfer cable or Ethernet connection between the PC and panel. Ensure the panel is in Transfer mode via the Start Center. Check that WinCC flexible version is compatible with the panel firmware.
    Event ID: 50000
    System memory low. Available memory on the panel is insufficient to load or run the project.
    Reduce project size by optimizing graphics and removing unused elements. Clear the panel memory via the Start Center before reloading the project.
    Event ID: 70000
    Firmware update error. The firmware update process was interrupted or failed.
    Restart the panel and attempt the firmware update again using the correct firmware version for the MP 377 from the Siemens support portal. Ensure stable power supply during the update.
    Event ID: 110000
    Recipe data error. A recipe record could not be read from or written to the configured storage location.
    Check the recipe configuration in WinCC flexible. Verify the storage medium (internal memory or external USB/CF card) is available and not full or corrupted.

    Frequently Asked Questions

    What engineering software is required to program the MP 377 (6AV6146-3LP40-0KC2)?

    The MP 377 is programmed using Siemens WinCC flexible 2008 or later. It is not compatible with TIA Portal WinCC Advanced without a migration step.

    Which PLCs are compatible with the SIMATIC MP 377?

    The MP 377 is compatible with Siemens SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via PROFIBUS DP or Ethernet/PROFINET. Third-party PLCs can also be connected via the serial RS-422/RS-485 interface using supported drivers.

    What communication interfaces does the 6AV6146-3LP40-0KC2 support?

    This panel supports PROFIBUS DP (up to 12 Mbit/s), PROFINET/Industrial Ethernet via RJ45, two USB ports (host and device), and a serial RS-422/RS-485 interface.

    Is the front panel of the MP 377 rated for washdown or dusty environments?

    Yes, the front face of the MP 377 is rated IP65, providing full protection against dust ingress and protection against water jets, making it suitable for use in washdown and dusty industrial environments.

    Can the MP 377 display be used with a keyboard or mouse?

    Yes, the MP 377 includes USB host ports that support the connection of an external USB keyboard and USB mouse for operator input in addition to the touchscreen.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that polarity is correct and voltage is within the 19.2–28.8 V DC tolerance range. Inspect the internal fuse if accessible.

    Correct any wiring errors or supply voltage issues. If the supply is confirmed good and the display remains blank, the backlight inverter or internal power supply board may require replacement or professional repair.

    Touchscreen does not respond or registers incorrect touch positions

    Check whether the touchscreen is physically damaged or contaminated. Attempt a touchscreen recalibration via the Windows CE Control Panel accessible through the Start Center.

    Clean the touchscreen surface with a soft cloth. Perform a touchscreen calibration in the Control Panel. If calibration does not resolve the issue, the resistive touch layer may be worn or damaged and the panel may require a display assembly replacement.

    HMI project fails to transfer from engineering PC to the panel

    Verify the panel is set to Transfer mode via the Start Center. Check the Ethernet or USB transfer cable connection. Confirm the IP address settings on both the PC and the panel are on the same subnet.

    Set the correct transfer channel in WinCC flexible project settings. Disable any PC firewall temporarily during transfer. Ensure the firmware version on the panel is compatible with the WinCC flexible version being used.

    Panel repeatedly reboots or freezes during runtime

    Check the supply voltage for stability and ripple. Inspect the project for memory overload or corrupted project data. Review system event logs accessible via the Start Center for specific event IDs.

    Ensure the power supply is stable and adequately rated (minimum 2.5 A at 24 V DC). Reload the HMI project after clearing panel memory. If the issue persists, update the panel firmware to the latest version available from Siemens support.

    Communication loss between the MP 377 and the PLC during operation

    Check PROFIBUS cable termination and connector integrity. For Ethernet connections, verify switch/hub port status and cable condition. Confirm PLC is in RUN mode and the communication parameters match the HMI project configuration.

    Replace damaged cables or connectors. Verify PROFIBUS termination resistors are enabled only at the two physical ends of the bus. Correct any mismatched baud rate or address settings in both the PLC and the WinCC flexible project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart