• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV5040-1BF41-0BA0 SIMATIC OP 40
    Awaiting product image

    Siemens 6AV5040-1BF41-0BA0 SIMATIC OP 40

    € 1.995,00

    Reset
    Clear
    SKU: 6AV5040-1BF41-0BA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV5040-1BF41-0BA0 is an operator panel (OP 40) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a monochrome display with function keys for process visualization and operator control, and is part of Siemens' classic OP series of operator panels. It is intended for use with SIMATIC S5 and S7 programmable logic controllers via serial communication interfaces.

    The OP 40 features a built-in LCD display and a comprehensive keypad layout including function keys, numeric keys, and system keys that allow operators to navigate screens, enter values, and acknowledge alarms without a touchscreen. It communicates with PLCs using the MPI or PROFIBUS-DP protocol as well as point-to-point serial interfaces, and is configured using Siemens ProTool software. The unit operates on a 24 V DC supply and is designed for panel front mounting with an IP65 protection rating on the front face.

    The SIMATIC OP 40 is widely used in manufacturing, process control, and machine automation applications where a robust, keypad-operated interface is preferred over touchscreen solutions. It is particularly suited to environments with high vibration or where operators wear gloves, making direct key input more reliable. Industries such as automotive manufacturing, food and beverage processing, and general machine building have historically deployed this panel for local operator control stations.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 5.7 inch
    Input Voltage 24 V DC
    Protection Rating (Front) IP65
    Communication Interface MPI, PROFIBUS-DP, Point-to-Point (RS-232/RS-422/RS-485)
    Configuration Software Siemens ProTool
    PLC Compatibility SIMATIC S5, SIMATIC S7
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 70 °C
    Mounting Panel front mounting
    Certifications CE, UL
    Series SIMATIC OP (Classic HMI)

    Common Error Codes & System Events

    System Error 1
    Communication error between the OP 40 and the connected PLC. The panel cannot establish or maintain a connection.
    Check the communication cable and connector integrity. Verify the MPI or PROFIBUS address settings on both the OP and the PLC. Ensure the baud rate is correctly configured on both devices.
    System Error 2
    Configuration data on the panel is missing or corrupted. The panel cannot load the project.
    Re-download the project from ProTool to the operator panel. Check the serial download cable and connection. Ensure the correct panel type is selected in the ProTool project.
    System Error 3
    Internal memory error detected. The panel's flash memory or RAM may be faulty.
    Perform a factory reset and re-download the project. If the error persists, the internal memory or main board may require replacement.
    System Error 4
    Power supply voltage is outside the permissible range. The 24 V DC supply is too low or too high.
    Measure the supply voltage at the panel's power connector. Ensure the supply is within the specified 24 V DC tolerance range. Check for loose connections or an undersized power supply.
    System Error 5
    Watchdog timeout. The panel's processor has not responded within the expected time, causing a watchdog reset.
    Restart the panel. If the fault recurs frequently, check for excessive CPU load caused by a large or complex project. A hardware fault on the main board may require repair or replacement.
    PLC Connection Timeout
    The panel has lost communication with the PLC and is displaying a connection timeout message on screen.
    Verify the PLC is powered and in RUN mode. Check all communication cables and termination resistors on the PROFIBUS or MPI network. Confirm the PLC address in the panel project matches the physical PLC configuration.
    Recipe/Data Error
    A recipe or data record cannot be read or written correctly, often due to a mismatch between the panel project and PLC data blocks.
    Verify that the data block addresses configured in ProTool match the actual data blocks in the PLC program. Re-download the project and test recipe operations again.

    Frequently Asked Questions

    What PLC families are compatible with the SIMATIC OP 40 (6AV5040-1BF41-0BA0)?

    The OP 40 is compatible with Siemens SIMATIC S5 and S7 PLC families via MPI, PROFIBUS-DP, or point-to-point serial interfaces. Third-party PLCs may also be supported depending on the available driver in ProTool.

    What software is used to configure and program the OP 40?

    The OP 40 is configured using Siemens ProTool, which is the classic configuration software for the SIMATIC OP and TD series panels. WinCC flexible does not support this older panel generation.

    What is the supply voltage for the 6AV5040-1BF41-0BA0?

    The panel requires a 24 V DC power supply. The supply must be within the specified tolerance range to ensure reliable operation.

    Does the OP 40 have a touchscreen?

    No, the OP 40 is a keypad-operated panel and does not feature a touchscreen. Operator input is performed via function keys, numeric keys, and system keys on the front panel.

    What is the front panel protection rating of the OP 40?

    The front panel of the OP 40 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel installation.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector using a multimeter. Inspect the internal fuse if accessible. Verify that the supply polarity is correct.

    Restore the supply voltage to within the specified 24 V DC range. Replace any blown internal fuse with the correct rating. If the display backlight has failed, the backlight or display assembly may require replacement.

    Panel displays 'No Connection' or communication error to PLC

    Verify the communication cable between the OP 40 and the PLC is correctly wired and undamaged. Check the MPI or PROFIBUS address configured in the panel project against the PLC's actual address. Inspect termination resistors on the bus.

    Replace or reseat the communication cable. Correct the address settings in the ProTool project and re-download. Ensure bus termination is active only at the two physical ends of the network.

    Project cannot be downloaded to the panel

    Check the download cable connection between the PC and the OP 40. Verify that the correct COM port and baud rate are selected in ProTool. Confirm the panel is in transfer mode.

    Place the panel in transfer mode by navigating to the system menu. Use a known-good Siemens download cable. Reinstall the ProTool software driver if the COM port is not recognized by the PC.

    Function keys do not respond or produce incorrect actions

    Check whether the keypad membrane is physically damaged or contaminated. Verify the key assignments in the ProTool project are correctly configured and the project has been fully downloaded.

    Clean the keypad surface. If keys are physically damaged, the keypad membrane assembly requires replacement. Re-download the project to ensure the latest key assignments are active on the panel.

    Panel restarts repeatedly or enters a boot loop

    This may indicate corrupted project data in flash memory or a hardware fault on the main board. Attempt to enter the panel's system menu during startup to access the transfer or service mode.

    Perform a complete project re-download via ProTool. If the panel cannot be accessed, a factory reset may be required. Persistent boot loops after re-download indicate a main board fault requiring repair or component replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart