• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV5040-1BF41-0AA0 SIMATIC OP 40
    Awaiting product image

    Siemens 6AV5040-1BF41-0AA0 SIMATIC OP 40

    € 2.441,00

    Reset
    Clear
    SKU: 6AV5040-1BF41-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV5040-1BF41-0AA0 is an Operator Panel (OP 40) belonging to the SIMATIC HMI family, designed for operator control and monitoring in industrial automation environments. This unit provides a compact, panel-mounted interface for machine-level visualization and process control. It is part of Siemens' established SIMATIC HMI line, offering reliable human-machine interaction for a wide range of automation tasks.

    The OP 40 features a monochrome LCD display with a resolution suited for text and simple graphic representation, along with a membrane keypad for operator input. It communicates with Siemens SIMATIC S5 and S7 PLCs via the MPI or PROFIBUS DP interface, enabling direct integration into existing Siemens automation networks. The panel supports configuration via Siemens ProTool software and provides alarm management, recipe handling, and process value display functions. The unit is designed for 24 V DC supply and is built to withstand typical industrial environmental conditions.

    The SIMATIC OP 40 is commonly used in machine building, manufacturing automation, and process control applications where a robust, dedicated operator interface is required at the machine level. It is well suited for industries such as automotive, food and beverage, packaging, and general manufacturing, where operators need a reliable panel for status monitoring, parameter entry, and alarm acknowledgment. Its compatibility with the SIMATIC S5 and S7 controller families makes it a practical choice for both legacy system maintenance and integrated automation solutions.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 5.7 inch
    Keypad Membrane keypad with function keys
    Input Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    PLC Compatibility SIMATIC S5, SIMATIC S7
    Configuration Software Siemens ProTool
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Series SIMATIC HMI OP 40

    Common Error Codes & System Events

    System Error 1
    Communication error between OP 40 and connected PLC. Connection to the controller has been lost or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings and baud rate configuration in ProTool match the controller settings.
    System Error 2
    Configuration data on the operator panel is invalid or corrupted.
    Re-download the project configuration from the ProTool engineering software to the OP 40. Ensure the correct project file is used for this panel.
    System Error 3
    Overflow of the alarm buffer. More alarms have been generated than the panel buffer can store.
    Acknowledge and clear pending alarms. Review alarm configuration to reduce unnecessary alarm triggers and increase buffer size in ProTool if possible.
    System Error 4
    Recipe data error. A recipe record could not be read or written correctly.
    Check recipe configuration in ProTool. Verify that recipe data areas in the PLC data blocks are correctly mapped and accessible.
    System Error 5
    Internal panel memory error detected during self-test or operation.
    Perform a panel reset. If the error persists, re-download the project. If the fault continues, the panel may require hardware repair or replacement.
    System Error 6
    Incorrect or incompatible firmware version detected on the operator panel.
    Update the panel firmware to the version compatible with the ProTool project version being used. Refer to Siemens compatibility documentation.
    System Error 7
    Power supply voltage out of acceptable range. The 24 V DC supply is below or above tolerance.
    Measure the supply voltage at the panel power connector. Ensure the supply is within the specified 24 V DC tolerance range and check for loose connections or power supply faults.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC OP 40 (6AV5040-1BF41-0AA0)?

    The OP 40 is compatible with Siemens SIMATIC S5 and S7 series PLCs, communicating via MPI or PROFIBUS DP interfaces. Correct addressing and baud rate settings must be configured in both the panel and the controller.

    What software is used to configure the OP 40?

    The OP 40 is configured using Siemens ProTool software. Projects are created on a PC and downloaded to the panel via the appropriate programming cable.

    What is the supply voltage for the 6AV5040-1BF41-0AA0?

    The panel requires a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance to avoid communication or operational errors.

    What is the front panel protection rating of the OP 40?

    The OP 40 provides an IP65 protection rating at the front panel when correctly installed in a panel cutout, making it suitable for environments with dust and water spray exposure.

    Can the OP 40 be used as a replacement in legacy SIMATIC installations?

    Yes, the OP 40 is commonly used as a replacement or spare in existing SIMATIC S5 and S7 installations. The original ProTool project file should be available to re-download the configuration to the replacement unit.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals of the panel. Inspect the supply cable and connector for damage or loose connections.

    Restore correct 24 V DC supply. If voltage is confirmed correct and the display remains blank, inspect the internal fuse and replace if blown. If the fault persists, the panel may require internal repair.

    No communication with PLC after startup

    Verify MPI or PROFIBUS DP cable connections at both the panel and PLC. Check that the bus address and baud rate configured in ProTool match the PLC settings. Inspect termination resistors at both ends of the bus.

    Correct any address or baud rate mismatches in the ProTool project and re-download. Replace damaged cables or connectors. Ensure bus termination is correctly applied at both ends of the network segment.

    Panel displays configuration or project errors on startup

    The project data stored in the panel may be corrupted or incompatible with the current firmware version. Connect a PC with ProTool and attempt to re-download the project.

    Re-download the correct ProTool project to the panel. If firmware incompatibility is suspected, update the panel firmware to the appropriate version before downloading the project.

    Operator keys not responding or responding incorrectly

    Inspect the membrane keypad for physical damage, contamination, or wear. Test individual keys in the panel's diagnostic or test mode if available.

    Clean the keypad surface carefully. If individual keys are damaged or non-functional, the membrane keypad assembly may need to be replaced as part of a panel repair.

    Alarms are not displayed or acknowledged correctly

    Check the alarm configuration in the ProTool project, including the PLC data areas mapped to alarm bits. Verify that the PLC program is correctly setting and resetting alarm bits.

    Correct the alarm bit mapping in the ProTool project and re-download. Ensure the PLC program logic correctly drives the alarm data areas. Clear any overflowed alarm buffers by acknowledging all pending alarms.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart